• Title/Summary/Keyword: Diagnostic specificity

Search Result 972, Processing Time 0.032 seconds

Radioimmunoscintigraphy Using $^{99m}Tc-anti-CEA\;F(ab')_2$ Fragment in Rectal Cancer and a Pilot Study for Radioimmunoguided Surgery (직장암에서 $^{99m}Tc$-항CEA 항체 $F(ab')_2$ 분절을 이용한 수술 전 방사면역신티그라피 및 방사면역지침수술에 관한 기초 연구)

  • Ryu, Jin-Sook;Kim, Jin-Choen;Kim, Chang-Nam;Gong, Gyung-Yub;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.243-251
    • /
    • 2000
  • Purpose: This prospective study was performed to evaluate the usefulness of preoperative radioimmunoscintigraphy and intraoperative scintimetric examination (radioimmunoguided surgery: RIGS) using $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment. Materials and Methods: Nineteen patients with rectal cancer underwent preoperative whole body planar scintigraphy at 4 hours after injection of $^{99m}Tc-anti-CEA\;F(ab')_2$ fragment and SPECT imaging at 18 hours. Surgical operation was performed at 24 hours after injection. During laparotomy, radioactivities from intraabdominal viscera were measured by gamma probe. The radioactivities from excised tumor and lymph nodes were also measured and compared with pathology. Results: All nineteen patients were confirmed to have adenocarcinomas in the rectum. Twenty-seven of 97 excised lymph node groups had metastasis and 2 patients had liver metastasis in pathology Preoperative radioimmunoscintigraphy detected primary tumors in 11 patients (sensitivity 55%) and it could not detect any lymph nodes or liver metastasis. All patients showed high radioactivity in the kidneys, liver, spleen, and major vessels in intraoperative measurement by gamma probe, and tumor activity was not discriminated from background activity However, radioactivity from excised tumor was higher than normal rectum (T/B ratio; $3.47{\pm}2.25$). When excised lymph node activity/background activity ratio >1.5 was considered as positive criteria of metastasis, sensitivity, specificity, positive and negative predictive values were 78.6%, 73.9%, 55.0% and 89.5%, respectively. Conclusion: Radioimmunoscintigraphy using $^{99m}Tc-anti-CEA\;F(ab')_2$ has no additional value for preoperative staging and use of early RIGS using $^{99m}Tc-anti-CEA\;F(ab')_2$ is inappropriate. For early RIGS using $^{99m}Tc$ labeled antibodies in rectal cancer patients, further development of more specific antibodies and methods to reduce background activity are needed.

  • PDF

Diagnostic Performance of HPV E6/E7 mRNA and HPV DNA Assays for the Detection and Screening of Oncogenic Human Papillomavirus Infection among Woman with Cervical Lesions in China

