Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement (마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구)

  • Rhee, Wook;Park, Sung;Kim, Jai-Moo;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.677-682
    • /
    • 2006
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

Design of a 6-axis Compliance Device with F/T Sensing for Position/Force Control (위치/힘 동시제어를 위한 F/T측정 기능을 갖는 6축 순응기구 설계)

  • Kim, Han Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.2
    • /
    • pp.63-70
    • /
    • 2018
  • In this paper, the design of a novel 6-axis compliance device with force/torque sensing capability and the experiment results on force measurement are presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, the force control method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment for more stable force control. The proposed compliance device is designed to have a diagonal stiffness matrix at the tip and uses strain gauge measurement which is robust to dust and oil. The measurement circuit is designed with low-cost IC chips however the force resolution is 0.04N.

Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement (마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구)

  • Rhee, Wook;Park, Sung;Choi, Jong-Soo;Kim, Jai-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.822-825
    • /
    • 2005
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

  • PDF

High-visibility 2D/3D LCD with HDDP Arrangement and its Optical Characterization Methods

  • Uehara, Shin-Ichi;Hiroya, Tsutomu;Kusanagi, Hidenori;Shigemura, Kouji;Asada, Hideki
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.147-150
    • /
    • 2008
  • We have developed a 3.1-inch diagonal 2D/3D LCD with a novel pixel arrangement, called HDDP (Horizontally Double-Density Pixels), for high-quality 3D images. We have improved 3D visibility by broadening the 3D viewing zone where high-quality images can be seen, and we propose optical characterization methods which can evaluate the high-visibility autostereoscopic displays correctly.

  • PDF

A Change in the Area and External Length of the Shape of Sleeve according to Arm Movements (팔 동작에 따른 소매의 착의 면적 및 외관 길이 변화)

  • Lee, Myung-Hee
    • Fashion & Textile Research Journal
    • /
    • v.12 no.5
    • /
    • pp.619-625
    • /
    • 2010
  • The purpose of this research is to analyze the shapes of blouse with above-elbow sleeves according to arm movements. The shapes include five types of the arm movement(basic posture, reach forward 45, 90, and reach lateral 45, 90) in the stand-posture, which were made by different adaptability of clothes. Experiments were conducted to figure out the dressed shape through 3-D measurement Vivid 910, and also to investigate the area of the shape of sleeves on the section map and the diagonal length of the block made by the basic section line in lateral part of sleeve with Rapid Form 2004, a software for 3-D shape analysis. The Data were analyzed by factor analysis, Anova, Duncan test, t-test. The results of this study were as follows: First, the area of sleeve was briefed 3 factor; front, center, back in sleeve. Second, there were different effect of arm movement, section level and part of shapes in the area of sleeve. Third, the diagonal length was briefed 4 factor; back, back-center, front-center, front. Forth, after t-test, there were statistically significant between the reach forward and lateral and between the angles of arm reach.

Three Degrees of Freedom Global Calibration Method for Measurement Systems with Binocular Vision

  • Xu, Guan;Zhang, Xinyuan;Li, Xiaotao;Su, Jian;Lu, Xue;Liu, Huanping;Hao, Zhaobing
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.107-117
    • /
    • 2016
  • We develop a new method to globally calibrate the feature points that are derived from the binocular systems at different positions. A three-DOF (degree of freedom) global calibration system is established to move and rotate the 3D calibration board to an arbitrary position. A three-DOF global calibration model is constructed for the binocular systems at different positions. The three-DOF calibration model unifies the 3D coordinates of the feature points from different binocular systems into a unique world coordinate system that is determined by the initial position of the calibration board. Experiments are conducted on the binocular systems at the coaxial and diagonal positions. The experimental root-mean-square errors between the true and reconstructed 3D coordinates of the feature points are 0.573 mm, 0.520 mm and 0.528 mm at the coaxial positions. The experimental root-mean-square errors between the true and reconstructed 3D coordinates of the feature points are 0.495 mm, 0.556 mm and 0.627 mm at the diagonal positions. This method provides a global and accurate calibration to unity the measurement points of different binocular vision systems into the same world coordinate system.

