Effects of Use of the Iodine Contrast Medium on Gamma Camera Imaging (요오드 조영제 사용이 감마카메라 영상에 미치는 영향)

  • Pyo, Sung-Jae;Cho, Yun-Ho;Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.557-564
    • /
    • 2016
  • Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficient in an SPECT/CT attenuation correction will be considered herein. For experimental materials used $^{99m}TcO_4$ 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of $^{99m}TcO_4$. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope $^{99m}TcO_4$ and the saline solution were mixed. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and saline solution, the mean counting rate without correction by the CT absorption coefficient is $182{\pm}26counts$, while the counting rate with correction by the CT absorption coefficient is $531.3{\pm}34counts$. In the tomography for mixing of the radioactive isotope $^{99m}TcO_4$ and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were $166{\pm}29$, $158.3{\pm}17$, $154{\pm}36$, and $150{\pm}33counts$ depending on the densities of the contrast medium, while the mean values after attenuation correction were $515{\pm}03$, $503{\pm}10$, $496{\pm}31$, and $488.7{\pm}33counts$, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of dignosis.

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Utility of Acetazolamide-Enhanced Brain Perfusion SPECT in Predicting Outcome of the Patients with Aneurysmal Subarachnoid Hemorrhage (뇌동맥류파열에 의한 지주막하 출혈환자의 예후평가에 있어서 아세타졸아미드 부하 뇌혈류 SPECT의 유용성)

  • Choi, Yun-Young;Kim, Jae-Min;Kim, Kwang-Myung;Choe, Il-Seung;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.241-250
    • /
    • 2001
  • Purpose: Vasospasm is a complication of aneurysmal subarachnoid hemorrhage (aSAH). We assessed the role of acetazolamide-enhanced brain perfusion SPECT (ACZ-SPECT) with Tc-99m ECD for predicting the prognosis of patients with aSAH. Materials and methods: Two SPECT studios (baseline with 740 MBq and ACZ-SPECT with 1480 MBq) with image subtraction were performed in 21 patients with aSAH. All patients had brain CT and angiogram. Vasoreactivity on ACZ-SPECT, perfusion defect on baseline SPECT, and vasospasm on angiogram were correlated with Hunt-Hess grading, extent of SAH (unilateral or bilateral) on CT, and clinical outcome. Vasoreactivity was considered decreased when cerebral/cerebellar uptake ratio difference from baseline SPECT to ACZ-SPECT was greater than 2SD of normal control values. Results: Decreased vasoreactivity was observed in 38% (8/21), perfusion defect in 81% (17/21), and vasospasm in 38% (8/21). The preserved vasoreactivity group showed better outcome scale (92%, 12/13) and the decreased vasoreactivity group showed poorer outcome scale (62.5%, 5/8) (p=0.014). Extensive SAH was more frequently seen in the decreased vasoreactlvlty group (87.5%, 7/8) than in the preserved vasoreactivity group (30.7%, 4/13)(p=0.017). The perfusion defect and vasospasm did not show good correlation with outcome scale, extent of SAH, and Hunt-Hess grading (p=ns). Vasoreactivity represented the patient's outcome better than the vasospasm in all of the vasoreactivity/vasospasm-mismatched cases (6 cases). Conclusions: Our data show that decreased vasoreactivity on ACZ-SPECT does not always represent vasospastic condition. But patients with decreased vasoreactivity reveal poorer outcome than patients with angiographic vasospasm do. Therefore ACZ-SPECT is a valuable, noninvasive test for predicting the prognosis of patients with aSAH.

  • PDF

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Development of Immobilization Devices for Patients with Pelvic Malignancies and a Feasibility Evaluation during Radiotherapy (골반부 암 환자를 위한 고정기구 개발 및 방사선치료 시 효용성 평가)

