• Title/Summary/Keyword: Diastole

Search Result 55, Processing Time 0.02 seconds

The Echocardiographic Assessment and clinical Application of Cardiac Disease in Korean Jin-do dog (진돗개에서 심장초음파 측정치의 평가와 임상적 응용 I. 심장초음파 측정치)

  • 박인철;강병규;손창호
    • Journal of Veterinary Clinics
    • /
    • v.17 no.1
    • /
    • pp.178-186
    • /
    • 2000
  • Echocardiography was performed on 29 normal Korea Jin-do dogs(21 adults and 8 prematures) and the images were taken from chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view, respectively. The following cardiac parameters, in systole and diastole, were measured on the echoocardographic images: aortic dimension(AO), left atrial dimension(LA), left ventricular internal dimention at end-diastole (LVIDd), left ventricular internal dimention at end-systole(LVIDs), interventricular septal wall thickness at end-diastole(IVSd), interventricular septal wall thickness at end-systole(IVSs), left ventricular wall at end-diastole(LVWd), left ventricular wall at end-systole(LVWs). The cardiac parameters were not significantly different between sex and among imaging planes. The size of cardiac parameters increaed as regression lines according to body weights. These results suggest that the chordae tendineae level short-axis view, left ventricular outflow tract long-axis view and 4-chamber long-axis view can be utilized for the left cardiac examination, and these cardiac parameters can be used to basic dat for diagnosing the cardiac diseases in Korea Jin-do dog.

  • PDF

Numerical Studies of Flow Across End-to-Side Distal Vascular Bypass Graft Anastomoses

  • Kim, Y.H.;Kim, J.H.;Shin, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.339-352
    • /
    • 1992
  • A numerical simulation of the steady and pulsatile flow across the end-to-side anastomosis was performed In order to understand the role of flow dynamics in the preferential bevel opment of distal anastomotic intimal hyperplasla. The finite element technique was employed to solve two-dimensional unsteady pulsatile flow in that region. The results of the steady flow revealed that low shear stresses occur at the proximally occluded host artery and at the recirculation region in the Inner wall just distal to the toe region of the anastomosis. The nor- mal;zed wall shear rate was increased, as was the recirculation zone size in the host artery of the by-pass graft anastomosis, with increased anastomotic junction angle. In order to min imize the size of the low wall shear region which might result in the intimal hyperplasia in the by-pass graft anastomosis, a smaller anastomotic junction angle is recommended. The pulsatile flow simulation revealed flow that regions of low and ascillating mali shear do exist near the anastomosis as In the steady simulation. The shift of stagnation point depends on the pulsation of the flow. As the flow was accelerated at systole, the stagnation point moved downstream, disappered at early diastole and reappeared during late diastole. Low shear stress was also found along both walls of the occluded proximal artery. However, the diastolic flow behavior is quite different from the steady results. The vortex near the occluded artery moved downstream and inwardly during late systole, and disappeared during diastole. Recirculations proximal to the toe and heel regions were significant during diastole. Shear stress oscillation was found along the opposite wall. The results of the present study revealed that tow shear occurs at the proximally occluded host artery aud the recirculation region in the inner wall Just dlstal to the toe region of the anastomosis. The present study suggested that the regions of fluctuated wall shear stress wit flow separation is correlated with the preferential developing regions of anastomosis neointial fibrous hyperplasia.

