• Title/Summary/Keyword: Difference Image

Search Result 3,868, Processing Time 0.031 seconds

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

An Estimation of Concentration of Asian Dust (PM10) Using WRF-SMOKE-CMAQ (MADRID) During Springtime in the Korean Peninsula (WRF-SMOKE-CMAQ(MADRID)을 이용한 한반도 봄철 황사(PM10)의 농도 추정)

  • Moon, Yun-Seob;Lim, Yun-Kyu;Lee, Kang-Yeol
    • Journal of the Korean earth science society
    • /
    • v.32 no.3
    • /
    • pp.276-293
    • /
    • 2011
  • In this study a modeling system consisting of Weather Research and Forecasting (WRF), Sparse Matrix Operator Kernel Emissions (SMOKE), the Community Multiscale Air Quality (CMAQ) model, and the CMAQ-Model of Aerosol Dynamics, Reaction, Ionization, and Dissolution (MADRID) model has been applied to estimate enhancements of $PM_{10}$ during Asian dust events in Korea. In particular, 5 experimental formulas were applied to the WRF-SMOKE-CMAQ (MADRID) model to estimate Asian dust emissions from source locations for major Asian dust events in China and Mongolia: the US Environmental Protection Agency (EPA) model, the Goddard Global Ozone Chemistry Aerosol Radiation and Transport (GOCART) model, and the Dust Entrainment and Deposition (DEAD) model, as well as formulas by Park and In (2003), and Wang et al. (2000). According to the weather map, backward trajectory and satellite image analyses, Asian dust is generated by a strong downwind associated with the upper trough from a stagnation wave due to development of the upper jet stream, and transport of Asian dust to Korea shows up behind a surface front related to the cut-off low (known as comma type cloud) in satellite images. In the WRF-SMOKE-CMAQ modeling to estimate the PM10 concentration, Wang et al.'s experimental formula was depicted well in the temporal and spatial distribution of Asian dusts, and the GOCART model was low in mean bias errors and root mean square errors. Also, in the vertical profile analysis of Asian dusts using Wang et al's experimental formula, strong Asian dust with a concentration of more than $800\;{\mu}g/m^3$ for the period of March 31 to April 1, 2007 was transported under the boundary layer (about 1 km high), and weak Asian dust with a concentration of less than $400\;{\mu}g/m^3$ for the period of 16-17 March 2009 was transported above the boundary layer (about 1-3 km high). Furthermore, the difference between the CMAQ model and the CMAQ-MADRID model for the period of March 31 to April 1, 2007, in terms of PM10 concentration, was seen to be large in the East Asia area: the CMAQ-MADRID model showed the concentration to be about $25\;{\mu}g/m^3$ higher than the CMAQ model. In addition, the $PM_{10}$ concentration removed by the cloud liquid phase mechanism within the CMAQ-MADRID model was shown in the maximum $15\;{\mu}g/m^3$ in the Eastern Asia area.

The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures (하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포)

  • Sung, Chai-Ryun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.375-390
    • /
    • 2009
  • Statement of problem: Implant supported overdenture is accepted widely as a way to restore edentulous ridge providing better retention and support of dentures. Various types of attachment for overdenture have been developed. Purpose: The purpose of this study was to investigate the influence of attachment type in implant overdentures on the biomechanical stress distribution in the surrounding bone, prosthesis and interface between implant and bone. Material and methods: Finite element analysis method was used. Average CT image of mandibular body(Digital $Korea^{(R)}$, KISTI, Korea) was used to produce a mandibular model. Overdentures were placed instead of mandibular teeth and 2mm of mucosa was inserted between the overdenture and mandible. Two implants($USII^{(R)}$, Osstem, Korea) were placed at both cuspid area and 4 types of overdenture were fabricated ; ball and socket, Locator, magnet and bar type. Load was applied on the from second premolar to second molar tooth area. 6 times of finite element analyses were performed according to the direction of the force $90^{\circ}$, $45^{\circ}$, $0^{\circ}$ and unilateral or bilateral force applied. The stress at interface between implants and bone, and prosthesis and the bone around implants ware compared using von Mises stress. The results were explained with color coded graphs based on the equivalent stress to distinguish the force distribution pattern and the site of maximum stress concentration. Results: Unilateral loading showed that connection area between implant fixture and bar generated maximum stress in bar type overdentures. Bar type produced 100 Mpa which means the most among 4 types of attachments. Bilateral loading, however, showed that bar type was more stable than other implants(magnet, ball and socket). 26 Mpa of bar type was about a half of other types on overdenture under $90^{\circ}$ bilateral loading. Conclusions: In any directions of stress, bar type was proved to be the most vulnerable type in both implants and overdentures. Interface stress did not show any significant difference in stress distribution pattern.