  • Park, Jong-Min;Park, Yang-Kyun;Cho, Woong;Park, Charn-Il;Ha, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.134-144
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: Immobilization devices that improve the setup reproducibility of pelvic cancer patients and that provide comfort to patients during radiotherapy were designed and the feasibility of the devices was evaluated. $\underline{Materials\;and\;Methods}$: A customized device was designed to immobilize a knee, thigh, and foot of a patient. Sixty-one patients with prostate cancer were selected and were divided into two groups-with or without devices. The setup errors were measured with respect to bony landmarks. The difference between digitally reconstructed radiographs (DRR) and simulation films, and the differences between DRR and portal films were measured. $\underline{Results}$: The left-right (LR), anterior-posterior (AP) and craniocaudal (CC) errors between the DRR and simulation films were $1.5{\pm}0.9\;mm$, $3.0{\pm}3.6\;mm$, and $1.6{\pm}0.9\;mm$, respectively without devices. The errors were reduced to $1.3{\pm}1.9\;mm$, $1.8{\pm}1.5\;mm$ and $1.1{\pm}1.1\;mm$, respectively with the devices. The errors between DRR and portal films were $1.6{\pm}1.2\;mm$, $4.0{\pm}4.1\;mm$, and $4.2{\pm}5.5\;mm$, respectively without the devices and were reduced to $1.0{\pm}1.8\;mm$, $1.2{\pm}0.9\;mm$, and $1.2{\pm}0.8\;mm$, respectively, with the devices. The standard deviations among the portal films were 1.1 mm, 2.1 mm, and 1.0 mm at each axis without the devices and 0.9 mm, 1.6 mm and 0.8 mm with the devices. The percentage of setup errors larger than 3 mm and 5 mm were significantly reduced by use of the immobilization devices. $\underline{Conclusion}$: The designed devices improved the setup reproducibility for all three directions and significantly reduced critical setup errors.

Is $^{99m}Tc$-MDP Mammoscintigraphy Useful in Patients with Breast Mass Lesions? ($^{99m}Tc$-MDP 유방 스캔은 유방 종괴의 감별진단에 임상적인 유용성이 있는가?)

  • Park, Seok-Gun;Lee, Yeon-Hee;Rhyu, Jin-Woo;You, Sun-Mee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.151-160
    • /
    • 1998
  • Purpose: Piccolo et al. advocated the usefulness of $^{99m}Tc$-MDP breast scan in differential diagnosis of breast mass with high accuracy. But there are little or no follow-up studies about it as we know. We studied $^{99m}Tc$-MDP uptake pattern and lesion/background ratio in patients complaining palpable breast lesions to evaluate the clinical usefulness of $^{99m}Tc$-MDP scan. Materials and Methods: Total 34 patients were studied with physical examination, mammo-gram and $^{99m}Tc$-MDP scan prospectively. Anteroposterior and both lateral view of breast were obtained 5 minutes after iv injection of 740 MBq $^{99m}Tc$-MDP. Breast uptake pattern of $^{99m}Tc$-MDP was analyzed by a grade system: 0=no uptake, grade 1=bilateral diffuse uptake, grade 2=asymmetric faint uptake, grade 3=focal hot uptake. 20 cases were pathologically confirmed by excision biopsy or aspiration biopsy. 14 cases were normal in physical examination and mammogram. Results: Pathologic results showed 7 carcinomas, 6 benign solid tumors, and 7 fibrocystic changes. Grade 3 pattern of $^{99m}Tc$-MDP uptake was noted in 4/7 carcinomas, 3/6 benign solid tumors, and 1/7 fibrocystic changes. Grade 2 pattern was 217, 0/7, 3/7 respectively. The average L/B ratio was 1.66 in carcinomas, 1.68 in benign solid masses, 1.20 in fibrocystic diseases, 1.05 in normal patients. L/B ratio was higher in carcinoma and benign mass groups than in fibrocystic change and normal control groups(p=0.005). But there was no statistical difference between L/B ratio of malignant mass group and benign mass group. Conclusion: $^{99m}Tc$-MDP scan is not suitable to routine clinical use for breast mass diagnosis. It might be used in limited conditions when whole body bone scan is planned.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Analysis on Subjective Image Quality Assessments for 4K-UHD Video Viewing Environments (4K-UHD 비디오 시청환경 특성분석을 위한 주관적 화질평가 분석)