  • Wang, Hye-young;Lee, Dongsup;Park, Sunyoung;Kim, Geehyuk;Kim, Sunghyun;Han, Lin;Yubo, Ren;Li, Yingxue;Park, Kwang Hwa;Lee, Hyeyoung
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7633-7640
    • /
    • 2015
  • Background: Human papillomavirus (HPV) is the most common sexually transmitted infection worldwide and it is responsible for most cases of cervical uterine cancer. Although HPV infections of the cervix do not always progress to cancer, 90% of cervical cancer cases have been found to be associated with high risk HPV (HR-HPV) infection. HPV DNA testing is widely used, along with Papanicolaou (Pap) testing, to screen for cervical abnormalities. However, there are no data on the prevalence of genotype-specific HPV infections assessed by measuring HPV E6/E7 mRNA in women representative of the Chinese population across a broad age range. Materials and Methods: In the present study, we compared the results with the CervicGen HPV RT-qDx assay, which detects 16 HR-HPV genotypes (Alpha-9: HPV 16, 31, 33, 35, 52, and 58; Alpha-7: HPV 18, 39, 45, 51, 59, and 68; and Alpha-5, 6: HPV 53, 56, 66, and 69), and the REBA HPV-ID assay, which detects 32 HPV genotypes based on the reverse blot hybridization assay (REBA) for the detection of oncogenic HPV infection according to cytological diagnosis. We also investigated the prevalence and genotype distribution of HPV infection with a total of 324 liquid-based cytology samples collected in western Shandong province, East China. Results: The overall HPV prevalences determined by HPV DNA and HPV E6/E7 mRNA assays in this study were 79.9% (259/324) and 55.6% (180/324), respectively. Although the positivity of HPV E6/E7 mRNA expression was significantly lower than HPV DNA positivity, the HPV E6/E7 mRNA assay showed greater specificity than the HPV DNA assay (88.6% vs. 48.1%) in normal cytology samples. The prevalence of Alpha-9 (HPV 16, 31, 33, 35, 52, and 58) HPV infection among these women accounted for up to 80.3% and 76.1% of the high-grade lesions detected in the HPV mRNA and DNA tests, respectively. The HR-HPV genotype distribution, based on HPV DNA and E6/E7 mRNA expression by age group in patients with cytologically confirmed lesions, was highest in women aged 40 to 49 years (35.9% for cytologically confirmed cases, Pearson correlation r value=0.993, p<0.001) for high-grade lesions. Among the oncogenic HR-HPV genotypes for all age groups, there was little difference in the distribution of HPV genotypes between the HPV DNA (HPV -16, 53, 18, 58, and 33) and HPV E6/E7 mRNA (HPV -16, 53, 33, 58, and 18) assays. HPV 16 was the most common HPV genotype among women with high-grade lesions. Conclusions: Our results suggest that the HPV E6/E7 mRNA assay can be a sensitive and specific tool for the screening and investigation of cervical cancer. Furthermore, it may provide useful information regarding the necessity for early cervical cancer screenings and the development of additional effective HPV vaccines, such as one for HPV 53 and 58. Additionally, gaining knowledge of HPV distribution may also inform us about ecological changes in HPV after the vaccination.

Staging of Esophageal Cancer Using Positron Emission Tomography : Comparing to Computed Tomography (양전자방출단층촬영술(PET)을 이용한 식도암 환자의 병기 결정 -전산화단층촬영술(CT)과의 비교-)

  • 심영목;박승준;김병태;김성철
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.388-393
    • /
    • 1999
  • Background: Correct preoperative staging of esophageal cancer is a prerequisite for adequate treatment. We prospectively compared the accuracy of positron emission tomography (PET) with [fluorine-18]FDG in the staging of esophageal cancer to that of computed tomography (CT). Material and Method: The findings of FDG PET and of chest CT including lower neck and the upper abdomen of 20 biopsy-proven squamous cell carcinoma patients (male, 19; female, 1; mean age, 61) were compared with the pathologic findings obtained from a curative esophagectomy with lymph node dissection. Result: The sensitivities of FDG PET and CT for diagnosis of primary tumor were the same, 90.0% (18/20). Both FDG PET and CT failed to show the primary tumor in 2 of 20 patients; one had a 1cm sized carcinoma in situ and the other had T1 stage cancer. By using the results of the pathologic examinations of 193 removed lymph node groups, we calculated the diagnostic sensitivities, specificities and accuracies of PET and CT (*$\chi$2 p < 0.005). Sensitivity** Specificity Accuracy* PET 55.6%(30/54) 97.1%(135/139) 85.5%(165/193) CT 13.0%(7/54) 98.6%(137/139) 74.6%(144/193) One of four patients with a false-positive for PEThad had active pulmonary tuberculosis. Among the 24 tumor involved lymph node groups, PET failed to show tumor metastasis in 5 lymph node groups abutting the tumor and in 14 lymph node groups located where the decay correction was not performed. Conclusion: Based on the above findings, it is suggested that [F-18]FDG-PET is superior to CT in the detection of nodal metastases and in the staging of patients with esophageal cancer.

  • PDF

Soluble Interleukin-2 Receptor(sIL-2R) Levels in Patients Tuberculous Pleurisy VS Nontuberculous Pleurisy (결핵성 늑막삼출과 비결핵성 늑막삼출에서의 가용성 Interleukin-2 수용체의 농도)