Proteomic Assessment of the Relevant Factors Affecting Pork Meat Quality Associated with Longissimus dorsi Muscles in Duroc Pigs

  • Cho, Jin Hyoung;Lee, Ra Ham;Jeon, Young-Joo;Park, Seon-Min;Shin, Jae-Cheon;Kim, Seok-Ho;Jeong, Jin Young;Kang, Hyun-sung;Choi, Nag-Jin;Seo, Kang Seok;Cho, Young Sik;Kim, MinSeok S.;Ko, Sungho;Seo, Jae-Min;Lee, Seung-Youp;Shim, Jung-Hyun;Chae, Jung-Il
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.11
    • /
    • pp.1653-1663
    • /
    • 2016
  • Meat quality is a complex trait influenced by many factors, including genetics, nutrition, feeding environment, animal handling, and their interactions. To elucidate relevant factors affecting pork quality associated with oxidative stress and muscle development, we analyzed protein expression in high quality longissimus dorsi muscles (HQLD) and low quality longissimus dorsi muscles (LQLD) from Duroc pigs by liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based proteomic analysis. Between HQLD (n = 20) and LQLD (n = 20) Duroc pigs, 24 differentially expressed proteins were identified by LC-MS/MS. A total of 10 and 14 proteins were highly expressed in HQLD and LQLD, respectively. The 24 proteins have putative functions in the following seven categories: catalytic activity (31%), ATPase activity (19%), oxidoreductase activity (13%), cytoskeletal protein binding (13%), actin binding (12%), calcium ion binding (6%), and structural constituent of muscle (6%). Silver-stained image analysis revealed significant differential expression of lactate dehydrogenase A (LDHA) between HQLD and LQLD Duroc pigs. LDHA was subjected to in vitro study of myogenesis under oxidative stress conditions and LDH activity assay to verification its role in oxidative stress. No significant difference of mRNA expression level of LDHA was found between normal and oxidative stress condition. However, LDH activity was significantly higher under oxidative stress condition than at normal condition using in vitro model of myogenesis. The highly expressed LDHA was positively correlated with LQLD. Moreover, LDHA activity increased by oxidative stress was reduced by antioxidant resveratrol. This paper emphasizes the importance of differential expression patterns of proteins and their interaction for the development of meat quality traits. Our proteome data provides valuable information on important factors which might aid in the regulation of muscle development and the improvement of meat quality in longissimus dorsi muscles of Duroc pigs under oxidative stress conditions.

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF

A Study of Deconstruction in Clothing -Comparison of Clothing with Architecture- (복식에 나타난 해체주의 양식연구 -건축과 복식의 비교-)

  • 전혜정
    • Journal of the Korean Society of Costume
    • /
    • v.32
    • /
    • pp.293-312
    • /
    • 1997
  • Deconstructionism is a philosophical stream in the latter half of 20'th century which goes against western metaphysics and tries to deconstruct the dualism e.g. eastern/west-ern man/woman. Its main concepts are 'indi-vidual' 'other' 'difference' 'restoration of the repressed' 'decentralization' 'Today it shows strong influences in literature art, and other social fields. This study investigated inner meanings and exterior forms represented in clothing on the base of Jacques Derrida's theory in order to re-search modes of deconstruction in is. And it compared clothing with architecture among other genres of art in order to discover similarities between through and modes of art in a certain period. For illuminating concept of deconstruction I referred to the literatures of preceding studies and for deconstruction's characteristics in both clothing and architec-ture I referred work's collection book $\ulcorner$collec-tions$\lrcorner$ and other related books dealing from 1960's to this point. As a rsult there are four modes of decons-truction in both clothing and architecture as follows; 1) Differenance which is a concept of the dif-ference in time and space as being trace. 2) In termeaning of meanings which is not present in reality but re-interpreted a new in the future. 3) Interxtuality in which a texte is not alone but with others 4) Dis.De phenomenon in which distortion and fragmentation forms occur as the result of the denial of perfection and reson. There are characteristics of modes of de-construction in clothing as follows; 1) Differance; R.Gigli, P. Rabanne. G.Bersace, V.Westwood are representatives of the cloth-ing which is combined with the past the pres-ent and the future or is re-viewed as the clothing of the past in the present point of view. J. Watanabe R. Dawakubo I miyake are representatives of the clothing which is out-date but re-viewed in the sense of recollec-tion and re-usage. 2) Intermeaning of meanings: R. kawakubo I, Miyake Y,Yamamoto are representatives of the clothing which is incomplete but re-interpreted in the future and appears to be new-fashioned according to ways of bnding wearing throwing on and tying J.C. Castel-bajac K.Hamnett S.Sprouse are representa-tives of the clothing which is made up of ab -stract forms scribbling or symbolic letters which appears to be different according to view-point of observers. 3) Intertextuality ;J.P.Gaultier K.Hamnett, Comme des Gar ons are representatives of intertextuality of gender which avoids the 여-ality of man/woman J.P Gaultier G,Versace J. galliano are representatives of the intertex-tuality of time place and occasion which mixes temporality extensity and purposiveness. J.P Gaultier G,Versace are representatives of the intertextuality of coordination which combines items different in image purpose and use. P.Rabanne A,Courr ges R,Gernreic I,Miyake are representatives of the intertextuality of mat-ter which uses heterogeneous matter different from cloth. 4) Dis.De-phenomenon: R, Kawakubo I.Mi-yake J.P.Gaultier are representatives of the de-composition which discloses distortion and exag-geration of form through destructing the estab-lished way of construction J.Galliano R.Kawa-kubo Devota Y Lomba arte representatives of the decentring which restores the repressed and the alienated on the one hane and shows front-centrality on the other. Comme des Gar ones is representative of the discontinuity because of which right and left up and down are not in har-mony with one another. J,Galliano J.P,Gaultier T,Mugler are representatives of the disruption by way of which one makes one's body exposed through intentional slashes or holes. As a consequence deconstructionism enabled us to investigate similarities between through of deconstruction and modes of art interms of diffrance Intermeaning of meanings intertextuality and Dis De-phenomenon. And we found that deconstruction was a phase of development in that it as a all-comprising and multiple concept tries to pursue the new through deconstruction.

