DOI QR코드

DOI QR Code

Study on Optimal Arrangements of Laser Beams in Tunable Diode Laser Absorption Spectroscopy Based Tomography (TDLAST)

레이저흡수분광 토모그래피법에서의 레이저빔의 최적 배치에 관한 연구

  • KIM, KYUNGWON (Division of Refrigeration and Air-conditioning Eng., Graduate School, Korea Maritime and Ocean University) ;
  • YOON, DONGIK (Division of Refrigeration and Air-conditioning Eng., Graduate School, Korea Maritime and Ocean University) ;
  • CHOI, DOOWON (Division of Electronics and Communication Eng., Graduate School, Korea Maritime and Ocean University) ;
  • CHO, GYEONGRAE (Division of Mechanical Eng., Graduate School, Korea Maritime and Ocean University) ;
  • DOH, DEOGHEE (Division of Mechanical Eng., Graduate School, Korea Maritime and Ocean University)
  • 김경원 (한국해양대학교 냉동공조공학과) ;
  • 윤동익 (한국해양대학교 냉동공조공학과) ;
  • 최두원 (한국해양대학교 전자통신공학과) ;
  • 조경래 (한국해양대학교 공과대학 기계공학부) ;
  • 도덕희 (한국해양대학교 공과대학 기계공학부)
  • Received : 2017.09.29
  • Accepted : 2017.12.29
  • Published : 2017.12.31

Abstract

The measurement accuracy of Tunable Diode Laser Absorption Spectroscopy based Tomography (TDLAST) for the temperature and concentration fields are dependant upon the arrangement method of the used laser beams. This paper reports on the optimization of laser beam arrangements using phantom data. It has been verified that the measurement error of the TDLAST decreased with increase of laser beam numbers. Further, it has been confirmed that perpendicular arrangements between the horizontal and the vertical laser beams without additional diagonal laser beams shows the minimum measurement errors.

Keywords

References

  1. Y. Deguchi, "Industrial applications of Laser Diagnostics", CRS Press: Taylor & Francis, 2011.
  2. Y. Zaatar, J, Bechara, A. Khoury, D. Zaouk, and J. P. Charles, "Diode Laser Sensor for Process Control and Environmental Monitoring", Applied Energy, Vol. 65, 2000, pp. 107-113. https://doi.org/10.1016/S0306-2619(99)00090-2
  3. D. W. Choi, M. G. Jeon, G. R. Cho, T. Kamimoto, Y. Deguchi, and D. H. Doh, "Performance Improvement in Temperature Reconstructions of 2-D Tunable Diode Laser Absorption Spectroscopy (TDLAS)", Journal of Thermal Science, Vol. 25, No. 1, 2016, pp. 84-89. https://doi.org/10.1007/s11630-016-0837-z
  4. D. W. Choi, M. G. Jeon, G. R. Cho, T. Kamimoto, Y. Deguchi, and D. H. Doh, "Developments of a Cross-Correlation Calculation Algorithm for Gas Temperature Distributions Based on TDLAS", Trans. of the Korean Hydrogen and New Energy Society, Vol. 27, No. 1, 2016, pp. 127-134. https://doi.org/10.7316/KHNES.2016.27.1.127
  5. D. W. Choi, G. R. Cho, Y. Deguchi, T. S. Baek, and D. H. Doh, "Study on Optimal Coefficients of Line Broadening Function for Performance Enhancements of CT-TDLAS", Trans. of the Korean Hydrogen and New Energy Society, Vol. 27, No. 6, 2016, pp. 773-782. https://doi.org/10.7316/KHNES.2016.27.6.773
  6. M. G. Jeon, Y. Deguchi, T. Kamimoto, D. H. Doh, and G. R. Cho, "Performances of new reconstruction algorithms for CT-TDLAS (computer tomography-tunable diode laser absorption spectroscopy)", Applied Thermal Engineering, Vol. 115, 2017, pp. 1148-1160. https://doi.org/10.1016/j.applthermaleng.2016.12.060
  7. L. S. Rothman, I. E. Gordon, A. Barbe, D. Chris Benner, P. F. Bernath, M. Birk, V. Boudon, L. R. Brown, A. Campargue, J. P. Champion, K. Chance, L. H. Coudert, V. Dana, V. M. Devi, S. Fally, J. M. Flaud, R. R. Gamache, A. Goldman, D. Jacquemart,I. Kleiner, N. Lacome, W. J. Lafferty, J. Y. Mandin, S. T. Massie, S. N. Mikhailenko, C. E. Miller, N. Moazzen-Ahmadi, O. V. Naumenko, A. V. Nikitin, J. Orphal, V. I. Perevalov, A. Perrin, A. Predoi-Cross, C. P. Rinsland, M. Rotger, M. Simeckova, M. A. H. Smith, K. Sung, S. A. Tashkun, J. Tennyson, R. A. Toth, A. C. Vandaele, and J. Vander Auwera, "The HITRAN 2008 molecular spectroscopic database", J. Quant. Spectrosc. Radiat. Transfer, Vol. 110, No. 9-10, 2009, pp. 533-572. https://doi.org/10.1016/j.jqsrt.2009.02.013
  8. M. Jiang and G. Wang, "Convergence of the simultaneous algebraic reconstruction technique (SART)", IEEE Transactions on Image Processing, Vol. 12, No. 8, 2003, pp. 957-961. https://doi.org/10.1109/TIP.2003.815295
  9. T. Kamimoto, Y. Deguchi, and Y. Kiyota, "High temperature field application of two dimensional temperature measurement technology using CT tunable diode laser absorption spectroscopy", Flow Measurement and Instrumentation, Vol. 46, 2015, pp. 51-57. https://doi.org/10.1016/j.flowmeasinst.2015.09.006