• 제목/요약/키워드: Diagnostic reference levels

검색결과 47건 처리시간 0.023초

Double-Chambered Right Ventricle in an Old Standard Poodle Dog

  • Yunho Jeong;Yoonhwan Kim;Eunchan Lee;Ju-Hyun An;Sooyoung Choi;Jin-Young Chung;Jin-Ok Ahn
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.130-134
    • /
    • 2023
  • A 12-year-old Standard Poodle presented with intermittent weakness and occasional dyspnea at the Veterinary Medicine Teaching Hospital of Kangwon National University. A grade of 4 out of 6 systolic murmur with an irregular tachycardic rhythm was auscultated on both sides of the chest. Systolic blood pressure was 140 mmHg. Panting was noticed in the hospital, but there was no crackle sound. Blood analysis revealed mild increases in liver panel levels (alanine aminotransferase 149 [reference interval, 19-70] U/L; and alkaline phosphatase, 185 [reference interval, 15-127] U/L) and severe increases in cardiac biomarker levels (n-terminal pro-brain natriuretic peptide, 4169 [reference interval, 50-900] pmol/L; and cardiac troponin I, 0.22 [reference interval, 0.03-0.12] ng/mL). On electrocardiography, irregularly irregular supraventricular tachycardic rhythm with an f-wave and no distinct p-wave was observed. Generalized cardiomegaly with an enlarged right atrium and left ventricle was confirmed on thoracic radiography. Moreover, hepatomegaly and an enlarged caudal vena cava were observed. Echocardiographic evaluation revealed a fibromuscular diaphragm in the right ventricle. Because of the obstructive lesion in the right ventricle, the right atrium and ventricle were enlarged (right atrial area index, 38.82 cm2/m2 [reference interval, 4.2-10.2 cm2/m2]; right ventricle end-diastolic area index, 14.152 cm2/m2 [reference interval, 4.9-10.92 cm2/m2]). Accordingly, the patient was diagnosed with double-chambered right ventricle (DCRV). Pimobendan, furosemide, enalapril, diltiazem, and S-adenosylmethionine (SAMe) were prescribed, and all symptoms were relieved. DCRV is a right-sided congenital heart defect resembling pulmonic valve stenosis. If symptoms are not severe, medical therapy can be facilitated without surgery or the balloon dilation.

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • 제42권4호
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

우리나라의 골반 및 요추 엑스선검사에서의 환자선량 권고량 (Diagnostic Reference Levels for Patient Radiation Doses in Pelvis and Lumbar spine Radiography in Korea)

  • 이광용;이병영;이정은;이현구;정승환;김병우;김혁주;김동섭
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.401-410
    • /
    • 2009
  • 목 적 : 골반 및 요추 엑스선검사는 진단 엑스선검사 중 생식선을 포함하고 있고 환자가 받는 방사선량이 많은 검사로서 우리나라에는 골반 및 요추 엑스선검사에서의 환자선량 권고량이 마련되어 있지 않다. 따라서 국내 의료기관에서의 골반 및 요추 엑스선검사 시 환자가 받는 방사선량을 측정 평가하고 골반 및 요추 엑스선검사에서 환자의 방사선 방어 최적화를 위한 환자선량 권고량을 확립한다. 방 법 : 전국 125개 의료기관에서 골반 전후면 촬영, 요추 전후면 및 측면 촬영시 촬영조건과 진단영상정보를 조사 분석하고 환자가 받는 입사표면선량을 유리선량계를 사용하여 측정 평가한다. 환자가 받는 방사선량 중 제3사분위값에 해당하는 선량값을 의료기관에 권고할 골반 및 요추 엑스선검사에서의 환자선량 권고량으로 확립한다. 결 과 : 전국 125개 의료기관에서 골반 및 요추 엑스선검사 시 진단영상정보를 조사하고 환자가 받는 입사 표면선량을 측정한 결과 골반 전후면 엑스선검사에서는 관전압이 60~97 kVp, 평균 75 kVp를 사용하였고, 관전류-시간곱(mAs)는 8~123 mAs, 평균 29.7 mAs를 사용하였다. 요추 전후면 및 측면 엑스선검사에서는 관전압을 각각 65~100 kVp, 평균 78 kVp와 70~109 kVp, 평균 87 kVp를 사용하였고, mAs도 각각 10~100 mAs, 평균 35.2 mAs와 8.9~300 mAs, 평균 64.1 mAs를 사용하였다. 골반 및 요추 엑스선검사에서의 환자가 받는 입사표면선량을 측정한 결과, 골반 전후면 엑스선검사에서는 최소값 0.59 mGy, 최대값 12.69 mGy, 평균값 2.88mGy이었으며, 제1사분위값은 1.91 mGy, 중앙값은 2.67 mGy, 제3사분위값은 3.42 mGy이었다. 요추 전후면 엑스선검사에서는 최소값 0.64 mGy, 최대값 23.84 mGy, 평균값 3.68 mGy이었으며, 제1사분위값은 2.41 mGy, 중앙값은 3.40 mGy, 제3사분위값은 4.08 mGy이었다. 요추 측면 엑스선검사에서는 최소값 1.90 mGy, 최대값 45.42 mGy, 평균값 10.08 mGy이었으며, 제1사분위값은 6.03 mGy, 중앙값은 9.09 mGy, 제3사분위값은 12.65 mGy이었다. 결 론 : 우리나라의 의료기관에서 골반 전후면 엑스선검사에서 의료기관에 권고할 환자선량 권고량은 3.42 mGy, 요추 전후면 엑스선검사에서는 4.08 mGy, 요추 측면촬영에서는 12.65 mGy로 세계보건기구 등 6개 국제기구가 공동으로 권고한 골반 전후면 검사 10 mGy, 요추 전후면 검사 10 mGy 및 요추 측면 검사 30 mGy 보다는 낮았다.