Measurement of Effective Linewidth for Ca-Zr Substituted YIG (Ca-Zr치환 YIG의 유효 선폭 측정)

  • 김약연;한진우;한기평;김덕준;이상석;최태구
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.1
    • /
    • pp.22-29
    • /
    • 2000
  • The effective linewidth was measured using the conventional cavity perturbation method at 9.43 GHz in room temperature for Ca-Zr substituted yttrium iron garnet plate. The experimental set-up consists of the network analyzer, the electromagnet and the cylimdrical TE001 cavity. Measurement was performed in the static magnetic field perpendicular to the sample plane. The real and imaginary parts of diagonal component of the microwave susceptibility tensor are obtained from the resonance frequency and the quality factor Q of the cavity. Variations of the effective linewidth was qualitatively explained with the spin wave scattering theory.

  • PDF

Study on Optimal Arrangements of Laser Beams in Tunable Diode Laser Absorption Spectroscopy Based Tomography (TDLAST) (레이저흡수분광 토모그래피법에서의 레이저빔의 최적 배치에 관한 연구)

  • KIM, KYUNGWON;YOON, DONGIK;CHOI, DOOWON;CHO, GYEONGRAE;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.729-737
    • /
    • 2017
  • The measurement accuracy of Tunable Diode Laser Absorption Spectroscopy based Tomography (TDLAST) for the temperature and concentration fields are dependant upon the arrangement method of the used laser beams. This paper reports on the optimization of laser beam arrangements using phantom data. It has been verified that the measurement error of the TDLAST decreased with increase of laser beam numbers. Further, it has been confirmed that perpendicular arrangements between the horizontal and the vertical laser beams without additional diagonal laser beams shows the minimum measurement errors.

Shear modulus and stiffness of brickwork masonry: An experimental perspective

  • Bosiljkov, Vlatko Z.;Totoev, Yuri Z.;Nichols, John M.
    • Structural Engineering and Mechanics
    • /
    • v.20 no.1
    • /
    • pp.21-43
    • /
    • 2005
  • Masonry is a composite non-homogeneous structural material, whose mechanical properties depend on the properties of and the interaction between the composite components - brick and mortar, their volume ratio, the properties of their bond, and any cracking in the masonry. The mechanical properties of masonry depend on the orientation of the bed joints and the stress state of the joints, and so the values of the shear modulus, as well as the stiffness of masonry structural elements can depend on various factors. An extensive testing programme in several countries addresses the problem of measurement of the stiffness properties of masonry. These testing programs have provided sufficient data to permit a review of the influence of different testing techniques (mono and bi-axial tests), the variations caused by distinct loading conditions (monotonic and cyclic), the impact of the mortar type, as well as influence of the reinforcement. This review considers the impact of the measurement devices used for determining the shear modulus and stiffness of walls on the results. The results clearly indicate a need to re-assess the values stated in almost all national codes for the shear modulus of the masonry, especially for masonry made with lime mortar, where strong anisotropic behaviour is in the stiffness properties.

A Study on Electric Properties of Polyamide Film due to Temperature Change

  • Lee, Sung Ill
    • Elastomers and Composites
    • /
    • v.54 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • In this study, we measured the leakage current at $30{\sim}80^{\circ}C$ and $90{\sim}170^{\circ}C$ under a voltage of 200~980 V applied to samples (ordinary temperature) and polyamide film specimens degraded at $170^{\circ}C$ for 20 minute respectively. After the specimen was degraded at $130^{\circ}C$ and $50^{\circ}C$, a voltage of 200 to 800 V was applied for 10 to 60 minutes. The measurement of the leakage current resulted in the following conclusions. In the case of using Al and Cu as the main electrode, it was confirmed that the leakage current also increased in high temperatures as the voltage increased. Regardless of the type of main electrode, when the temperature was constant at $130^{\circ}C$ and $50^{\circ}C$, the leakage current increased as the voltage increased, and gradually decreased with time. As a result of the FTIR measurement, the main absorption of the infrared absorption spectrum was C=O at about $1650cm^{-1}$ and N-H diagonal vibration occurred at around $1550cm^{-1}$. There was no change in the material, so no effect of temperature was observed. By the results of SEM measurements, as the temperature of degradation increases, cracks in the specimen disappear. This may be because the amide bond (-CO-NH-) is absorbed by the material.