• Title/Summary/Keyword: Diameter Ratio

Search Result 3,121, Processing Time 0.029 seconds

Clinical Analysis of Infantile Hypertrophic Pyloric Stenosis (영아 비후성 유문 협착증의 임상적 분석)

  • Huh, Young-Soo;Lim, Myeung-Kook;Kim, Kyu-Rak
    • Advances in pediatric surgery
    • /
    • v.4 no.1
    • /
    • pp.39-47
    • /
    • 1998
  • Infantile hypertrophic pyloric stensosis(IHPS) occurs in three of 1000 live births, and is a major cause of nonbilious vomiting of early infancy. It's etiology and pathogenesis however are still obscure. The operation of pyloromyotomy described by Ramstedt in 1912 remains the standard treatment. From January 1990 to July 1997, 64 infants with IHPS were treated at the Department of Pediatric Sursery, Yeungnam University Hospital. The ratio of male to female was 7:1, and the most prevalent age ranged from 2 weeks to 8 weeks(81.2 %) of age. Fifty-seven infants were first born (57.8 percent). The body weight of all patients at admission was below the 50 percentile. Age of onset of symptoms was between 2 and 4weeks of age in 23 cases(35.9 %). All infants had a history of nonbilious vomting, generally projectile in nature. Hypokalemia was noted in 14 cases(21.9 %) and hypochloremia in 26 cases(40.6 %). In the preoperative ultrasonography, the average muscle thickness, diameter, and length of the pylorus were 6.3 mm, 12.3 mm, and 17.8 mm. A total of 13 associated anomalies were noted in 12 patients. All cases were treated with Fredet-Ramstedt pyloromyotomy. Postoperative wound infection occured in 3 cases. Thirteen cases(20.3 %) presented intermittent nonprojectile vomiting after operation. With control of oral intake vomiting subsided within one week in 63 patients, and in thirteen days in another.

  • PDF

Effect of Shading Level on Growth and Morphological Characteristics of Ligularia fischeri Seedling (차광수준이 곰취 유묘의 생장 및 형태적 특성에 미치는 영향)

  • Song, Ki Seon;Jeon, Kwon Seok;Kim, Chang Hwan;Yoon, Jun Hyuck;Park, Yong Bae;Kim, Jong Jin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.2
    • /
    • pp.88-94
    • /
    • 2014
  • This study was carried out to survey the early growth characteristics of Ligularia fischeri, plants of half-shaded grounds, primarily used as functional wild edible greens and examine its shading treatment to transplant seedling. The shading treatment was regulated with the shading level(full sunlight, 35%, 50%, 75%, and 95% of full sunlight). According to the experiment, the height was the highest under 75% of shading (17.3 cm), and root diameter was the highest under full sunlight (2.13 mm). It was found that fresh weight (leaf, shoot, root and whole) was the highest (1.784 g, 1.330 g, 0.791 g, 3.905 g respectively ) under 50% of shading. In case of dry weight, leaf, shoot and whole dry weight were surveyed the highest under 35% of shading, and root dry weight was the highest under full sunlight. It was found that S/R ratio and moisture contents (leaf, shoot, root and whole) were the highest under 95% of shading. Leaf area was the highest under 50% of shading ($39.3cm^2$) and the higher shading level, the higher SLA and LAR. It was surveyed that the higher shading level, the thinner leaf thickness. In case of root characteristics, it was showed that the relatively high height growth under 35%~75% of shading, excepting 95% of shading. As a result of surveying the whole experiment, it is concluded that the early growth of L. fischeri is more effective in producing it under 50% of shading.

Comparison of Efficacy of Overlapped Versus Long Eluting Stent in Acute Myocardial Infarction Patients with Diffuse Long Lesion (미만성 긴 병변이 있는 급성심근경색환자에서 긴 단일 용출 스텐트 시술과 중첩 스텐트 시술의 효과 비교)