  • Park, In-Kyung;Ha, Kwang-Sung;Kim, Mun-Churl;Cho, Suk-Hee;Cho, Jin-Soo
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.563-581
    • /
    • 2010
  • In this paper, we perform subjective visual quality assessments on UHD video for UHD TV services and analyze the assessment results. Demands for video services have been increased with availabilities of DTV, Internet and personal media equipments. With this trend, the demands for high definition video have also been increasing. Currently, 2K-HD ($1920{\times}1080$) video have been widely consumed over DTV, DVD, digital camcoders, security cameras and other multimedia terminals in various types, and recently digital cinema contents of 4K-UHD($3840{\times}2160$) have been popularly produced and the cameras, beam projects, display panels that support for 4K-UHD video start to come out into multimedia markets. Also it is expected that 4K-UHD service will appear soon in broadcasting and telecommunications environments. Therefore, in this paper, subjective assessments of visual quality on resolutions, color formats, frame rates and compression rates have been carried to provide basis information for standardization of signal specification of UHD video and viewing environments for future UHDTV. As the analysis on the assessments, UHD video exhibits better subjective visual quality than HD by the evaluators. Also, the 4K-UHD test sequences in YUV444 shows better subjective visual quality than the 4K-UHD test sequences in YUV422 and YUV420, but there is little perceptual difference on 4K-UHD test sequences between YUV422 and YUV420 formats. For the comparison between different frame rates, 4K-UHD test sequences of 60fps gives better subjective visual quality than those of 30fps. For bit-depth comparison, HD test sequences in 10-bit depth were little differentiated from those in 8-bit depth in subject visual quality assessment. Lastly, the larger the PSNR values of the reconstructed 4K-UHD test sequences are, the higher the subjective visual quality is. Against the viewing distances, the differences among encoded 4K-UHD test sequences were less distinguished in longer distances from the display.

Marine Environmental Characteristics of Goheung Coastal Waters during Cochlodinium polykrikoides Blooms (Cochlodinium polykrikoides 적조 발생시의 한국 남해안 고흥 연안의 해양환경 특징)

  • Lee, Moon Ock;Kim, Byeong Kuk;Kim, Jong Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.166-178
    • /
    • 2015
  • We investigated marine environmental characteristics of Goheung coastal areas in August where is known to be the first outbreak site of Cochlodinium polykrikoides (hereafter C. polykrikoides) blooms, based on the oceanographic data observed from 1993 to 2013 around the Korean southern coastal waters including Eastern China Sea by National Fisheries Research and Development Institute (NFRDI). The data of NOAA/NGSST satellite images as well as numerical simulation results by Seo et al. [2013] were also used for analysis. Water temperatures at the surface and bottom layers in Goheung coast, i.e. Narodo, were $25.0^{\circ}C$ and $23.7^{\circ}C$ so that they were higher than $23.8^{\circ}C$ and $19.4^{\circ}C$ in Geoje coast where is a reference site, respectively. In addition, salinities at the surface and bottom layers in Goheung coast were 31.78 psu and 31.98 psu so that they were a little higher than 31.54 psu at the surface but a little lower than 32.79 psu at the bottom in Geoje coast, respectively. That is, the differences in water temperature or salinity between the surface and bottom layers in Goheung coast in August were not large compared to Geoje coast. This suggests that stratification in Goheung coast in August is fairly weak or may not be established. In addition, the concentrations of DIN and DIP at the surface layer were 0.068 mg/L ($4.86{\mu}M$) and 0.015 mg/L ($5.14{\mu}M$) in Goheung coast while 0.072 mg/L ($5.14{\mu}M$) and 0.01 mg/L ($0.32{\mu}M$) in Geoje coast, so they did not indicate a meaningful difference. On the other hand, when C. polykrikoides blooms, water temperature and salinity in August at the station 317-22 ($31.5^{\circ}N$, $124^{\circ}E$) of the East China Sea, where is near the mouth of Yangtze River, were $27.8^{\circ}C$ and 31.61 psu, respectively. Thus, water temperature was much higher whereas salinity was almost similar compared to Goheung coast. Furthermore, concentrations of $NO_3-N$ and $PO_4-P$ in the East China Sea in August were remarkably high compared to Goheung coast. When C. polykrikoides blooms, according to not only the image data of satellites NOAA/NGSST but also numerical experiment results by Seo et al.[2013], the freshwater out of Yangtze River was judged to clearly affect the Korean southern coastal waters. Therefore, the supply of nutrients in terms of Yangtze River may greatly contribute to the outbreak of C. polykrikoides blooms in Goheung coast in summer.