• Title/Summary/Keyword: Diaphragm material

Search Result 98, Processing Time 0.022 seconds

Differentiation between Morgagni Hernia and Pleuropericardial Fat with Using CT Findings (CT 소견을 이용한 Morgagni 탈장과 심막주위지방의 감별)

  • Kim Sung-Jin;Cho Beum-Sang;Lee Seung-Young;Bae Il-Hun;Han Ki-Seok;Lee Ki-Man;Hong Jong-Myeon
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.573-578
    • /
    • 2006
  • Background: Generally hernia is diagnosed with simple chest or gastrointestinal x-ray. Sometimes CT or MRI can give lots of information for the diagnosis. However, there was no study for the differentiation with using CT findings between Morgagni hernia and pleuropericardial fat. The aim of this study was to evaluate the useful CT findings for differentiating Morgagni hernia from pleuropericardial fat. Material and Method: We retrospectively analyzed CT scans of eight patients with Morgagni hernia and 20 patients with abundant pleuropericardial fat without peridiaphragmatic lesions. All CT scans were performed with coverage of the whole diaphragm in the inspiration state. We evaluated 1) the presence of the defect of the anterior diaphragm, 2) the interface between the lung and fat, 3) the angle between the chest wall and fat, 4) the continuity between the extrapleural fat and fat, 5) the presence of the vessels within fat, and 6) the presence of a thin line surrounding fat. Result: In all cases with Morgagni hernia, the defect of the anterior diaphragm was seen. The interface was well-defined, smooth, and convex to the lung. The angle with the chest wall was acute. The continuity with the extrapleural fat was not seen. In the cases with abundant pleuropericardial fat, the defect of the anterior diaphragm was seen in three (15%). The interface was usually irregular (n=10) and flat (n=17). The angle with the chest wall was variable. The continuity with the extrapleural fat, that was markedly increased in amount, was usually seen (n=16). The thin line surrounding fat was seen in four cases with Morgagni hernia, however, not seen in all cases with pleuropericardial fat. All of the above findings were statistically significant, however, vessels within fat was not significant to differentiate Morgagni hernia (n=8/8) from pleuropericardial fat (n=14/20). Conclusion: The useful CT findings of Morgagni hernia were fatty mass with sharp margin, convexity toward lung, acute angle with chest wall, and thin line surrounding hernia. Branching structure within fatty mass representing omental vessels that has been known as a characteristic finding of Morgagni hernia was not useful for differentiating Morgagni hernia from pleuropericardial fat.

An Experimental study on the properties and the concrete packing ability of Super Flowing concrete for adapt tp CFT (CFT에 적용하기 위한 고유동화 콘크리트의 물성 및 충전성에 관한 실험적 연구)

  • 강동현;강용학;박희곤;김종구;정근호;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.757-762
    • /
    • 2001
  • CFT concrete has high flowing, high strength and resistance to material separation to use skyscraper structure. It is considered that concrete could fill the lower part of Diaphragm up. This kinds of CFT concrete hardly apply to building below 20 stories. Using the common use strength concrete to building below 20 stories brings to reduce construction cost. This concrete is needed that valid fluidity and packing ability with unit cement content as common use strength concrete. Offering a fundamental data and proportioning in CFT concrete of below 20 stories, it is executed basic property test, analysis of proportioning and mock up test.

  • PDF

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong;Kwon Boo-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.329-334
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performances of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after about six-year-use of the regulators.

Applications of Polycrystalline Silicon Layer to Sensors (다결정실리콘 박막의 센서에의 응용)

  • Park, Sung-June;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1226-1228
    • /
    • 1994
  • Applications of poly-Si layers which are important as sensing and structural material of various sensors were reviewed in this research. A piezoresistive pressure sensor with piezoresistors has sensitivity of $6.93{\mu}$ V/(VmmHg) within 300mmHg. Temperature sensor was studied with measurement range of $-40{\sim}140^{\circ}C$ and $400{\sim}800^{\circ}C$ using boron-doped and undoped poly-Si resistors, respectively. Poly-Si layer was used to transduce volume change of polyimide to stress of silicon diaphragm for humidity sensor.

  • PDF

A Study on Pylon Cable Anchor System in Cable-Stayed Railway Bridge (철도용 사장교의 주탑 케이블 정착부에 관한 연구)

  • Han, Sung-Gwan;Gong, Byung-Seung
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.565-580
    • /
    • 2006
  • Set in constant increase and period current of lively technical development of railroad use and construction of cable stayed bridge railway bridge, one of bridge form of most suitable that think side police officer and the material enemy of bridge that use long rail, is increasing laying stress on the foreign countries. Main tower fixing department of this cable stayed bridge is consisted of main tower flange that support bearing plate, bay ring plate bearing plate, support end rib and diaphragm etc, as stress transmission mechanic that tensility of cable socket into normal force of main tower, and is used this time. These structural elements is very complex the structure and direction of load delivered from socket specially calbe particularly be different, and need FEM analysis that use Thick Shell element for suitable arrangement of mutual stress flowing grasping and absence that follow hereupon because all of the each support plate angle that suport this differ.

  • PDF

A Study on Thermal Degradation of Acrylonitrile Butadiene Rubber (Acrylonitrile Butadiene Rubber의 열적 열화 특성)

  • Kim, Ki-Yup;Kang, Hyun-Koo;Lee, Chung;Ryu, Boo-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.57-63
    • /
    • 2003
  • Thermal degradation of Acrylonitrile butadiene rubber(NBR), which is used for O-ring material as elastomeric sealed diaphragm value in the nuclear power plants, is examined. The thermal degradation is accelerated at 130$^{\circ}C$ by Arrhenius exploit method using the activation energy calculated by thermogravimetric analysis. The weight loss temperature and glass transition temperature are verified for thermally aged NBR. The relationship between dynamic mechanical properties and elongation at break are also investigated. The threshold alue of thermally aged NBR is a ten year in the change of elongation at break.

Piezoelectric Microspeakers Fabricated with High Quality AlN Thin Film (고품질 AlN 박막으로 제작한 압전 마이크로스피커)

  • Yi, Seung-Hwan;Jung, Kyung-Sick;Kim, Dong-Kee;Shin, Gwang-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1455-1460
    • /
    • 2007
  • This paper reports the piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film deposited onto Mo/Ti electrode. This successful achievement, compared to the previous results, is followed by manipulating two material properties: the one is to use a compressively stressed silicon nitride film as a supporting diaphragm (even tensile stressed, around +20 MPa) and the another is to use high quality AlN thin film with compressive residual stress (less than -100 MPa). With these materials, the Sound Pressure Level (SPL) of the fabricated micro speakers shows more than 60 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with 20 Vpeak-to-peak sinusoidal input and with 10 mm distances from the fabricated micro speakers to the reference microphone (B&K Type 2669 & 4192L).

Microstructure and properties of 316L stainless steel foils for pressure sensor of pressurized water reactor

  • He, Qubo;Pan, Fusheng;Wang, Dongzhe;Liu, Haiding;Guo, Fei;Wang, Zhongwei;Ma, Yanlong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.172-177
    • /
    • 2021
  • The microstructure and texture of three 316L foils of 25 ㎛ thickness, which were subjected to different manufacturing process, were systematically characterized using advance analytical techniques. Then, the electrochemical property of the 316L foils in simulated pressurized water reactor (PWR) solution was analyzed using potentiodynamic polarization. The results showed that final rolling strain and annealing temperature had evident effect on grain size, fraction of recrystallization, grain boundary type and texture distribution. It was suggested that large final rolling strain could transfer Brass texture to Copper texture; low annealing temperature could limit the formation of preferable orientations in the rolling process to reduce anisotropy. Potentiodynamic polarization test showed that all samples exhibited good corrosion performance in the simulated primary PWR solution.

Effect of Omentum, Pleura, Diaphragm on Tracheal Autograft Survival (자가이식기관의 생존에 필요한 장막, 흉막, 횡격막의 역할 분석)

  • Keum, Dong-Yoon
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.461-467
    • /
    • 2005
  • Pleura, diaphragm, pericardial fat pad, intercostal muscles and omentum can be used to protect and revascularize the bronchial suture line of tracheal transplantation, lung transplantation and pulmonary resection. The purpose of the present study is to compare the influence of the pleura, diaphragm and omentum in survival of isolated tracheal segments in the experimental animals. Material and Method: Sprague-Dawley rats weighing 250- 350g were used. The animals were divided in three groups; the pleura, omentum and diaphragm. Following intraperitoneal anesthesia, endotracheal intubation was performed. Then the trachea was exposed. A three-ring sec- tion of cervical trachea was excised. The resected trachea was implanted at each sites. After 2 weeks, rats were sacrificed. Histopathological examination of the tracheal segments was performed. For comparison of each groups, histopathological viability of resected tracheal segment was scored by three tissue layers; epithelium, submucosa, and cartilage. The results were presented as average score. Result: In histopathological examination, submucosa and cartilage using tracheal segment necrosis scoring system. The pleural group showed well preserved tissue. There was minimal necrosis and inflammation compared with other groups. In the pleural group, tracheal necrosis scores were $2.17\pm0.983$at epithelium, $1.67\pm0.516$ at submucosa and $2.17\pm0.753$ at cartilage. At the omental group, scores were $1.00\pm0.00,\;1.60\pm0.548\;and\;1.80\m0.447$. In the diaphragmatic group, scores were $1.40:\pm0.894,\;2.40\pm0.547\;and\;2.20\pm0.447$. Total necrosis score were $6.00\pm1.789$ in the pleural group, $4.40\pm0.894$ in the omental group and $6.00\pm1.414$ in the diaphragmatic group. Conclusion: There were no significant viability differences in terms of total necrosis score for the viability of resected tracheal segment. But the best result was achieved in the omental group. Therefore, omental wrapping on tracheal graft site will be beneficial for the prevention of graft necrosis.

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use (가정용 LP가스 저압조정기의 성능 및 수명 평가)

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.23-27
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performance of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after six-year-use of the regulator.