  • PDF

Method of Deciding Elastic Modulus of Left and Right Ventricle Reconstructed by Echocardiography Using Finite Element Method and Stress Analysis

  • Han, Geun-Jo;Kim, Sang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.2
    • /
    • pp.217-224
    • /
    • 1994
  • In order to study the shape and dimensions of heart, a procedure to reconstruct a three dimensional left ventricular geometry from two dimensional echocardiographic images was studied including the coordinate transformation, curve fitting and interpolation utilizing three dimensional position registration arm. Nonlinear material property of the left ventricular myocardium was obtained by finite element method performed on the reconstructed geometry and by optimization techniques which compared the computer predicted 3D deformation with the experimentally determined deformation. Elastic modulus ranged from 3.5g/$cm^2$ at early diastole to l53g/$cm^2$ at around end diastole showing slightly nonlinear relationship between the modulus and the pressure. Afterwards using the obtained nonlinear material propertry the stress distribution related with oxyzen consumption rate was analyzed. The maximum and minimum of ${\sigma}_1$ (max. principal stress) occurred at nodes on the second level intersection points of x-axis with endocardium and with epicardium, respectively. And the tendency of the interventricular septum to be flattened was observed from the compressive ${\sigma}_1$ on the anterior, posterior nodes of left ventricle and from the most significant change of dimension in $D_{RL}$ (septal-lateral dimension of right ventricle).

  • PDF

Control of Left Ventricular Assist Device Using Neural Network Feedforward Controller (인공신경망 Feedforward 제어기를 이용한 좌심실 보조장치의 제어실험)

  • 정성택;김훈모;김상현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.4
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper, we present neural network for control of Left Ventricular Assist Device(LVAD) system with a pneumatically driven mock circulation system. Beat rate(BR), Systole-Diastole Rate(SDR) and flow rate are collected as the main variables of the LVAD system. System modeling is completed using the neural network with input variables(BR, SBR, their derivatives, actual flow) and output variable(actual flow). It is necessary to apply high perfomance control techniques, since the LVAD system represent nonlinear and time-varing characteristics. Fortunately. the neural network can be applied to control of a nonlinear dynamic system by learning capability In this study, we identify the LVAD system with neural network and control the LVAD system by PID controller and neural network feedforward controller. The ability and effectiveness of controlling the LVAD system using the proposed algorithm will be demonstrated by experiment.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.44-44
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was performed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were peformed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.

  • PDF

Contrast-Enhanced Magnetic Resonance Imaging at True End-Diastole to Quantify Reproducible Transmural Extent of Myocardial Hyperenhancement

  • 최병욱;최규옥;김영진;정남식;임세중
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.91-91
    • /
    • 2003
  • To determine feasibility of contrast-enhanced MRI (co-MRI) at true end-diastole (ED) free from limitation of time for inversion-recovery and trigger window for quantifying transmural extent of infarction. 대상 및 방법: MRI was peformed in 18 patients with myocardial infarction. Cine imaging and co-MRI with same registered slices in short axis were performed. To allow true ED co-MRI, ECG synchronization should use two RR-intervals for one acquisition of a segment of k-space by setting the heart rate to half that of the true heart rate. Trigger delay time was adjusted to the RR-interval for imaging at ED and to the sum of RR-interval plus the time between R-wave and the end-systole (ES) determined in cine images for imaging at ES.

  • PDF

The Effect of an Information using Computer Orogram on the Reduction of Anxiety in Coron Angiogram Subjects (컴퓨터를 이용한 정보제공이 관상동맥조영술 대상자의 검사 전 불안감소에 미치는 영향)

