• 제목/요약/키워드: Diagnostic error

검색결과 218건 처리시간 0.026초

US-guided 14G Core Needle Biopsy: Comparison Between Underestimated and Correctly Diagnosed Breast Cancers

  • Kim, Hana;Youk, Ji Hyun;Kim, Jeong-Ah;Gweon, Hye Mi;Jung, Woo-Hee;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.3179-3183
    • /
    • 2014
  • Background: The purpose of study was to evaluate radiologic or clinical features of breast cancer undergoing ultrasound (US)-guided 14G core needle biopsy (CNB) and analyze the differences between underestimated and accurately diagnosed groups. Materials and Methods: Of 1,898 cases of US-guided 14G CNB in our institute, 233 cases were proven to be cancer by surgical pathology. The pathologic results from CNB were invasive ductal carcinoma (IDC) (n=157), ductal carcinoma in situ (DCIS) (n=40), high-risk lesions in 22 cases, and benign in 14 cases. Among high-risk lesions, 7 cases of atypical ductal hyperplasia (ADH) were reported as cancer and 11 cases of DCIS were proven IDC in surgical pathology. Some 29 DCIS cases and 157 cases of IDC were correctly diagnosed with CNB. The clinical and imaging features between underestimated and accurately diagnosed breast cancers were compared. Results: Of 233 cancer cases, underestimation occurred in 18 lesions (7.7%). Among underestimated cancers, CNB proven ADH (n=2) and DCIS (n=11) were diagnosed as IDC and CNB proven ADH (n=5) were diagnosed at DCIS finally. Among the 186 accurately diagnosed group, the CNB results were IDC (n=157) and DCIS (n=29). Comparison of underestimated and accurately diagnosed groups for BI-RADS category, margin of mass on mammography and US and orientation of lesion on US revealed statistically significant differences. Conclusions: Underestimation of US-guided 14G CNB occurred in 7.7% of breast cancers. Between underestimated and correctly diagnosed groups, BI-RADS category, margin of the mass on mammography and margin and orientation of the lesions on US were different.

진단용 X선 발생 장치의 X선 출력에 관한 연구 (A Study of X-ray Output for Diagnostic X-ray Equipment)

  • 고신관;안봉선;장상섭;최종운;신영순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권2호
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

진단용 엑스선 장치의 안전관리 검사에 관한 연구 (A Study on Safety Management Inspection of Diagnostic X-ray System)

  • 이후민;김현주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.887-893
    • /
    • 2018
  • 본 연구는 병원 및 대학교 등에 설치된 X선 발생장치를 대상으로 진단용 방사선 발생장치의 품질관리 항목을 적용하여 성능 비교를 하여 주기적인 성능관리의 중요성을 인식시켜 성능유지 및 관리에 도움을 주고자 한다. 우선 재현성 및 직선성 실험결과 모든 실험조건에서 합격기준에 부합되었으며 주기적인 정도관리가 부족한 GX-650장치의 경우 재현성 평가의 백분율 오차가 높았으며 직선성 평가에서는 관전압을 100 kVp로 설정 시 0.105로 백분율 오차에서 벗어나게 측정되었다. 또한 관전압 및 관전류의 정확도 평가결과 상대적으로 X선 발생횟수가 낮은 장치에서 백분율 오차가 낮은 것을 알 수 있었다. 반가층 실험은 모든 장치에서 관전압 별 반가층 기준에 모두 포함되었다. 따라서 병원용, 실습용 구분보다는 모든 장치의 정도관리의 중요성을 인식하고 적극적으로 장치의 성능관리를 시행하여 장치를 유지 관리해야 할 것이며 특수의료장비처럼 짧은 주기의 정도관리 제도를 마련해야 할 것으로 사료된다.

육안검사기술의 실무적 이해 (Practical Understanding of Gross Examination Techniques)

  • 지우현
    • 대한임상검사과학회지
    • /
    • 제56권1호
    • /
    • pp.89-98
    • /
    • 2024
  • 육안검사는 정확한 병리조직학적 진단을 위해 수술, 내시경 검사에서 채취된 검체를 육안검사를 통해 암의 육안정보를 기록하고 병변은 현미경 표본을 만들기 위해 절편을 채취하는 행위이다. 육안검사의 기술은 간결하고 정확한 표현, 적절한 구조화, 충분한 절제, 중요정보에 대한 오류가 없는 표준화, 복잡한 검체의 사진 도표화가 이루어져야 한다. 병리학적 판독의 만족도를 높이기 위해서는 육안검사에 대한 이해가 충분한 이론적 실무적 바탕에서 신뢰를 얻기 위한 정확하고 신중히 수행해야 하는 업무이다. 육안검사 분야에서 임상병리사들의 경험을 바탕으로, 추가 표본 유형이 실행 가능한 후보로 식별되고 치료 측면에서 요구와 우려 사항을 신중하게 고려해야 한다. 또한, 각 기관의 부서에서는 임상과의 파트너쉽, 지속적인 전문인력 양성, 진단오류 및 가치 기반의 의료제공에 대한 국가적 초점 측면에서 검토해야 할 것이다.

