• 제목/요약/키워드: Diaphragm thickness

검색결과 114건 처리시간 0.027초

호흡훈련이 뇌졸중 환자의 횡격막 비대칭에 미치는 영향 (The Effects of Breathing Retraining on Asymmetry of Diaphragm Thickness in Stroke Patients)

  • 김난수;정주현
    • 대한물리의학회지
    • /
    • 제8권2호
    • /
    • pp.263-269
    • /
    • 2013
  • PURPOSE: The purpose of this study was to examine the effects of breathing retraining on asymmetry of diaphragm thickness in stroke patients. METHODS: This study was nonequivalent control group pre-post test design. Subjects were assigned to two different groups(intervention group=10, control group=12). Intervention group conducted breathing retraining program for six-week. Diaphragm thickness was assessed by ultrasound in B-mode with a 7.5 MHz linea probe. The collected data analyzed by Wilcoxon signed rank test and Mann-Whitney U test. RESULTS: The intervention group significantly increased diaphragm thickness ratio on paretic side but the control group showed no significant difference in diaphragm thickness ratio. The control group significantly increased asymmetry of diaphragm thickness, but intervention group showed no significant difference in asymmetry of diaphragm thickness. CONCLUSION: This study showed that breathing retraining increased diaphragm thickness ratio in stroke patients and prevent the increase of asymmetry in diaphragm thickness with stroke patients.

Ultrasonographic findings of the normal diaphragm: thickness and contractility

  • Seok, Jung Im;Kim, Shin Yeop;Walker, Francis O.;Kwak, Sang Gyu;Kwon, Doo Hyuk
    • Annals of Clinical Neurophysiology
    • /
    • 제19권2호
    • /
    • pp.131-135
    • /
    • 2017
  • Background: Neuromuscular ultrasound can be used to assess the diaphragm. Before it can be used clinically, the reference ranges of diaphragm thickness and contractility must be determined. Methods: We measured the thickness of the diaphragm and the diaphragmatic thickening fraction (DTF) in 80 healthy volunteers with ultrasound and collected their demographic information to determine if age, sex, and body mass index (BMI) influence these measures. Results: The thickness of the diaphragm at resting end expiration was $0.193{\pm}0.044cm$ on the right side and $0.187{\pm}0.039cm$ on the left. The DTF was $104.8{\pm}50.6%$ on the right side and $114.9{\pm}49.2%$ on the left. Sex, weight, height, and BMI significantly affected the thickness of the diaphragm, but had little effect on the DTF. Conclusions: Normal reference values for the diaphragm should be helpful when evaluating the diaphragm. The DTF appears more useful than resting diaphragm thickness because it is affected less by individual variation.

다이아프램 두께 변화에 따른 하이브리드 로켓의 후퇴율 향상에 관한 연구 (Effect of Diaphragm Thickness on Regression Rate Improvement in Hybrid Rocket Motor)

  • 류성훈;오지성;문근환;김학철;문희장;김진곤
    • 한국항공운항학회지
    • /
    • 제23권4호
    • /
    • pp.1-5
    • /
    • 2015
  • In this work, a study was conducted to investigate the effect of diaphragm thickness on the regression rate of the hybrid rocket motor. To observe the flow pattern and the recirculation zone, visualizations of combustion chambers with different diaphragm thickness (5mm, 10mm) were performed. It was found that the case with 5 mm thickness had a larger recirculation zone and therefore, had a higher regression rate than the case with 10mm thickness due to the increased residence time and heat transfer toward the fuel surface. Finally, it was concluded that the thickness of diaphragm can be a critical parameter for the enhancement of the regression rate.