  • Lim, Hyun-Oak;Ham, Jong-Yeol;Shim, Dae-Seok;Hwang, Young-Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.135-143
    • /
    • 1994
  • Background: The cell mediated immunity has an important role in the pathogenesis of tuberculosis. sIL-2R has been known as a sensitive marker of T lymphocyte activation Elevated serum levels of sIL-2R have been found in patients with lymphoproliferative disorders, organ transplantation, autoimmune diseases, and various granulomatous diseases. Elevated levels of sIL-2R have been also found in the serum and pleural fluid of the patients with tuberculosis. To evaluate the diagnostic value of sIL-2R in the differentiation of tuberculous pleurisy and nontuberculous pleurisy. We measured the level of sIL-2R in the sera and pleural fluids of 12 patients with tuberculous pleurisy and 32 patients with nontuberculous pleurisy. Method: Samples of pleural fluid and serum were centrifuged at 2500 rpm for 10 min to remove cell pellets. Soluble IL-2R was measured with a sandwitch enzyme immunoassay using the Cellfree(r) Interleukin-2 Receptor Test kit(T-cell science,Inc. Cambridge, MA). Results: The results obtained were as follows: 1) The sIL-2R level in pleural fluid of the patients with tuberculous pleurisy was higher than that of patients with nontuberculous pleurisy(P<0.005). 2) When the sIL-2R level above 5,000 u/ml in pleural fluid was used as the cut-off value to diagnose tuberculous pleurisy, it had a sensitivity of 84.6% and a specificity of 90.9%. 3) The sIL-2R level in the sera of the patients with tuberculous pleurisy was higher than that of patients with bacterial pleural effusions and normal control group(P<0.05) and there was no difference of levels compared with malignant pleural effusions and transudative pleural effusions(P>0.05). 4) In patients with tuberculous pleurisy, the mean concentration of sIL-2R in pleural fluid was higher than that in serum(P<0.005). Conclusion: These findings suggest that the measurement of elevated levels of pleural fluid sIL-2R in tuberculous pleurisy may be useful in the differential diagnosis between patients with tuberculous pleurisy and nontuberculous pleurisy.

  • PDF

Usefulness of PCR Test for M. tuberculosis for the Differentiation of Pulmonary Tuberculosis and Nontuberculous Mycobacterial Lung Disease in Patients with Smear-Positive Sputum (객담 도말 양성 환자에서 폐결핵과 비결핵 항산균 폐질환의 구별을 위한 결핵균 PCR 검사의 유용성)

  • Yu, Chang-Min;Koh, Won-Jung;Ryu, Yon Ju;Jeon, Kyeongman;Choi, Jae Chol;Kang, Eun Hae;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung;Lee, Jang Ho;Ki, Chang-Seok;Lee, Nam Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.6
    • /
    • pp.528-534
    • /
    • 2004
  • Background : Microscopic examination of sputum smears for acid-fast bacilli (AFB) is the most important and rapid diagnostic test for pulmonary tuberculosis. However, the AFB observed on the smear may represent either M. tuberculosis or nontuberculous mycobacteria (NTM). This study examined the clinical usefulness of a polymerase chain reaction test for M. tuberculosis (TB-PCR) for the differentiation of pulmonary tuberculosis and NTM lung disease in patients with smear-positive sputums in a tertiary hospital in Korea. Material and Methods : From January, 2003 to December, 2003, 826 AFB smear-positive and culture-positive sputum specimens were collected from 299 patients. Results : NTM were recovered from 26.6% (220/826) of the smear-positive sputum specimens and 23.4% (70/299) of the patients with smear-positive sputum. All the patients with isolated NTM had clinically significant NTM lung disease; 38 patients (54.3%) had M. avium and 26 patients (37.1%). had M. abscessus. In the patients with pulmonary tuberculosis, 78.7% of the patients (74/94) showed TB-PCR positivity, and all the patients with NTM lung disease showed negative results on the TB-PCR test (p<0.001). A positive result of the TB-PCR test on the sputum or bronchial washing fluid specimens was able to predict pulmonary tuberculosis with 88.4% sensitivity, 100% specificity, a 100% positive predictive value and a 79.7% negative predictive value for the patients with smear-positive sputum. Conclusion : The TB-PCR test for sputum specimens or bronchial washing fluid specimens could be useful for differentiating pulmonary tuberculosis and NTM lung disease for the patients with smear-positive sputum in Korea.

