• Title/Summary/Keyword: Diagnostic imaging

Search Result 1,942, Processing Time 0.157 seconds

Signal Change of Iodinated Contrast Agents in MR Imaging (요오드화 조영제가 MR영상에 미치는 신호 변화)

  • Jeong, HK;Kim, Seongho;Kang, Chunghwan;Lee, Suho;Yi, Yun;Kim, Mingi;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.131-138
    • /
    • 2016
  • In this study, we tried to analyze the influence of ICM(Iodinated Contrast Media) in MR imaging compare to GBCA(Gadolinium Based Contrast Agent), and as this result we discussed whether resonable or not the protocol which is MRI scan after enhanced CT scan without proper time interval in clinical field. For this research, we assembled two phantoms. which one was iodine and another one was gadolinium. We did test two phantoms in conventional MRI scan which is T1, T2, T2 FLAIR and 3D angio. After that, quantitative analysis was progressed. The results of study were as follow : SSI(Saline's Signal Intensity) was shown as each sequences 175, 1231, 333, 37 [a.u] at iodine. and 1297, 123, 757, 232 [a.u] was recorded at gadolinium. BDEPS(the Biggest Difference of EPS) was shown as each sequences 1297, 123, 757, 232 [a.u] at iodine and 793, 6, 1495, 365 [a.u] was recorded at gadolinium. At this time, EPS(Enhancement Percentage to Saline) was shown 641.1, -90.0, 127.3, 527% at iodine and 685.1, 99.4, 365.7, 1077.4% was recorded at gadolinium. BP(BDEPS's point) was shown 900, 900, 477, 900 mmol at iodine and 4, 0.2, 0.2, 40 mmol was recorded at gadolinium. CPSS(Change Point of SI to SSI) was shown 63, 423, 63, 29 mmol at iodine and each [50, 30], [4, 0.2], [4, 1], 0.2 mmol was recorded at gadolinium. According to this research, we could not only discover the fact that was iodine could effect on MR signal, but also the pattern is different as various sequences compare to gadolinium. Therefore, we expect useful diagnostic MR image in clinical field with this quantitative data for deciding protocol regarding MRI and CT scan order.

In Vivo and In Vitro Studies of the Steady State Free Precession-Diffusion-Weighted MR Imagings on Low b-value : Validation and Application to Bone Marrow Pathology

  • Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Purpose : The purpose of this study was a phantom study to measure the diffusion properties of water molecules by steady-state free precession diffusion-weighted imaging (SSFP- DWI) with a low b-value and to determine if this sequence might be useful for application to the evaluation of bone marrow pathology. Materials and methods : 1. The phantom study: A phantom study using two diffusion weighted sequences for the evaluation of the diffusion coefficient was performed. Three water-containing cylinders at different temperatures were designed: phantom A was $3^{\circ}C$, B was $23^{\circ}C$ and C was $63^{\circ}C$. Both SSFP and echo planar imaging (EPI) sequences (b-value: $1000s/mm^2$) were performed for comparison of the diffusion properties. The Signal to noise ratios (SNR) and apparent diffusion coefficient (ADC) values of the three phantoms using each diffusion-weighted sequence were assessed. 2. The Clinical study: SSFP-DWI was performed in 28 patients [sacral insufficiency fractures (10), osteoporotic lumbar compression fractures (10), malignant compression fractures (8)]. To measure the ADC maps, a diffusion-weighted single shot stimulated echo-acquisition mode sequence ($650s/mm^2$) was obtained using the same 1.5-T MR imager Results : For the phantom study, the signal intensity on the SSFP as well as the classic EPI-based DWI was decreased as the temperature increased in phantom A to C. The ADC values of the phantoms on EPI-DWI were $0.13{\times}10^{-3}mm^2/s$ in phantom A, $0.22{\times}10^{-3}mm^2/s$ in B and $0.37{\times}10^{-3}mm^2/s$. in C. The SSFP can be regarded as a DWI sequence in view of the series of signal decreases. Conclusion : Bone marrow pathologies with different diffusion coefficients were evaluated by SSFP-DWI. All benign fractures were hypointense compared to the adjacent normal bone marrow where as the malignant fractures were hyperintense compared to the adjacent normal bone marrow.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Nuclear Medicine Methods of Rejection Diagnosis in Transplanted Rat Model (심장 이식된 백서에서의 거부반응 진단의 핵의학적 방법)

