Analysis of Aging Insulation Characteristics of 3.3[kV] Class Induction Motor with AC Breakdown Test (절연파괴시험법을 이용한 3.3[kV] 유도전동기의 절연물 열화특성 분석)

  • Lee, Ju;Kim, Hyun-Il;Kim, Youn-Hyun;Son, Yeoung-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.141-149
    • /
    • 2007
  • This paper introduce to improve the reliability of the expected service life and the insulation condition evaluation of the high voltage induction motors by assessing, comparing and analyzing the correlation between the dielectric properties of the off-line insulation diagnostic test and dielectric strength on the insulation breakdown test. The insulation diagnostic tests include insulation resistance, polarization index(P.I.), dissipation factor($tan{\delta}$), maximum partial discharges($Q_{max}$) and AC breakdown test. This study evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor. On the basis of these test results, we expect that this study can be used for effectively assessing the results of insulation diagnostic tests for similar class induction motors in service at industrial field.

Screening Sarcopenia in Rural Community-Dwelling Older Adults in Korea

  • KIM, Mi-Kyoung;LEE, Ji-Yeon;GIL, Cho-Rong;KIM, Bo-Ram;CHANG, Hee-Kyung
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.64-76
    • /
    • 2020
  • Purpose: Several screening tools have been developed to identify sarcopenia in rural community-dwelling older adults. We aimed to compare the diagnostic accuracy of two such tools, namely the SARC-F and SARC-CalF assessments. Methods: This cross-sectional study on 388 community-dwelling older adults comprised 254 women and 134 men with a mean age of 77.8 ± 6.26 year in Korea. We assessed muscle mass, muscle strength, and physical performance using a bioimpedance analysis device, hydraulic hand dynamometer, and 4 m gait speed test, respectively. Three widely-used diagnostic criteria [the Asian Working Group for Sarcopenia (AWGS), European Working Group on Sarcopenia in Older People, and the International Working Group on Sarcopenia] were applied. Sensitivity and specificity analyses were performed on the SARC-CalF and SARC-F tests. We used receiver-operating characteristic curves and the area under the curves (AUCs) to compare the diagnostic accuracy of the assessments with regard to sarcopenia. Results: An analysis using four sets of diagnostic criteria showed that the prevalence of sarcopenia was 27.6% to 41.0%. Using the AWGS 2019 criteria as a reference standard, the SARC-CalF had a sensitivity of 83.02% and a specificity of 53.71% in the entire study population, whereas the SARC-F had a sensitivity of 79.87% and a specificity of 41.92%. The AUCs for the SARC-CalF and SARC-F tests were 0.725 (95% confidence interval 0.678-0.769) and 0.645 (95% confidence interval 0.595-0.693), respectively (p<001). In the analyses using the other three diagnostic criteria, similarity was also confirmed. Conclusion: SARC-CalF showed better sensitivity than did SARC-F when diagnosing sarcopenia in rural community-dwelling older adults. Further studies are needed to verify this finding in different populations.

Clinical Usefulness of LabChip Real-time PCR using Lab-On-a-Chip Technology for Diagnosing Malaria

  • Kim, Jeeyong;Lim, Da Hye;Mihn, Do-CiC;Nam, Jeonghun;Jang, Woong Sik;Lim, Chae Seung
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.1
    • /
    • pp.77-82
    • /
    • 2021
  • As malaria remains a major health problem worldwide, various diagnostic tests have been developed, including microscopy-based and rapid diagnostic tests. LabChip real-time PCR (LRP) is a small and portable device used to diagnose malaria using lab-on-a-chip technology. This study aimed to evaluate the diagnostic performance of LRP for detecting malaria parasites. Two hundred thirteen patients and 150 healthy individuals were enrolled from May 2009 to October 2015. A diagnostic detectability of LRP for malaria parasites was compared to that of conventional RT-PCR. Sensitivity of LRP for Plasmodium vivax, P. falciparum, P. malariae, and P. ovale was 95.5%, 96.0%, 100%, and 100%, respectively. Specificity of LRP for P. vivax, P. falciparum, P. malariae, and P. ovale was 100%, 99.3%, 100%, and 100%, respectively. Cohen's Kappa coefficients between LRP and CFX96 for detecting P. vivax, P. falciparum, P. malariae, and P. ovale were 0.96, 0.98, 1.00, and 1.00, respectively. Significant difference was not observed between the results of LRP and conventional RT-PCR and microscopic examination. A time required to amplify DNAs using LRP and conventional RT-PCR was 27 min and 86 min, respectively. LRP amplified DNAs 2 times more fast than conventional RT-PCR due to the faster heat transfer. Therefore, LRP could be employed as a useful tool for detecting malaria parasites in clinical laboratories.

Allergy tests in clinical practice (알레르기 검사의 실제)

  • Lee, Jaechun
    • Journal of Medicine and Life Science
    • /
    • v.15 no.1
    • /
    • pp.1-5
    • /
    • 2018
  • Allergy is conditions when a hypersensitivity reaction happens with a certain element, called as an allergen, which is commonly not reactive to ordinary individuals. Allergic diseases involve various organs or systems in the body. The purpose of allergy tests is to make a diagnosis of allergic diseases and to identify the affecting allergens. In vivo tests, more relevant in clinical situation, include skin test, patch test and provocation test. In in vitro tests, there are specific IgE test, histamine releasing assay, and lymphocyte activation test, safer and more objective than in vivo tests. In the view point of clinical practice, skin test, provocation test, total IgE test and specific IgE test were reviewed in depth.

Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

How accurate are rapid diagnostic tests for covid-19? (코로나19 신속진단검사는 얼마나 정확한가?)

  • Yeo, In-Kwon
    • The Korean Journal of Applied Statistics
    • /
    • v.35 no.3
    • /
    • pp.435-443
    • /
    • 2022
  • In this paper, using Covid-19 diagnostic data provided by the Korea Disease Control and Prevention Agency (KDCA), we examine the probability of confirmed cases and the probability of actually being confirmed when the rapid test is negative according to the sensitivity and specificity of the rapid diagnostic kit. When we know the conditional probability of confirmation given a positive test, we induce the relationship between sensitivity and specificity, and compute the actual sensitivity of the rapid diagnosis kit based on the data of KDCA.

Diagnostic Performance of Three Rapid Diagnostic Test Kits for Malaria Parasite Plasmodium falciparum

  • Park, Seo Hye;Jegal, Seung;Ahn, Seong Kyu;Jung, Haneul;Lee, Jinyoung;Na, Byoung-Kuk;Hong, Sung-Jong;Bahk, Young Yil;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.2
    • /
    • pp.147-152
    • /
    • 2020
  • Malaria is a potent burden on public healthcare worldwide due to requiring rapid diagnosis and treatment. Nowadays, prompt diagnosis with rapid diagnostic tests (RDTs) has been widely accepted as an effective diagnostic technique in malaria-endemic countries, primarily due to their easy operation, fast output, and straightforward interpretation. The global availability and use of RDTs have gradually grown over recent decades as field-applicable diagnostic tests for the reliable confirmation of malaria infection and proper case management. This study was conducted to evaluate diagnostic performance of 3 commercially available malaria RDT kits : BIOCREDITTM Malaria Ag Pf(pLDH), Malaria Ag Pf(pLDH/pHRPII), and Malaria Ag Pf/Pv(pLDH/pLDH) (where pLDH and pHRPII stand for plasmodium lactate dehydrogenase and histidine-rich protein 2, respectively) for the specific detection of Plasmodium falciparum. A total of 1,129 blood samples including 95 blood samples, confirmed as vivax malaria infection by microscopic examinations and a nested-PCR method, were tested for falciparum malaria infection. The overall sensitivity and specificity of Malaria Ag Pf(pLDH/pHRPII), Malaria Ag Pf/Pv(pLDH/pLDH), and Pf(pLDH) for P. falciparum were 99.0% and 100%, 95.8% and 100%, and 100% and 100%, respectively. It is proposed that the 3 RDT kits perform reliable level of diagnostic accuracy of detection for P. falciparum parasites.

Mathematical Preparedness Predicts College Grades in Physics Better than Physics Preparedness: the Predictive Validity of the Mathematical Diagnostic Test on the Freshmen's Physics Grades (물리보다 수학을 잘 해야 물리를 잘 한다: 입학 전 수학진단점수의 일반물리학 성취도 예측타당성 검증)

  • Shin, Yunkyoung;Park, Kyuyeol;Lee, Ah-reum;Jung, Jongwon
    • Journal of Engineering Education Research
    • /
    • v.22 no.4
    • /
    • pp.22-31
    • /
    • 2019
  • This study aims to elucidate the relationship between physics and mathematics to predict achievement for the college level of engineering courses. For the last 4 years, more than 3,000 engineering college freshmen of this study took the diagnostic tests on three subjects, which were physics, mathematics, and chemistry before enrollment. We studied how strongly these diagnostic scores can predict each general college course grades. The correlation between the physics diagnostic scores and the course grades in physics was .264, which was significantly lower than the correlation between the mathematics scores and the physics grades, .311. This stronger prediction of the mathematical diagnostic scores for the general course grades was not found when predicting the grades in chemistry. We therefore conclude that mathematical preparation can unexpectedly predict future achievement in physics better than physics preparation due to the academic interrelationships between mathematics and physics.

Neonatal Coagulation Disorder: Diagnostic Approaches for Bleeding Neonates (신생아 혈액 응고질환: 출혈 경향을 보이는 신생아에 대한 진단적 접근)

  • Kim, Chun-Soo
    • Neonatal Medicine
    • /
    • v.18 no.1
    • /
    • pp.6-13
    • /
    • 2011
  • All newborn infants with clinically significant bleeding should be evaluated for a hemostatic deficit. Medical history should include the following data: familial bleeding disorders, maternal illness and medication, age of bleeding onset, and prophylactic administration of vitamin K. The first essential step for evaluating bleeding neonates is determining whether the baby is sick or well. The physician should also evaluate the extent of the bleeding, features of bleeding lesions, and other abnormal findings from the physical examination. Skeletal anomalies may provide diagnostic clues. Depending on the clinical features and results of screening tests, other tests including coagulation factors may be useful for determining the diagnosis. All laboratory results must be considered in the context of age-related reference values. The platelet function analyzer provides a promising alternative to bleeding time. Fibrin degradation products and D-dimers are used for screening and specially testing fibrinolytic activity, respectively. The Apt test may help to rule out factors derived from maternal blood. Radiologic imaging studies are important because asymptomatic intracranial hemorrhages are common in neonates.

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF