• Title/Summary/Keyword: Difference Analysis of Performance

Search Result 2,495, Processing Time 0.032 seconds

Energy Consumption Characteristics and Evaluation of Thermal Insulation Performance in Accordance with Built Year of Apartment Complex (공동주택의 준공연도에 따른 단열성능 평가 및 에너지소비 특성에 관한 연구)

  • Choi, Doo Sung;Lee, Myung Eun;Chun, Hung Chan
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.79-86
    • /
    • 2014
  • Studies have shown that the thermal performance of buildings changes depending on the year of construction completion. It leads to increased energy consumption of buildings and significant financial burden on users. Thus, this study has calculated the thermal insulation performance of 86 apartments quantitatively, using temperature difference ratio and sensible heat flux. Also, energy consumption characteristics depending on the year of construction completion and thermal insulation performance were analyzed by comparatively analyzing the results of insulation performance evaluation and heating costs. The analysis results are as follows. As for thermal insulation performance, it was around 70% lower in the apartments completed before 1985, compared to apartments completed after 2010. As for heating costs, the apartments with the highest heating cost incurred 1.5 higher heating cost than the apartment with the lowest heating cost. In terms of the insulation performance evaluation, the difference was 2.5-fold.

Effect of information Infrastructure Level on Forwarder's Business Performance (복합운송주선업의 정보인프라 수준과 성과에 관한 연구)

  • Lee, Jung-Sae
    • International Commerce and Information Review
    • /
    • v.1 no.2
    • /
    • pp.167-181
    • /
    • 1999
  • In this research the levels of information infrastructure of selected forwarders were measured and analyzed a relationship with business performance. The selected forwarder was consisted of local forwarder group and foreign invested forwarder group. In this analysis the level of information infrastructure of foreign invested forwarder group was higher than local forwarder group, and accordingly their performance was found a difference. i. e. A positive significant relationship was found between the level of information infrastructure and forwarders' business performance by means of correlation analysis.

  • PDF

The Influences of the Important Perception on Food Hygiene to Kitchen Employee's Performance in Hotel Banquet (호텔 연회 주방 종사원의 식품위생 중요도 인식이 수행도에 미치는 영향)

  • Kim, Ju-Myong;Kim, Auk-Ran;Jun, Heo
    • Culinary science and hospitality research
    • /
    • v.13 no.1 s.32
    • /
    • pp.75-86
    • /
    • 2007
  • This study was carried out to find out the effect of food hygiene awareness on kitchen employees' performance in the banquet cuisine of five-star hotels in Seoul. 279 kitchen employees were asked to fill out the questionnaire, and the collected data were analyzed by SPSS package(version 11.0). First, results of analysis on food hygiene showed that there were four factors, each respectively named as, food security regulations, food storage, period of circulation of food, and food safekeeping. Second, after analyzing each item in whole according to each of the factors, the average degree of priority on food hygiene in general was 4.52. Results according to each of the elements showed that food security regulations(4.56) and period of circulation of food(4.55) were considered as a priority. After analyzing the difference between the degree of priority and degree of performance according to each of the factors, it was found out that the latter was significantly lower than the former in all factors. Third, after analyzing the difference of food hygiene priority in accordance with general characteristics, statistically significant difference was only shown in education(F=3.308, p<0.05) and class(F=4.418, p<0.01). Fourth, after analyzing the difference of food hygiene performance in accordance with general characteristics, the only significant difference was found in food security regulation of education(F=4.418, p<0.01) and food security regulation of class(F=3.859, p<0.01). Fifth, after analyzing the effect of cook's awareness of priority on food hygiene on the degree of performance, it was found out that the awareness of priority on food hygiene had a positive effect(+) on the degree of performance. Therefore, we can conclude that as kitchen employees recognize the priority on the food hygiene better, their degree of performance was higher.

  • PDF

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.