뇌졸중 환자의 보행능력에 따른 횡격막 두께와 폐기능 분석 (The Analysis on Diaphragm Thickness and Lung Function of Stroke Patients by Walking Ability)

  • 정주현;김난수
    • 대한물리의학회지
    • /
    • 제6권4호
    • /
    • pp.437-445
    • /
    • 2011
  • Purpose : The purpose of this study was to analysis on diaphragm thickness and lung function of stroke patients by walking ability. Methods : We recruited thirty-five adults after stroke(20 male, 15 female) for our study. The subjects were divided into two groups; independent walking group(11 male, 9 female) and non-independent walking group(9 male, 6 female). Assessment of diaphragm thickness was performed using ultrasound in B-mode with a 7.5 MHz linea probe. During the experiment, the subject was seated in the chair. All subjects performed maximal expiratory flow maneuvers using a spirometer in order to determine the forced expiratory volume in 1 second ($FEV_1$), forced vital capacity(FVC), peak expiratory flow(PEF) and $FEV_1$/FVC. Chest expansion was measured with a tape-measure placed circumferentially around the chest wall at the xiphoid process. The collected data analyzed by independent t-test. Results : The diaphragm thickness were significant differences between the independent walking and nonindependent walking group. Values of forced vital capacity, forced expiratory volume at one second, peak expiratory flow in pulmonary function tests were significant differences between the independent walking and non-independent walking group. However, chest expansion were not significant differences in both of the group. Conclusion : This study showed that walking ability of stroke patients have influenced on diaphragm thickness and pulmonary function.

마이크로 스피커 다이어프램의 진동해석 (Vibration Analysis of Micro Speaker Diaphragm)

  • 홍도관;우병철;안찬우;한근조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.551-554
    • /
    • 2005
  • This study uses a characteristic function to explain correlations between the objective function and design variables. Analysis of means and table of orthogonal array were carried out. The change of shape of diaphragm, thickness of diaphragm and voice coil weight based on the table of orthogonal array is made. Therefore this study carried to decide shape of diaphragm, voice coil weight and thickness of diaphragm for minimizing 1st natural frequency and maximizing 2nd natural frequency of diaphragm using design of experiments and characteristic function with constraints. we showed improved design factors that minimized 1st natural frequency and maximized 2nd natural frequency of diaphragm.

  • PDF

Comparison of Pulmonary Function, Respiratory Muscle Strength, and Diaphragm Thickness between Underweight and Normal Adults

  • Ho-Jeong Shin;Ho-Hee Son
    • 대한물리의학회지
    • /
    • 제18권3호
    • /
    • pp.31-37
    • /
    • 2023
  • PURPOSE: This study aimed to investigate the relationship between being underweight and respiratory function indicators such as pulmonary function, respiratory muscle strength, and diaphragm thickness in normal adults without lung disease. METHODS: The participants in this experiment were thirty young adults. To compare the respiratory function between the underweight and normal weight individuals, 15 participants were selected from each of the underweight and normal weight groups based on body mass index. Respiratory function tests were conducted through pulmonary function tests and respiratory muscle strength tests. Diaphragm thickness was measure with ultrasonography, and physical characteristics were obtained from grip strength and waist circumference. An independent t-test was used to compare the averages of the parameters measured in the two groups. RESULTS: In the respiratory function tests between the two groups, statistically significant differences (p < .05) emerged in the ratio of the predicted forced vital capacity (%FVC), the ratio of the predicted forced expiratory volume in one second (%FEV1), maximal expiratory pressure (MEP), and diaphragm thickness at the functional residual capacity (FRC). There was no statistically significant difference in the forced vital capacity, forced expiratory volume in one second, maximal inspiratory pressure, diaphragm thickness at the total lung capacity, and thickening ratio (p > .05). CONCLUSION: Decreases in some variables of respiratory function, such as the %FVC, %FEV1, MEP, and diaphragm thickness at the FRC were observed in underweight subjects. However, it is difficult to determine whether it affected the overall respiratory function. Future studies are needed to clearly identify the relationship between being underweight and respiratory function.

열공압형 마이크로펌프의 액추에이터 박막 거동 특성에 관한 실험적 연구 (Experimental Study of the Behavior Characteristics of Actuator Diaphragms in Thermopneumatic Micropumps)