  • Kim, Won Hyo;Kim, In Soo;Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.319-336
    • /
    • 2020
  • The purpose of this study was to compare the outcomes of two interventional methods, overlapping drug-eluting stents (DES) and long DES, for long-term clinical outcomes in patients with acute myocardial infarction (AMI). A total of 438 patients with AMI (65.9±11.0 years, 306 males) from June 2008 to March 2019 who had diffuse long coronary artery lesion, more than 30mm were divided into two groups; group I (overlapped DES group; n=140) and group II (long DES group; n=298). We compared the incidences of major adverse cardiac events [MACEs; cardiac death, myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST)] during 12 months between the two groups. Everolimus-eluting stent was more commonly used in group II than in group I (28.1% vs. 51.8% p<0.001). Mean lesion diameter was slightly longer in group II (3.1±0.3mm vs. 3.2±0.3mm, p=0.042), and prevalence of ACC/AHA lesion type C was higher in group I (41.7% vs. 25.4%, p<0.001). Incidences of MACEs during 12 months were higher in group I than group II (18.5% vs. 14.4%, p=0.034). The rates of cardiac death (2.1% vs. 4.4%, p=0.667), MI (5.0% vs. 2.7%, p=0.260) and stent thrombosis rate (0.7% vs. 1.7%, p=0.669) were similar between the two groups. However, TLR rate was higher in group I (10.7% vs. 5.6%, p=0.041). In multivariate logistic regression analysis, presence of diabetes mellitus [Hazard ratio (HR) 2.383, 95% confidence interval (CI) 1.332-4.260, p=0.003] and use of paclitaxel-eluting stent (HR) 2.367, 95% CI 1.371-4.086, p=0.002) were independent predictors of 12-month MACEs, without significant differences in prevalence between the two groups. In AMI patients with diffuse long lesion, TLR rate was higher in the overlapped DES group during 12-month follow-up. Presence of diabetes and use of paclitaxel-eluting stent were independent predictors of MACEs.

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

Effects of Soil Moisture and Planting Depth on the Growth of 2-year Old Ginseng Plant (Panax ginseng C. A. Meyer) (토양수분(土讓水分) 및 재식심도(栽植深度)가 저년근(低年根) 고려인삼(高麗人蔘)의 생육(生育)에 미치는 영향(影響))

  • Lee, Jong Chul;Mok, Seong Kyun;Lee, Jong Wha;Jo, Jae Seong
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.235-241
    • /
    • 1983
  • This experiment was conducted to determine the effect of soil moisture content and planting depth on the growth of 2-year old ginseng plant. The results obtained are summarized as follows; 1. When the ginseng seedlings were planted in soil by 4 to 5cm in depth, the length of leaflet and stem and the number of branch roots were significantly decreased but the stem diameter was increased. 2. Highly significant quadratic regressions were shown between soil moisture content and the growth of the stem, leaf and root of the ginseng plant. 3. Estimated amount of soil moisture for the maximum growth of the stem was 75% of field capacity, and that for length and width of the leaflet was about 65 to 66% of field capacity. Estimated soil moisture for the maximum growth of the root was about 56 to 58% of field capacity and that for increase in root weight was about 60 to 61% of field capacity. 4. Estimated soil moisture content for best growth of ginseng roots was 1 to 5% lower when the seedling was planted in 3cm depth compared with 2cm in depth. And when the amount of soil moisture was 31% of field capacity, the deep planting was adequate for good root growth. 5. Significant correlations were resulted between the dry weight of roots and the leaf length, the leaf width and the dry weight of stem and leaves. And also, significant correlations were obtained between the ratio of root dry weight to root fresh weight and the stem length, the leaf length, the leaf width and the dry weight of stem and leaves.

  • PDF

Effects of Culture Media and Growth Regulators on Callus Culture in Quercus Species (참나무류(類)의 Callus배양(培養)에 있어서 배지(培地) 및 식물생장조절물질(植物生長調節物質)의 영향(影響))

  • Lee, Jae Soon;Kim, Chi Moon
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.2
    • /
    • pp.213-231
    • /
    • 1987
  • For callus culture of leaves and internodal tissue of Quercus acutissirna Carr. and Quercus variabitisBL, MS and GD media were supplemented with combinations of different levels of growth substances such as NAA and BAP, NAA and kinetin, 2,4-D and BAP, and 2,4-D and kinetin. The results were obtained as follows; 1. The rates of formation and growth of callus were good on the GD medium supplemented with NAA and BAP, but the values were quite variable on the MS medium. Root formation occurred at the ratio of 1 : 10-100 in the concentrations of BAP and NAA. 2. The GD medium supplemented with the combination of NAA and kinetin showed 100% callus formation. The callus grew well on the other medium except for that with low concentration of NAA and kinetin. Most of roots were developed from leaf tissue cultured on GD media. 3. The GD medium supplemented with the combination of 2,4-D and BAP also showed 100% callus formation, and growth of callus was good on both of MS and GD media. In particular, the callus derived from internodal tissue showed. the most vigorous growth and reached above 22mm diameter, when they were cultured on MS media supplemented wi th the combinations of $10{\mu}M$ 2,4-D and $1.0{\mu}M$ BAP, and $10{\mu}M$ 2,4-D and $0.1{\mu}M$ BAP. 4. The GD medium supplemented with the combination of 2,4-D and kinetin showed high rate of callus formation, as compared with MS medium Callus grew well on both of MS and GD media.