Comparison between CFD analysis and experiments according to various PEMFC flow-field designs (유로 형상 변화에 따른 CFD 해석 결과와 PEM 연료전지 성능 비교)

  • Lee, Kang-In;Park, Min-Soo;Lee, Se-Won;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.572-575
    • /
    • 2008
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in four kinds of flow-field designs without additional measurement equipment, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, the performance values of PEMFC according to the flow-field configurations were measured via a single cell test. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. So, the single serpentine configuration gave the highest performance. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

  • PDF

A Performance Comparison of Positioning Methods Considering Measurement Noise (측정 잡음을 고려한 위치 결정 기법의 성능비교)

  • Park, Chan-Sik;Yim, Jae-Geol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1176-1181
    • /
    • 2010
  • This paper proposes three positioning algorithms using TOA measurements: 1) The well-known linearization method using Taylor series, 2) a modified Savarese method considering measurement noise, which does not need linearization, and 3) a modified Bancroft method where TOA measurements instead of pseudorange measurements are considered. Furthermore, through an error analysis, for Savarese method, divergence of altitude is anticipated if the transmitters are located at the same height. To prevent height divergence, the Savarese method is modified again for receivers which assumed moving on the even plane. Error analysis also shows the relationship between Bancroft and Savarese method. From the analysis it is expected that the performance of Savarese method is worse than Bancroft method because of error amplification during difference operation. Experiments using real TOA measurement from the time difference of ultra sound and RF validate the proposed methods and show that analysis is correct.

Influence of post-pouring joint on long-term performance of steel-concrete composite beam

  • Huang, Dunwen;Wei, Jun;Liu, Xiaochun;Zhang, Shizhuo;Chen, Tao
    • Steel and Composite Structures
    • /
    • v.28 no.1
    • /
    • pp.39-49
    • /
    • 2018
  • The concrete bridge decks are usually precast and in-situ assembled with steel girders with post-pouring joint in the construction practice of super-wide steel-concrete composite beam. But the difference of concrete age between the precast slabs and the post-pouring joint has been not yet considered for the long-term performance analysis of this kind composite beam. A simply supported precast-assembled T-shaped beam was taken as an example to analyze the long-term performance of steel-concrete composite beam with post-pouring joint. Based on the deformation coordination conditions of the old-new concrete deck and steel girder, a theoretical model for the long-term behavior of precast-assembled composite beam is proposed in this paper according to age-adjusted effective modulus method. Then, the feasibility of the proposed model is verified by the available test data from the Gilbert's composite beams. Parametric studies were preformed to evaluate the influences of the cross-sectional area ratio of the post-pouring joint to the whole bridge deck, as well as the difference of concrete age between the precast slabs and the post-pouring joint, on the long-term performance of the composite beam. The results indicate that the traditional method without considering the age difference would seriously underestimate the effect of creep and shrinkage of concrete bridge decks. The concrete age difference between the precast slabs and the post-pouring joint should be demonstrated for the life cycle design and long-term performance analysis of precast-assembled steel-concrete composite beams.

The Importance-Performance Analysis(IPA) of the Tourism Products as a Means of Railway Transportation (교통운송특성을 중심으로 철도운송 관광상품 IPA 분석)

  • Ju, Yong-Jun;Lee, Yong-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.900-907
    • /
    • 2009
  • In this research, railway transportation by means of the characteristics of tourism in the selection of railroad tourism and to clarify the difference in IPA is a primary purpose of this research. In addition, the train travel experience would like to clarify the difference in the importance and performance. This research fellows the indication points. First, by means of transportation to select train tourism product is the difference in the importance and performance in the 25 items. Second, the urgent needs to improve part 'Concentrate Here' side of the train, the temperature of the reasonable air-conditioning, and the appropriate means of transport links to the information service has been identified.'Low Priority' side of the entry tourist train operation of the frequency and interval, a total of 26 items, including the efforts of more than the current level of commitment was expected to be unnecessary. Third, according to the experience of sightseeing train railway transportation as a means to help train tourism product selection was the difference in the importance and performance.

ADSL Network Configuration and Performance Analysis based on Packet Mode (패킷모드에 의한 ADSL 망 구성 및 성능 분석)

  • 오채형;이운영임병학김이한
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.131-134
    • /
    • 1998
  • This paper is describing an ADSL access network configuration by packet mode and analyzed the performance of this ADSL network. We are interesting in difference between ATM mode and packet mode concerning to the performance and service availability. So, this paper has described the characteristics of packet mode ADSL network.

  • PDF

Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm (건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석)

  • Park, Sihun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.