  • 이종문;김영득;김우승
    • 대한기계학회논문집B
    • /
    • 제34권6호
    • /
    • pp.599-606
    • /
    • 2010
  • 본 연구에서는 다양한 작동조건(인가전압, 주파수)에 대하여 박막의 두께와 챔버의 직경이 열공압형 마이크로펌프의 액추에이터 박막의 거동 특성에 미치는 영향을 실험적으로 파악하기 위해 다양한 박막 두께와 챔버직경의 액추에이터를 제작하였다. 액추에이터는 파이렉스 표면에 위치한 마이크로히터, 챔버, 그리고 박막으로 구성된다. 모든 인가전압에 대하여 주파수가 10 Hz 이하로 감소함에 따라 박막 중앙의 최대 변위는 박막의 두께와 챔버의 직경에 관계없이 크게 증가한다. 낮은 주파수 영역에서 챔버로 공급되는 열량이 증가함에 따라 박막 중앙의 변위는 박막의 두께가 얇을수록, 챔버의 직경이 작을수록 증가한다. 10 Hz 이상의 주파수 영역에서 박막 두께, 챔버 직경, 공급 열량과 같은 모든 설계 변수가 박막 중앙의 변위에 미치는 영향은 미미하다.

마이크로스피커에서 공명진동수와 QTS 사이의 연관성 (Relationship Between the Resonance Frequency and QTS for Microspeaker)

  • 오세진
    • 한국재료학회지
    • /
    • 제21권7호
    • /
    • pp.403-409
    • /
    • 2011
  • Micro speakers are used to reproduce sound in small electric and information and communications devices, such as cellular phones, PMPs, and MP3 players. The acoustical properties and sound quality, which are changed due to the decreased size of the speaker, are often adjusted varying the type and thickness of the diaphragm. The most widely used diaphragm material is thin polymer. It was previously reported by the author of this paper that the resonance frequency of a micro speaker is changed by the type and thickness of a polymer diaphragm. In this paper, the frequency response near the resonance frequency of a micro speaker was studied as functions of the type and thickness of the polymer diaphragm. While $R_{max}$ and $R_{DC}$ were affected by the type and thickness, an analysis of the electrical impedance curve revealed that $R_o(= R_{max}/R_{DC})$ and ${\Delta}f$ were not changed. Thus, $Q_{TS}$ which was function of $R_o$, ${\Delta}f$, and the resonance frequency, is only related to the resonance frequency. The increase of the resonance frequency led to a proportional rise of $Q_{TS}$. The change of the frequency response near the resonance frequency was not dependent on the type or thickness of the polymer diaphragm, but was affected by the resonance frequency.

An evaluation equation of load capacities for CFT square column-to-beam connections with combined diaphragm

  • Choi, Sung-Mo;Jung, Do-Sub;Kim, Dae-Joong;Kim, Jin-Ho
    • Steel and Composite Structures
    • /
    • 제7권4호
    • /
    • pp.303-320
    • /
    • 2007
  • The objective of this study is to clarify the structural features of members consisting of connection, as a series of the previous study on the CFT column-to-beam tensile connection with combined cross diaphragm. This connection has the merits that the stress is distributed evenly on the beam flange and the diaphragm and the stress concentration is reduced, by improving the stress transfer route and restraining abrupt deformation of diaphragm. The finite element analysis was performed to find out the stress transfer through sleeve which is an important member of the connection with combined cross diaphragm. The length and thickness of sleeve were used as variables for the analysis. As the analysis results, the length and thickness of sleeve didn't influence on the capacity of the connection and played a role of a medium to transfer the stress from the diaphragm to the filled concrete. It is proposed that the appropriate length of sleeve be the same value as the diameter of sleeve and the appropriate ratio of sleeve diameter to sleeve thickness be 20. Two equations for evaluation of the load-carrying capacity of the connection were also proposed through the modification of the evaluation equation suggested in the previous study.

Fabrication of Circular Diaphragm for Piezoelectric Acoustic Devices

  • Lee, Woon-Seob;Kim, Yong-Chul;Lee, Jin-Seung;Lee, Seok-Woo;Lee, Seung-S.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권1호
    • /
    • pp.52-57
    • /
    • 2005
  • This paper describes a fabrication method of a circular diaphragm using boron etching stop method. It will be applied to acoustic transducers such as microphones or microspeakers and so on. The sensitivity is expected to be increased with the circular diaphragm through the simulation results to compare with a general rectangular diaphragm. The borondoped layer which is doped with solid source is sufficient for achieving an etching stop in 20 wt% TMAH, and the thickness is about $7.4{\mu}m$. The diameter of the circular silicon nitride diaphragm was measured to be 2 mm with $1{\mu}m$ thickness. The fabrication of piezoelectric acoustic devices was completed.