  • PDF

소아 두부 전산화단층촬영 선량지표 분석을 통한 피폭선량 모니터링: 일개병원 사례 중심으로 (Analyzed the Computed Tomography Dose Index (CTDI) to the Pediatric Brain CT by Reason of the Observation for the Exposure Dose: Base on a Hospital)

  • 이재승;김현진;임인철
    • 한국콘텐츠학회논문지
    • /
    • 제15권6호
    • /
    • pp.290-296
    • /
    • 2015
  • 본 연구는 일개병원에서 시행된 년간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고 준위와 비교하여 분석함으로써 제안점을 도출하고 피폭 방사선량 저감화 방안을 제시하고자 하였다. 이를 위하여 2014년 1월부터 12월까지 두부 손상으로 소아 두부 CT 검사를 의뢰 받은 10세 미만의 소아 231명을 후향적으로 조사하였다. 조사 방법은 선량 보고서와 의료전자차트를 참조하여 일반적 특성, 관전압(kVp), 관전류(mA), 검사 범위, $CTDI_{vol}$, DLP를 조사하여 분석하였다. 결과적으로 $CTDI_{vol}$은 전체 연구대상자의 7.4%(17명)가 국내 진단참고준위를 초과한 것으로 나타났으며 DLP의 경우 41.6%(96명)가 초과 되어 $CTDI_{vol}$ 보다 비교적 높게 나타났다. DLP는 한국식품의약품안전처에서 제시한 CT 선량 지표보다 대부분 약 60% 이상 초과되었으며 건강보험심사평가원에서 제시한 기준 검사 범위보다 약 30%이상 증가된 검사 범위가 DLP가 높게 나타난 원인으로 분석되었다. 결론적으로 임상에서 CT 검사 시 건강보험심사 평가원에서 제시하는 소아 두부 CT 검사의 기준 검사 범위를 준수하여 검사하고 프로토콜을 적절히 조절한다면 피폭선량을 상당히 낮출 수 있을 것으로 판단된다.

Establishment of Local Diagnostic Reference Levels of Pediatric Abdominopelvic and Chest CT Examinations Based on the Body Weight and Size in Korea