NT-proBNP as a useful tool in diagnosing incomplete Kawasaki disease (불완전 가와사끼병에서 NT-proBNP의 진단적 역할)

  • Lee, Dong-Won;Kim, Yeo-Hyang;Hyun, Myung-Chul;Kwon, Tae-Chan;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.519-524
    • /
    • 2010
  • Purpose : To determine the efficacy of the N-terminal fragment of B-type natriuretic peptide (NT-proBNP) as a useful diagnostic method in children with incomplete Kawasaki disease (KD). Methods : Ninety-six patients who were diagnosed as having KD between January 2008 and June 2009 were enrolled in the study. American Heart Association recommendations for diagnosis were used, and patients were divided into the complete KD and incomplete KD groups. Blood tests including NT-proBNP were performed on admission day. Nineteen patients who had other febrile diseases other than KD were enrolled as control. Results : Thirty-three patients (34%) had incomplete KD. Change in the lips and oral cavity and conjunctivitis were the most common clinical features, but their frequency was lower than complete KD (76% vs 98%, 76% vs 90%). Patients with incomplete KD exhibited significantly higher NT-proBNP level than that of control ($1,407.7{\pm}1633.5pg/mL$ vs $126.2{\pm}135.5pg/mL$, $P$<0.001). An NT-proBNP cutoff value of 158 pg/mL provided a sensitivity of 81% and a specificity of 74% for diagnosis of incomplete KD. Conclusion : NT-proBNP assay can be clinically useful for the diagnosis of incomplete KD, if the patient has persistent fever, change in the lips and oral cavity, and conjunctivitis, and if the patient with those symptoms is suspected to have incomplete KD.

T1-201 Per Rectum Scintigraphy in Chronic Liver Disease: Assessment of T1-201 Uptake Indices (만성 간질환에서의 T1-201 경직장 문맥 신티그라피: T1-201 섭취 지표의 평가)

  • Moon, Won-Jin;Choi, Yun-Young;Cho, Suk-Shin;Lee, Min-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.49-56
    • /
    • 1999
  • Purpose: Heart to liver ratio on T1-201 per rectal scintigraphy (shunt index) is known to be useful in the assessment of portal systemic shunt. We assessed T1-201 uptake pattern and early liver/heart uptake rate of T1-201 and correlated with shunt index in patients with chronic active hepatitis (CAH) and liver cirrhosis (LC). Materials and Methods: Fifty eight patients with biopsy-proven chronic liver disease (35 with CAH, 23 with LC) underwent T1-201 per rectum scintigraphy after instillation of 18.5 MBq of T1-201 into the upper rectum. We evaluated hepatic uptake (type 1 : homogeneous, 2: inhomogeneous segmental, 3: inhomogeneous nonsegmental) and extrahepatic uptake of spleen, heart and kidney (grade 0: no uptake, 1: less than liver, 2: equal to liver, 3: greater than liver). We measured the early liver/heart uptake rate (the slope of the liver to heart uptake ratio for 10 min) and shunt index (heart to liver uptake ratio). T1-201 uptake pattern and early liver/heart uptake rate of T1-201 was correlated with the pathologic diagnosis and shunt index. Results: Hepatic uptake patterns of type 1 and 2 were dominant in CAH (CAH: 27/35, LC. 8/23), and type 3 in LC (CAH: 8/35, LC: 15/23)(p<0.005). The grades of extrahepatic uptake were higher in LC than in CAH (spleen: p<0.001, other soft tissue: p<0.005). The early liver/heart uptake rate of CAH ($0.110{\pm}0.111$) was significantly higher than that of LC ($0.014{\pm}0.090$)(p<0.001). The sensitivity and specificity of the early liver/heart uptake rate were 77.7% and 67.7% in differentiating LC from CAH. There was negative correlation between early liver/heart uptake rate and shunt index (r=-0.3347, p<0.01). Conclusion: Hepatic and extrahepatic uptake pattern and early liver/heart uptake rate on T1-201 per rectum scintigraphy are useful in the assessment of portal systemic shunt in patients with chronic liver disease.