  • Chung, Won-Sang;Kim, Sang-Heon;Kim, Hyuck;Kim, Young-Hak;Kang, Jung-Ho;Choi, Yun-Young;Lee, Chul-Beom
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.379-383
    • /
    • 2003
  • Background: An accurate diagnosis of the severity of the rejection after a heart transplantation relies on endomyo-cardial biopsy, but because of its invasiveness and the need for repeated examination makes it is an inappropriate monitoring method. Therefore, we have tried to find a monitoring method that is continuous and less invasive. Material and Method: Heterotopic heart transplantation using Ono-Lindsey Method was done in 20 rats, and then $^{99m}$ Tc-Pyrophosphate (PYP) scan was done after a month, Uptake ratio of transplanted heart to vertebrae (H/V) was obtained to be compared with the biopsy result. Result: Rejection was defined when the H/V uptake ratio was higher than 0.09, and we compared the uptake ratio with the results of biopsy. The result was true positives was 3, true negatives 12, false negatives 2, andfalse positives 3. Therefore sensitivity was 60% and specificity was 80%, diagnostic value was 75%. Conclusion: $^{99m}$Tc-Pyrophosphate (PYP) scan was a useful method for the evaluation of the heart transplantation rejection and it will be helpful for monitoring rejection as an non-invasive and simple method.hod.

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

A Clinical Usefulness of Office Hysteroscopy (Office Hysteroscopy의 임상적 유용성)

  • Koh, Min-Whan;Lee, Tae-Hyung;Kim, Jeong-Suk;Choi, Yoon-Young;Jeong, Sang-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.81-89
    • /
    • 2005
  • Background: Hysteroscopy is considered to be the gold standard not only for visualizing the cervical canal and the uterine cavity, but also for treating many different types of benign pathologies localized to those regions. The advent and evolution of endoscopic imaging and surgery during the last two decades has added new dimensions to the armamentarium of a gynecologist to combat intrauterine lesions. Office hysteroscopy is increasingly being used as a first line investigation for abnormal uterine bleeding and other diseases involving the uterine cavity. The aim of our study is to assess the diagnostic and operative efficacy of office hysteroscopy. Materials and Methods: In our department, 140 patients underwent a hysteroscopy examination and 18 of these underwent an office based hysteroscopy examination from September 1995 to March 2005. The cases who underwent an office based hysteroscopy examination were reviewed in order to assess the clinical usefulness and significance in the management of intrauterine lesions. Results: Major indication was abnormal uterine bleeding(12 cases, 66.7%). The others were a missed IUD and infertility. The hysteroscopic findings were a normal uterine cavity(6 cases, 33.3%), IUD in situ, polyp, submucosal myoma, endometrial hyperplasia and a placenta remnant. Conclusion: Office hysteroscopy is a safe, quick and effective method for making an intrauterine evaluation. In addition, it provides immediate results, offers the capacity of direct targeted biopsies of suspicious focal lesions, and offers the direct treatment of some intrauterine conditions.

  • PDF

Application of Texture Feature Analysis Algorithm used the Statistical Characteristics in the Computed Tomography (CT): A base on the Hepatocellular Carcinoma (HCC) (전산화단층촬영 영상에서 통계적 특징을 이용한 질감특징분석 알고리즘의 적용: 간세포암 중심으로)

  • Yoo, Jueun;Jun, Taesung;Kwon, Jina;Jeong, Juyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • In this study, texture feature analysis (TFA) algorithm to automatic recognition of liver disease suggests by utilizing computed tomography (CT), by applying the algorithm computer-aided diagnosis (CAD) of hepatocellular carcinoma (HCC) design. Proposed the performance of each algorithm was to comparison and evaluation. In the HCC image, set up region of analysis (ROA, window size was $40{\times}40$ pixels) and by calculating the figures for TFA algorithm of the six parameters (average gray level, average contrast, measure of smoothness, skewness, measure of uniformity, entropy) HCC recognition rate were calculated. As a result, TFA was found to be significant as a measure of HCC recognition rate. Measure of uniformity was the most recognition. Average contrast, measure of smoothness, and skewness were relatively high, and average gray level, entropy showed a relatively low recognition rate of the parameters. In this regard, showed high recognition algorithms (a maximum of 97.14%, a minimum of 82.86%) use the determining HCC imaging lesions and assist early diagnosis of clinic. If this use to therapy, the diagnostic efficiency of clinical early diagnosis better than before. Later, after add the effective and quantitative analysis, criteria research for generalized of disease recognition is needed to be considered.