  • PDF

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Combination Effect of Various Freezing and Thawing Techniques on Quality and Nutritional Attributes of Onions (다양한 냉·해동 방법에 따른 양파의 이화학적 특성 및 영양성분 변화)

  • Jung, You-Kyoung;Jang, Min-Young;Hwang, In-Guk;Yoo, Seon-Mi;Min, Sang-Gi;Jo, Yeon-Ji;Chun, Ji-Yeon;Choi, Mi-Jung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.10
    • /
    • pp.1492-1503
    • /
    • 2015
  • This study evaluated the combination effect of various freezing and thawing techniques on the quality and nutritional aspects of onions. Onions were frozen by natural air convection freezing (NCF), air blast freezing (ABF), and liquid nitrogen freezing (LNF). Onions were frozen for 76 min by NCF, 9 min by ABF, and 9 min by LNF. The freezing treatment was stopped when the core temperature reached $-12^{\circ}C$ for NCF and ABF, and $-120^{\circ}C$ for LNF. Frozen samples were thawed through natural air convection thawing, running water thawing, sonication thawing (ST), or microwave thawing. The quality and nutritional aspects of frozen-thawed onions were evaluated by measuring thawing loss, pH, texture, water content, color, and SEM image. ST was found to cause the least loss in onion sample among the tested thawing methods, whereas the freezing methods did not cause any significant loss. In our experiment, thawing is found to be a more critical technique when compared to that of freezing. There were no clear quantifications or trends of pH and water content among different freezing and thawing techniques. The highest total color difference (${\Delta}E$) was observed in the NCF sample. For morphological observation, ABF gave the smallest ice crystal size, as well as minimum cell collapse. Loss of vitamin C, free sugar, and organic acid content was lower in the ABF and ST sample, when compared to other trials. In our study, we found that combination of ABF and ST could preserve the quality and nutritional aspects of frozen-thawed onions better than other methods.

Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease (폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성)

  • Park, Hoon-Hee;Roh, Dong-Wook;Kim, Sei-Young;Rae, Dong-Kyeong;Lee, Min-Hye;Kang, Chun-Goo;Lim, Han-Sang;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Purpose: The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomograhpy ($^{18}F-FDG $PET) for the non-invasive differentiation of focal lung lesions originated from cancer or inflammation disease by combined visual image interpretation and semi-quantitative uptake value analysis has been documented. In general, Standardized Uptake Value(SUV) is used to diagnose lung disease. But SUV does not contain dynamic information of lung tissue for the glucose. Therefore, this study was undertaken to hypothesis that analysis of dynamic kinetics of focal lung lesions base on $^{18}F-FDG$ PET may more accurately determine the lung disease. So we compared Time Activity Curve(TAC), Standardized Uptake Value-Dynamic Curve(SUV-DC) graph pattern with Glucose Metabolic Rate(MRGlu) from Patlak analysis. Methods: With lung disease, 17 patients were examined. They were injected with $^{18}F-FDG$ over 30-s into peripheral vein while acquisition of the serial transaxial tomographic images were started. For acquisition protocol, we used twelve 10-s, four 30-s, sixteen 60-s, five 300-s and one 900-s frame for 60 mins. Its images were analyzed by visual interpretation TAC, SUV-DC and a kinetic analysis(Patlak analysis). The latter was based on region of interest(ROIs) which were drawn with the lung disease shape. Each optimized patterns were compared with itself. Results: In TAC patterns, it hard to observe cancer type with inflammation disease in early pool blood area but over the time cancer type slope more remarkably increased than inflammation disease. SUV-DC was similar to TAC pattern. In the result of Patlak analysis, In time activity curve of aorta, even though inflammation disease showed higher blood activity than cancer, at first as time went by, blood activity of inflammation disease became the lowest. However, in time activity curve of tissue, cancer had the highest uptake and inflammation disease was in the middle. Conclusion: Through the examination, TAC and SUV-DC could approached the results that lung cancer type and inflammation disease type has it's own difference shape patterns. Also, it has outstanding differentiation between cancer type and inflammation in Patlak and MRGlu analysis. Through these analysis methods, it will helpful to separation lung disease.

  • PDF