유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석 (Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients)

  • 이레나
    • Radiation Oncology Journal
    • /
    • 제23권3호
    • /
    • pp.169-175
    • /
    • 2005
  • 목적: 방사선 치료 시 3차원 영상 획득에 방사선치료 전용으로 개발된 모의 CT를 사용하고 있으나 아직까지도 많은 병원에서는 일반 진단용 CT를 이용하고 있다. 따라서 본 연구에서는 21명의 유방암 환자를 대상으로 모의치료, 진단용 CT기를 이용한 CT 스캔, 및 치료 과정 사이의 준비 오차를 분석하였다. 대상 및 방법: 준비 오차는 isocenter, SSD, CLD, 및 수술 시 삽입된 클립의 위치들의 변화를 계산하여 분석하였다. 모의조사에서 얻어진 x-ray 영상에 나타난 해부학적 구조물과 CT 스캔 시 isocenter를 표시하기 위해 환자의 몸에 부착된 marker를 기준으로 정해진 isocenter에서 얻은 DRR 영상상의 구조물을 비교하여 잘 일치하지 않을 경우 새로운 isocenter가 정해졌고 이러한 isocenter의 위치 변화를 계산하였다. 결과: 21명의 환자 중 7명의 경우 DRR상과 모의치료 필름상의 해부학적 구조물이 21명의 환자 중 7명이 일치하지 않았으므로 치료계획을 실행하기에 앞서 새로운 isocenter를 정하였다. Isocenter 이동을 근거로 계산된 진단용 CT와 모의 치료간에 발생되는 평균 준비오차의 표준편차는 횡측 방향으로 2.3 mm, longitudinal 방향으로 1.6 mm, 그리고 AP 방향으로 1.6 mm이다. 모의치료와 CT data의 AP 방향 및 tangential 방향에서 측정된 SSD 값의 평균오차 및 표준편차는 각각 $1.9{\pm}2.3\;mm$$2.8{\pm}3.7\;mm$이다. 모의치료와 DRR간의 CLD 오차의 변화범위는 0에서 6 mm 이고 모의치료와 portal 영상간의 오차범위는 0에서 5 mm이다. 클립을 기준으로 계산된 그룹의 systematic error는 횡측 방향으로 1.7 mm, AP 방향으로 2.1 mm, 그리고 SI 방향으로 1.7 mm이다. 결론: 연구 결과 SSD, CLD, 클립의 움직임 및 isocenter의 위치변화 측면에서 분석될 경우 그다지 큰 오차는 발생하지 않았음을 보여준다. 그러므로 본 연구결과 유방암 환자의 경우 진단용 CT를 사용한다 하더라도 준비오차는 모의 CT를 사용하는 경우와 비교하여 차이가 없음을 알 수 있다. 그러나 모의치료와 CT스캔 사이의 준비오차를 감소하기 위해서는 CT 영상 획득 시 환자 위치고정에 특별한 주의를 기울여야 한다.

Evaluation of Cardiac Function Analysis System Using Magnetic Resonance Images

  • Tae, Ki-Sik;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo;Shinn, Kyung-Sub;Jung, Seung-Eun;Lee, Jae-Moon
    • 한국의학물리학회지:의학물리
    • /
    • 제10권3호
    • /
    • pp.159-168
    • /
    • 1999
  • Cardiac disease is one of the leading causes of death in Korea. In quantitative analysis of cardiac function and morphological information by three-dimensional reconstruction of magnetic resonance images, left ventricle provides an important role functionally and physiologically. However, existing procedures mostly rely on the extensive human interaction and are seldom evaluated on clinical applications. In this study, we developed a system which could perform automatic extraction of enpicardial and endocardial contour and analysis of cardiac function to evaluate reliability and stability of each system comparing with the result of ARGUS system offered 1.5T Siemens MRI system and manual method performed by clinicians. For various aspects, we investigated reliability of each system by compared with left ventricular contour, end-diastolic volume (EDV), end-systolic volume (ESV), stock volume (SV), ejection fraction (EF), cardiac output (CO) and wall thickness (WT). When comparing with manual method, extracted results of developed process using minimum error threshold (MET) method that automatically extracts contour from cardiac MR images and ARGUS system were demonstrated as successful rate 90% of the contour extraction. When calculating cardiac function parameters using MET and comparing with using correlation coefficients analysis method, the process extracts endocardial and epicardial contour using MET, values from automatic and ARGUS method agreed with manual values within :t 3% average error. It was successfully demonstrated that automatic method using threshold technique could provide high potential for assessing of each parameters with relatively high reliability compared with manual method. In this study, the method developed in this study could reduce processing time compared with ARGUS and manual method due to a simple threshold technique. This method is useful for diagnosis of cardiac disease, simulating physiological function and amount of blood flow of left ventricle. In addition, this method could be valuable in developing automatic systems in order to apply to other deformable image models.