  • PDF

The Differentiation of Benign from Maligant Soft Tissue Lesions using FDG-PET: Comparison between Semi-quantitative Indices (FDG-PET을 이용한 악성과 양성 연부조직 병변의 감별: 반정량적 지표간의 비교)

  • Choi, Joon-Young;Lee, Kyung-Han;Choe, Yearn-Seong;Choi, Yong;Kim, Sang-Eun;Seo, Jai-Gon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.90-101
    • /
    • 1997
  • The purpose of this study is to evaluate the diagnostic accuracy of various quantitative indices for the differentiation of benign from malignant primary soft tissue tumors by FDG-PET. A series of 32 patients with a variety of histologically or clinically confirmed benign (20) or malignant (12) soft tissue lesions were evaluated with emission whole body (5min/bed position) PET after injection of [$^{18}F$]FDG. Regional 20min transmission scan for the attenuation correction and calculation of SUV was performed in 16 patients (10 benign, 6malignant) followed by dynamic acquisition for 56min. Postinjection transmission scan for the attenuation correction and calculation of SUV was executed in the other 16 patients (10 benign, 6 malignant). The following indices were obtained. the peak and average SUV (pSUV, aSUV) of lesions, tumor-to-background ratio acquired at images of 51 min p.i. ($TBR_{51}$), tumor-to-background ratio of areas under time-activity curves ($TBR_{area}$) and the ratio between the activities of tumor ROI at 51 min p. i. and at the time which background ROI reaches maximum activity on the time-activity curves ($T_{51}/T_{max}$). The pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ in malignant lesions were significantly higher than those in benign lesions. We set the cut-off values of pSUV, aSUV, $TBR_{51},\;TBR_{area}$ and $T_{51}/T_{max}$ for the differentiation of benign and malignant lesions at 3.5, 2.8, 5.1, 4.3 and 1.55, respectively. The sensitivity, specificity and accuracy were 91.7%, 80.0%, 84.4% by pSUV and aSUV, 83.3%, 85.0%, 84.4% by $TBR_{51}$, 83.3%, 100%, 93.8% by $TBR_{area}$ and 66.7%, 70.0%, 68.8% by $T_{51}/T_{max}$. The time-activity curves did not give additional information compared to SUV or TBR. The one false negative was a case with low-grade fibrosarcoma and all four false positives were cases with inflammatory change on histology. The visual, analysis of FDG-PET also detected the metastatic lesions in malignant cases with comparable accuracy In conclusion, all pSUV, aSUV, $TBR_{51}$, and $TBR_{area}$ are useful metabolic semi-quantitative indices with good accuracy for the differentiation of benign from malignant soft-tissue lesions.

  • PDF

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Clinical Significance of Follow-up CT after Ultrasonography for Acute Appendicitis in Children (소아 급성 충수염에서 복부초음파 이후 전산화단층촬영 추적 검사의 임상적 의의)

  • Yu, Seong-Keun;Moon, Jin-Soo;Kim, Nam-Hee;Hwang, Jong-Hee;Nam, Seung-Yeon;Kim, Dong-Wook;Lee, Chong-Guk;Seo, Jung-Wook;Heo, Tae-Gil
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.36-43
    • /
    • 2007
  • Purpose: The ultrasonography (USG) and computed tomography (CT) are popular diagnostic tools for the diagnosis of acute appendicitis in children, but there are many debates about their clinical significance. The purpose of this study is to clarify the clinical significance of USG, CT and follow-up CT performed subsequently to USG, especially in perforated acute appendicitis in children. Methods: We have reviewed 419 cases of surgically confirmed acute appendicitis in children under the age of sixteen, who had been treated in Inje University Ilsan Paik Hospital from March 2002 to February 2006. All the clinical data including the results of USG and CT were collected and analyzed. Results: Sensitivity, specificity, positive and negative predictive values of USG were 98.7%, 96.8%, 98.1%, 97.8% in non-perforation group and 90.8%, 100%, 100%, 81.9% in perforation group. Those of CT were 96.4%, 100%, 100%, 96.5% and 86.6%, 100%, 100%, 87.5% respectively. Those of follow-up CT after USG were 100%, 100%, 100%, 100% and 87.5%, 100%, 100%, 92.0% respectively. The duration of using antibiotics in seven patients showed positive correlation with the interval between two imaging studies (r=0.0472, p=0.019). There was no statistical significance of correlation when these imaging studies performed within 30 hours together. Conclusion: In most of the cases, single choice between USG and CT would be enough to diagnose the acute appendicitis in children. But, it may be helpful to perform CT as early as possible subsequently to USG when there is discrepancy between initial USG and clinical impression.

  • PDF