  • PDF

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

Effects of Delayed Harvesting of Miscanthus spp. Risen in the Previous Year on its Current Year'S Yield and Growth Characteristics (전년도 생육 억새의 늦은 수확이 당년 생육특성과 수량에 미치는 영향)

  • Moon, Youn-Ho;Lee, Ji-Eun;Yu, Gyeong-Dan;Cha, Young-Lok;An, Gi Hong;Ahn, Joung Woong;Song, Yeon-Sang;Lee, Kyeong-Bo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.61 no.3
    • /
    • pp.215-221
    • /
    • 2016
  • This study examined the effects of delayed harvest of Miscanthus on its biomass yield and growth characteristics. The trial was conducted at a 5-year-old demonstration field, using Miscanthus sacchariflorus cv. Geodae 1 and Miscanthus ${\times}$ giganteus. Harvesting was carried out using a mower, baler, and bale picker driven by a 5-ton tractor. Harvesting dates were the $1^{st}$, $10^{th}$, and $17^{th}$ of April, which respectively corresponded with the first, mid, and last emerging dates of new shoots. The sequential changes in stem number due to delayed harvesting were investigated on April $29^{th}$, May $27^{th}$, July $22^{nd}$, and October $30^{th}$, which corresponded to the juvenile, mid, luxuriant, and senescence stem stages, respectively. Soil penetration resistance, biomass yield, and growth characteristics were investigated on October $30^{th}$. There was no difference in soil penetration resistance at a depth of 10 cm, but it increased at a depth of 20 cm in proportion to the delayed harvesting time. The sequential change in stem number due to delayed harvesting was greater in M. sacchariflorus cv. Geodae 1 than in M. ${\times}$ giganteus. In M. sacchariflorus cv. Geodae 1, which was harvested on the last emerging date of new shoots, the stem number was $169/m^2$ in the mid stage but decreased to $70/m^2$ in the luxuriant stage. The diameter of newly developed rhizomes, stem height, and biomass yield decreased in the two Miscanthus species due to delayed harvesting. The ratio of Miscanthus headings, which is a critical characteristic for landscape use, also decreased due to delayed harvesting. Heading of M. sacchariflorus cv. Geodae 1 was not observed in plots harvested on the mid and last emerging dates of new shoots.

Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants (Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구)

  • Kang, Hyun-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The objective of this study was to investigate the effects of calcium phosphate coated titanium implant surface on bone response and implant stability at early stage of healing period of 3 weeks and later healing period of 6 weeks. Material and methods: A total of 24 machined, screw-shaped implants (Dentium Co., Ltd., Seoul, Korea) which dimensions were 3.3 mm in diameter and 5.0 mm in length, were used in this research. All implants (n = 24), made of commercially pure (grade IV) titanium, were divided into 2 groups. Twelve implants (n = 12) were machined without any surface modification (control). The test implants (n = 12) were anodized and coated with thin film (150nm) of calcium phosphate by electron-beam deposition. The implants were placed on the proximal surface of the rabbit tibiae. The bone to implant contact (BIC) ratios was evaluated after 3 and 6 weeks of implant insertion. Results: The BIC percentage of calcium phosphate coated implants ($70.8{\pm}18.9%$) was significantly higher than that of machined implants ($44.1{\pm}16.5%$) 3 weeks after implant insertion (P = 0.0264). However, there was no significant difference between the groups after 6 weeks of healing (P > .05). Conclusion: The histomorphometric evaluation of implant surface revealed that; 1. After 3 weeks early healing period, bone to implant contact (BIC) percentage of calcium phosphate coated implants (70.8%) was much greater than that of surface untreated machined implants (44.1%) with P = 0.0264. 2. After 6 weeks healing period, however, BIC percentage of calcium phosphate coated implants group (79.0%) was similar to the machined only implant group (78.6%). There was no statistical difference between two groups (P = 0.8074). 3. We found the significant deference between the control group and experimental group during the early healing period of 3 weeks. But no statistical difference was found between two groups during the later of 6 weeks.

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.