  • PDF

폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성 (The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism)

  • 김우규;임병성;김미영;황홍곤
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.669-680
    • /
    • 1999
  • 연구배경: 폐색전증은 조기진단으로 신속한 치료를 요하는 치명적인 질환으로 관심여부에 따라서는 비슷한 조건의 병원규모라 하더라도 진단율이 상이한 차이를 나타내는 것으로 알려져있다. 폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술은 높은 민감도와 특이도를 나타낸다고 알려져있다. 저자들은 폐색전증에서 나선식 전산화 단층촬영 혈관조영술의 2, 3차원 영상소견과 진단적 가치를 평가하였고, 나선식 전산화 단층촬영 혈관조영술과 폐관류 스캔을 비교하였다. 방 법: 1997년 9월에서부터 1998년 8월까지 20명의 환자에서 나선식 전산화 단층촬영 혈관조영술을 시행하였고, 이 중 14명의 환자에서 폐관류 스캔을 동시에 시행하여 그 임상적 기록과 함께 분석하였다. 또한 색전의 위치에 따른 혈관 분포 및 동반된 폐실질의 변화를 분석하였다. 결 과: 폐색전증의 색전의 위치에 따른 분포양상을 보면, 좌측 혜(n=103) 보다 우측 폐(n=129)에, 좌 우측폐의 상엽과 중엽을 합친 것(n=101)보다 하엽(n=116)에 많은 빈도를 보였고, 세분절이하로 갈수록 많은 빈도를 보이는데 하엽에서는 5 번째에서 감소되는데, 이것은 세분절이하 혈관 색전에서 나선식 전산화 단층촬영 혈관조영술의 낮은 발견율 및 동반된 폐경색과 무기폐 등이 주로 하엽에 생기기 때문에 가려진 것으로 생각된다. 나선식 전산화 단층촬영 혈관조영술로 폐색전증 진단시, 1명에서 위음성을 보여 95%(19명/20명)의 발견율을 보였고, 급성 및 만성 소견이 각각 16명, 3명이었고, 폐경색, 무기폐, 흉막삼출이 각각 9명(45%), 4명(20%), 6명(30%)이었다. 결 론: 2, 3차원 영상이 포함된 나선식 전산화 단층촬영 혈관조영술은 폐색전증에서 비침습적인 진단 방법으로 1) 폐실질을 포함하여 색전의 전체적 분포를 용이하게 알 수 있으며, 2) 진단시 높은 발견율을 보이며, 3) 비교적 급성과 만성의 구분이 되고, 4) 동반된 폐실질의 변화와 흉막삼출을 보는데 유용한 진단방법이며, 5) 폐관류 스캔 소견과 높은 연관성을 보였다. 제한점으로는 세분절이하에서 인지 장애(perception error)가 있다. 또한, 만성 폐쇄성 폐질환, 천식, 결핵 등이 동반된 호흡기 질환에서는 색전이 나선식 전산화 단층촬영 혈관조영술에서 간과(missing) 될 수 있다.

  • PDF

화학적산소요구량의 총유기탄소 변환을 위한 이상자료의 탐지와 처리 (Outlier Detection and Treatment for the Conversion of Chemical Oxygen Demand to Total Organic Carbon)

  • 조범준;조홍연;김성
    • 한국해안·해양공학회논문집
    • /
    • 제26권4호
    • /
    • pp.207-216
    • /
    • 2014
  • 총유기탄소(TOC)는 해양의 탄소순환 연구분야에서 직접적인 생물학적 지표로 이용되는 중요한 인자다. 가용한 TOC 자료가 상대적으로 화학적산소요구량(COD) 자료 보다 부족하기 때문에 COD 자료를 활용하여 TOC 자료를 추정할 수 있다. COD를 TOC 로의 변환 시 TOC 추정에 직접적으로 영향을 미치는 COD 관측자료에 포함된 이상자료의 탐지와 적절한 처리는 합리적이고 객관적으로 수행되어야 한다. 본 연구에서는 국내 연안해역에서 관측된 염분, COD 및 TOC 자료에 대한 최적회귀모형을 제시하였다. 최적회귀모형은 이상자료와 영향자료를 여러 가지 탐색방법으로 진단하여 제거 전 후의 자료 개수 변화, 변동계수 및 RMS 오차를 비교 및 분석하여 선택하였다. 연구수행 결과, Cook의 진단방법과 SIQR의 boxplot 방법을 조합한 방법이 가장 적절한 것으로 파악되었다. 최적 회귀 함수는 TOC(mg/L) = $0.44{\cdot}COD(mg/L)+1.53$ 이고, 결정계수는 0.47 정도로 나타났으며, RMS 오차는 0.85 mg/L이다. RMS 오차와 지레계수(leverage values)의 변동계수는 이상자료 제거 전에 비하여 각각 31%, 80%로 크게 감소되었다. 본 연구에서 제시된 방법을 통해 COD와 TOC 관측자료에 포함된 이상자료와 영향자료의 과도한 영향을 진단 및 제거하였기 때문에 보다 적절한 회귀곡선식을 제시할 수 있었다.

