A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

Study on Fabrication and Photoluminescent Properties of Fine Phosphor Film for Application of Radiation Image Sensor (방사선 영상센서 적용을 위한 미세 발광체 필름 제조 및 광학적 특성에 관한 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Kwang-Oop;Moon, Yong-Soo;Kim, Mi-Young;Lee, Sang-Bong;Jung, Bong-Jae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.25-28
    • /
    • 2010
  • In this paper, the fabrication and feasibility study of clinical application with euripium doped gadollium oxide ($Gd_2O_3$:Eu) nano phosphor derived by low-temperature solution combustion method. From the fabricated phosphor, the photoluminescent characteristic and linearity as a function of phosphor film thickness were investigated to evaluate x-ray converstion properties. From the experimental results, the luminescent intensity was $2945pC/cm^2$-mR at $270{\mu}m$ $Gd_2O_3$:Eu film and this value is higher 1.2 time the conventional bulk phosphor, which is possible to imaging acquisition. And good linearity was shown at x-ray exposure range for clinical diagnostic application.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System (화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구)

  • Yun Ju-Young;Seong Dae-Jin;Shin Yong-Hyoen;Lee Ji-Hun;Moon Doo-Kyung;Kang Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • In examining particulate deposits in the pipes of a chemical vapor deposition (CVD) system, vibration diagnostics is compared and studied against ultrasonic diagnostics, The latter method involves pulsing the outer wall of pipes with an ultrasonic sensor and analyzing the resulting echo to observe particulate deposits inside pipes. Vibration diagnostics examines the existence of particulate deposits by analyzing the difference in the frequencies generated when a vibrator is adhered to the outer wall of pipes. With ultrasonic diagnostics, good test results were obtained only when particulate deposits were attached to the inner wall of the pipes, After some time, however, particulate deposits were not detected properly, as the ultrasonic wave failed to cross the fine gaps created between the inner wall of the pipe and the deposits. The ultrasonic wave bounced back because of the dried particulate deposits on the wall. Thus, it has been proven that the ultrasonic diagnostics is not an appropriate means of examining the particulate deposits in a vacuum, On the other hand, vibration diagnostics succeeded in detecting the particulate deposits regardless of the lapsed time. In conclusion, the vibration diagnostics is being expected as the effective method in monitoring the particulate deposits inside pipes in the CVD system where the desired behavior is reduced frequency along with the particulate deposits in comparison to the case where the pipe is clean.

Proximal caries detection using digital subtraction radiography in the artificial caries activity model (인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Young-Ho;Kim, Kyung-Sook;Jin, Hyun-Seok;Hong, Kyung-Won;Oh, Berm-Seok;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Research on Communication and The Operating of Server System for Vehicle Diagnosis and Monitoring (차량진단 및 모니터링을 위한 통신과 서버시스템 운용에 관한 연구)

  • Ryoo, Hee-Soo;Won, Yong-Gwan;Park, Kwon-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.6
    • /
    • pp.41-50
    • /
    • 2011
  • This article is concerned with the technology to provide car driver the car's status which are composed of car trouble code in car engine and many sensors. In addition, it installs vehicle diagnostic programs on wireless communication's portable device, for example, Smart phone, PDA, PMP, UMPC. As a result, this is to provide car manager with many information of car sensors when we go to car maintenance. it can monitor relevant information on vehicle by portable device in real time, alert drivers with specific messages and also enable them to address abnormalities immediately. Moreover, the technology could help the drivers who perhaps don't know very well about their vehicles to drive safely and economically as well; the reason is because the whole system is composed of just Vehicle-information collecting device and personal wireless communication's portables and transfers the relating data to server computers through wireless network in order to handle information on vehicles. This technology make us monitor vehicle's running, failure and disorder by using wireless communication's portable device. Finally, this study system is composed of a lot of application to display us the car's status which get car's inner sensor information while driving a car.

Development of Extracting Solution for Soil Chemical Analysis Suitable to Integrated Ion-selective Micro-electrodes (집적형 이온선택성 미세전극 센서에 적합한 토양화학 분석용 침출액 종 개발)

  • Shin, Kook-Sik;Lim, Woo-Jin;Lee, Sang Eun;Lee, Jae Seon;Cha, Geun Sig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.513-521
    • /
    • 2009
  • The primary goal of this research was to develop an optimized analytical procedure for soil analysis based on ion-selective microelectrodes for agricultural purposes, which can perform on-site measurement of various ions in soil easily and rapidly. For the simple and rapid on-site diagnosis, an analysis of soil chemicals was performed employing a multicomponent-in-situ-extractant and an evaluation of ionselective microelectrodes were conducted through the regressive correlation method with a standard analytical approach widely employed in this area. Examination of sensor responses between various soil nutrient extractants revealed that 0.01M HCl and 1M LiCl provided the most ideal Nernstian response. However, 1M LiCl deteriorated the selective response for analytes due to high concentration (1M) of lithium cation. Thus, employing either 0.1M HCl as an extractant followed by 10 times dilution, or 0.01M HCl as an extractant without further dilution was chosen as the optimal extractant composition. A study of regressive correlation between results from ion-selective microelectrodes and those from the standard analytical procedure showed that analyses of $K^+$, $Na^+$, $Ca^{2+}$, and $NO_3{^-}$ showed the excellent consistency between two methods. However, the response for $NH_4{^+}$ suffered the severe interference from $K^+$. In addition, the selectivity for $Mg^{2+}$ over $Ca^{2+}$ was not sufficient enough since available ionophores developed so far do not provide such a high selectivity for $Mg^{2+}$. Therefore, as an agricultural on-site diagnostic instrument, the device in development requires further research on $NH_4{^+}$ analysis in the soil sample, development of $Mg^{2+}$-selective ionophore, and more detailed study focused on potassium, one of the most important plant nutrients.