  • Jae-Yeon Hwang;Young Hun Choi;Hee Mang Yoon;Young Jin Ryu;Hyun Joo Shin;Hyun Gi Kim;So Mi Lee;Sun Kyung You;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • 제22권7호
    • /
    • pp.1172-1184
    • /
    • 2021
  • Objective: The purposes of this study were to analyze the radiation doses for pediatric abdominopelvic and chest CT examinations from university hospitals in Korea and to establish the local diagnostic reference levels (DRLs) based on the body weight and size. Materials and Methods: At seven university hospitals in Korea, 2494 CT examinations of patients aged 15 years or younger (1625 abdominopelvic and 869 chest CT examinations) between January and December 2017 were analyzed in this study. CT scans were transferred to commercial automated dose management software for the analysis after being de-identified. DRLs were calculated after grouping the patients according to the body weight and effective diameter. DRLs were set at the 75th percentile of the distribution of each institution's typical values. Results: For body weights of 5, 15, 30, 50, and 80 kg, DRLs (volume CT dose index [CTDIvol]) were 1.4, 2.2, 2.7, 4.0, and 4.7 mGy, respectively, for abdominopelvic CT and 1.2, 1.5, 2.3, 3.7, and 5.8 mGy, respectively, for chest CT. For effective diameters of < 13 cm, 14-16 cm, 17-20 cm, 21-24 cm, and > 24 cm, DRLs (size-specific dose estimates [SSDE]) were 4.1, 5.0, 5.7, 7.1, and 7.2 mGy, respectively, for abdominopelvic CT and 2.8, 4.6, 4.3, 5.3, and 7.5 mGy, respectively, for chest CT. SSDE was greater than CTDIvol in all age groups. Overall, the local DRL was lower than DRLs in previously conducted dose surveys and other countries. Conclusion: Our study set local DRLs in pediatric abdominopelvic and chest CT examinations for the body weight and size. Further research involving more facilities and CT examinations is required to develop national DRLs and update the current DRLs.

디지털공제프로그램간의 디지털공제영상 비교 (A comparison of subtracted images from dental subtraction programs)

  • 한원정
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Extremely Increased Serum Carbohydrate Antigen 19-9 Levels Caused by New or Resistant Infections to Previous Antibiotics in Chronic Lung Diseases

  • Shin, Ji Young;Yoo, Su Jin;Park, Bo Mi;Jung, Sung Su;Kim, Ju Ock;Lee, Jeong Eun
    • Tuberculosis and Respiratory Diseases
    • /
    • 제75권3호
    • /
    • pp.125-127
    • /
    • 2013
  • In this paper, we describe 72-year-old female patient without evidence of malignant disease presented with significantly elevated serum carbohydrate antigen (CA) 19-9 levels by respiratory infections. She was diagnosed with respiratory infections due to Mycobacterium avium complex and Pseudomonas aeruginosa. The serum CA 19-9 levels remarkably increased (1,453-5,300 U/mL; reference range, <37 U/mL) by respiratory infection and abruptly decreased (357-534 U/mL) whenever infection was controlled by specific treatments. This case suggests that serum CA 19-9 levels may be used as a diagnostic marker to indicate new or resistant infections to previous antibiotics in chronic lung diseases without significant changes in chest X-ray findings.

MicroRNAs and periodontal disease: a qualitative systematic review of human studies

  • Mico-Martinez, Pablo;Alminana-Pastor, Pedro J.;Alpiste-Illueca, Francisco;Lopez-Roldan, Andres
    • Journal of Periodontal and Implant Science
    • /
    • 제51권6호
    • /
    • pp.386-397
    • /
    • 2021
  • Purpose: MicroRNAs (miRNAs) are epigenetic post-transcriptional regulators that modulate gene expression and have been identified as biomarkers for several diseases, including cancer. This study aimed to systematically review the relationship between miRNAs and periodontal disease in humans, and to evaluate the potential of miRNAs as diagnostic and prognostic biomarkers of disease. Methods: The review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines (reference number CRD42020180683). The MEDLINE, Scopus, Cochrane Library, Embase, Web of Science, and SciELO databases were searched for clinical studies conducted in humans investigating periodontal diseases and miRNAs. Expression levels of miRNAs across the different groups were analysed using the collected data. Results: A total of 1,299 references were identified in the initial literature search, and 23 articles were finally included in the review. The study designs were heterogeneous, which prevented a meta-analysis of the data. Most of the studies compared miRNA expression levels between patients with periodontitis and healthy controls. The most widely researched miRNA in periodontal diseases was miR-146a. Most studies reported higher expression levels of miR-146a in patients with periodontitis than in healthy controls. In addition, many studies also focused on identifying target genes of the differentially expressed miRNAs that were significantly related to periodontal inflammation. Conclusions: The results of the studies that we analysed are promising, but diagnostic tests are needed to confirm the use of miRNAs as biomarkers to monitor and aid in the early diagnosis of periodontitis in clinical practice.