디지털 방사선 시스템에서 발생하는 Artifact (Artifacts in Digital Radiography)

  • 민정환;김정민;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.375-381
    • /
    • 2015
  • 디지털 방사선 시스템은 영상의학에서 큰 비중을 차지하고 있다. 잘못된 영상이 제공 된다면 이는 환자의 건강에 나쁜 영향을 줄 수 있기에, 올바른 디지털 방사선 영상이 제공되어야만 한다. 또한, artifact는 오진으로 이어질 수 있다. 디지털 방사선 시스템에서 발생하는 artifact를 종류별로 분석하여 그 결과 분석하였다. 본 연구에서 사용된 artifact는 서울의 종합병원 급 의료기관에서 2007년부터 2014년까지 수집된 자료들이다. 수집된 자료는 발생 원인별로 구별하여 그 원인을 분석하였다. artifact는 하드웨어적 artifact, 소프트웨어적 artifact, 사용자 오류, 시스템 artifact 및 기타로 구분하였다. 하드웨어적 artifact는 Ghost가 가장 빈번하게 관찰되었으며, 이는 신호의 잔류에 의한 것이다. 다음은 RF 잡음에 의한 오류, 장비 내 이물질에 의한 오류 순이다. 소프트웨어 artifact는 많은 원인이 있다. 부정확한 영상 교정에 의한 artifact가 가장 많았으며, EDR 인식오류, 접합면 처리 오류 등이 있으며, 소프트웨어 artifact는 매우 다양한 경향을 나타낸다. 사용자 오류는 디지털 의료 영상 시스템을 바르게 이해하지 못해 발생시킨 것들이 많았다. 아울러, 시스템 artifact는 DICOM 헤더 정보 오류, 압축 오류가 있다. 분명하게 나타나는 artifact는 재촬영의 원인이 되어 환자의 피폭을 증가시키고, 불분명하게 나타나는 artifact는 오진을 유발 시킬 수 있다. 따라서 방사선사에게서 이러한 artifact를 바로 구별 할 수 있는 능력이 요구 된다. 그러므로 artifact가 발생되는 원인과 그 특성을 분명하게 이해함으로 지속적인 교육과 안정적인 시스템 운영에 힘써야 할 것으로 사료된다.

진단용 CT-모의치료기 테이블의 효율적인 교정 방법 (An Efficient Correction Process of CT-Simulator Couch with Current Diagnostic CT Scanners)

  • 구은회;이재승;조정근;문성권
    • 한국콘텐츠학회논문지
    • /
    • 제9권11호
    • /
    • pp.254-261
    • /
    • 2009
  • 본 연구는 진단용 CT 장치를 이용한 CT-모의치료기의 테이블 및 레이저 정렬 시스템과 횡단면 영상의 중심간 정렬을 개선하기 위한 효율적인 방법을 제안하고자 하였다. 본원에서 제작한 팬텀을 이용하여 AAPM TG66에서 제시하는 일일 정도관리를 시행하고 기하학적 삼각함수를 이용하여 레이저 정렬 시스템을 교정하였으며 교정 전, 후를 비교함으로서 교정방법에 대한 효율성을 검토하였다. 교정 전 영상의 중심간 오차는 3.82mm, 테이블 종축은 $0.436^{\circ}$ 틀어져 진행하였다. 기하학적 삼각함수를 이용한 레이저 정렬 시스템의 교정 후 0.7mm의 중심간 오차가 발생하여 ${\pm}2mm$의 허용오차 범위를 만족하였다. 설치 가동 중인 진단용 CT 장치를 방사선치료 전용 CT-모의치료기로 활용하는 경우 기하학적 정확도를 만족시키기 위한 테이블 교정은 기술적인 한계 뿐 만 아니라 시간 및 경제적 손실에 비하여 매우 비효율적이다. 그러나 레이저 정렬 시스템을 이용한 교정 방법은 경제적이고 비교적 간단하면서도 만족스러운 기하학적 정확도를 얻을 수 있어 임상에서 적용할 수 있는 효율적인 방법이라 사료된다.