  • Jeong, Kyung-In;Choi, Soon-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.9 no.1
    • /
    • pp.115-125
    • /
    • 2003
  • This study was conducted to investigate whether a computer information offered in advance of the test would decrease anxiety degree in coronary angiogram subjects. The study design was a nonequivalent control group, none-synchronized design. The subjects of study were 53 patients who were admitted at C hospital in K city for coronary angiogram. The 53 subjects were assigned to experimental(25) and control(28) groups. The computer information set up by researcher was used as the experimental treatment and 10 minutes long. Spielberger's state anxiety scale translated by Kim and Shin(1978) and sphygmomanometer were used for data collection. The data were collected from July 1, 2000 to March 31, 2001, and analyzed by chi-square, paried t-test, t-test, ANCOVA, and Pearson's Correlation Coefficients using SPSS/PC+. The results of this study were summarized as follows : 1. The first hypothesis that 'post-test state anxiety score will be lower than pre-test state anxiety score in experimental group' was supported(t=2.40, p=.020). 2. The second hypothesis that 'post-test systole will be lower than pre-test systole in experimental group' was not supported(t=-.30, p=.765). 3. The third hypothesis that 'post-test Diastole will be lower than pre-test diastole in experimental group' was not supported'(t=-1.42, p=.161). 4. The fifth hypothesis that 'the experimental group who is given the computer information will be lower in state anxiety score than the control group who is not given the computer information' was supported(F=9.17, p=.004). 5. The sixth hypothesis that 'the experimental group who is given the computer information will be lower in systole than the control group who is not given the computer information' was supported (F=7.16, p=.010). 6. The seventh hypothesis that 'the experimental group who is given the computer information will be lower in diastole than the control group who is not given the computer information' was not supported'(F=.55, p=.462). 7. The eleventh hypothesis that 'the lower the post-test state anxiety, the lower the uneasiness score during the test' was not supported(r=-.013, p=.926). 8. The eighth hypothesis that 'the lower the post-test state anxiety, the lower the nervousness score during the test' was supported(r=.326, p=.017).

  • PDF

인조신경망을 이용한 좌심실보조장치의 동적 모델링

  • 김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.346-350
    • /
    • 1996
  • This paper presents a Neural Network Identification (NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulation system of Left Ventricular Assist Device(LVD). This system consists of electronic circuits and pneumatic driving circuits. The initation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded. System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, Heart Rate(HR), Systole-Diastole Rate(SDR), which can vary state of system, and preload, afterload, which indicate the systemic dynamic characteristics and output parameters are preload, afterload.

  • PDF

Study for Correlation of 3D-MAC and DSOM with ABR-2000 (피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구)

  • Song, Jung-Oh;Kim, Min-Ae;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.1
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

Ultrasonographic Evaluation of the Thorax and Abdomen in Horse (말에서 흉복부의 초음파상)

  • 김명철;변홍섭;신상태;김용준;이경광;한용만
    • Journal of Veterinary Clinics
    • /
    • v.15 no.1
    • /
    • pp.14-21
    • /
    • 1998
  • Ultrasonogram for kidney, spleens liver, intestine and heart was evaluated 11 Chriu horses and 14 Thoroughbred horse. The kidney was determined at both flan and both 17th intercostal spaces. The spleen was determined at the left 13-17 intercom spacer and the liver was determined at the right 7-13 intercostal space. The heart was determined at the right 4-6 intercostal space and left 3-6 intercostal space. The length, of rig kidney at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 16.2, 12.6, 13.1 and 11.2 mm, respectively. The width of right kidney at the Thoroughbed horse, Thorughbred foul, Cheju horse and Cheju foul were 5.4, 4.3, 4.6 and 4.2 mm, respectively. The depth of right kidney at the Thoroughbred horsed Thoroughbred foul, Cheju horse and Chrju foul were 5.2, 4.4, 4.5 and 4.3 mm, respectively. Similar ultrasonographic measurements were obtained for the left kidney, The left ventricular end-diastolic diameter at the Thoroughbred horse, Thoroughbred fouls Cheju horst and Cheju foul were 107, 83, 85 and 73 mm, respectively. The left ventricular end-systolic diameter were at the Thoroughbred horse, Thoroughbred foul, Cheiu horse and Cheiu foul were 63, 52, 53 and 45 mm, respectively. Also, the interventricular septum in end-diastole, interventricular septum in end-systoles left ventricular wall end-diastoles left ventricular wall end-systoles right ventricular end-diastole diameter, aorta and left atrium at t Thoroughbred horse, Thoroughbred foul, Chriu horse and Chriu foul were measured. Experimental renal stone and enterolith of colon were observed by ultrasonography.

  • PDF