Human Epididymis Protein 4 Reference Intervals in a Multiethnic Asian Women Population

  • Mokhtar, N.M.;Thevarajah, M.;M.A., Noorazmi;M., Isahak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권12호
    • /
    • pp.6391-6395
    • /
    • 2012
  • Background: Ovarian cancer is ranked as the fifth most common cause of cancer death in women. In Malaysia, it is the fourth most common cancer in females. CA125 has been the tumor marker of choice in ovarian cancer but its diagnostic specificity in early stages is only 50%. Hence, there is a critical need to identify an alternative tumor marker that is capable of detecting detect ovarian cancer at an early stage. HE4 is a new tumor marker proposed for the early diagnosis of ovarian cancer and disease recurrence. Currently, none of the normal ranges of HE4 quoted in the literature are based on data for a multiethnic Asian population. Therefore, the aim of this study was to determine reference intervals for HE4 in an Asian population presenting in University Malaya Medical Centre, a tertiary reference hospital. Materials and Methods: 300 healthy women were recruited comprising 150 premenopausal and 150 postmenopausal women, aged from 20-76 years. All women were subjected to a pelvic ultrasonograph and were confirmed to be free from ovarian pathology on recruitment. Serum HE4 levels were determined by chemiluminescent microparticle immunoassay (CMIA, Abbott Architect). The reference intervals were determined following CLSI guidelines (C28-A2) using a non-parametric method. Results: The upper limits of the $95^{th}$ percentile reference interval (90%CI) for all the women collectively were 64.6 pmol/L, and 58.4 pmol/L for premenopausal) and 69.0 pmol/L for postmenopausal. The concentration of HE4 was noted to increase with age especially in women who were more than 50 years old. We also noted that our proposed reference limit was lower compared to the level given by manufacturer Abbott Architect HE4 kit insert (58.4 vs 70 pmol/L for premenopausal group and 69.0 vs 140 pmol/L in the postmenopausal group). The study also showed a significant difference in HE4 concentrations between ethnic groups (Malays and Indians). The levels of HE4 in Indians appeared higher than in Malays (p<0.05), while no significant differences were noted between the Malays and Chinese ethnic groups. Conclusions: More data are needed to establish a reference interval that will better represent the multiethnic Malaysian population. Probably a larger sampling size of equal representation of the Malay, Chinese, Indians as well as the other native ethnic communities will give us a greater confidence on whether genetics plays a role in reference interval determination.

소아 두부 컴퓨터단층촬영검사에서 선량지표 분석을 통한 방사선 피폭선량 감소 방안에 대한 연구 (A Survey on the Radiation Exposure Doses Reduction Plan through Dose Index Analysis in the Pediatric Brain Computed Tomography)

  • 김현진;이효영;임인철;유윤식
    • 한국방사선학회논문지
    • /
    • 제10권3호
    • /
    • pp.161-169
    • /
    • 2016
  • 본 연구에서는 소아 두부 CT 검사에 있어서 피폭 방사선량을 경감할 수 있는 방법을 모색하고자 부산지역 병원들에서 시행된 년 간 소아 두부 CT 검사에 대한 CT 선량지표(CTDI)를 국내 진단참고준위와 비교하여 분석함으로써 제안점을 도출하고자 하였다. 결과적으로 병원별 분류에서는 병원, 종합병원, 상급종합병원 순으로 권고량이 초과하는 것으로 나타났으며 연령별 분류에서는 2-5세 이하, 1개월-1세 이하, 6-10세 이하 순으로 권고량이 초과하는 것으로 나타났다. 스캔방식별 분류에서는 Helical, Axial, Volume방식 순으로 권고량이 초과하고 있었으며 스캔범위를 진단참고준위에 맞게 재설정한 결과 상급종합병원에서 재설정으로 인한 감소율은 11.68%, 종합병원에서 15.79%, 병원에서 20.66%로 초과율이 높게 나타났다. 그리고 환자선량 권고량 가이드라인을 벗어나지 않는 환자의 평균 스캔범위의 분석결과 1개월-1세 이하에서 $103.2{\pm}11.8mm$, 2-5세 이하에서 $110.5{\pm}14.5mm$, 6-10세 이하에서는 $117.8{\pm}17.2mm$로 나타났다.