• Title/Summary/Keyword: Diagnostic ability

Search Result 318, Processing Time 0.027 seconds

An Experimental Study for the Prevention of CT Contrast Media Extravasation with Extravasation Detection Accessory System in Femoral Vein of Rabbit (가토 정맥에서 CT 조영제의 혈관외유출 예방을 위한 EDA 시스템의 실험적 연구)

  • Kweon, Dae-Cheol;Jeong, Seok-Hee;Yang, Sung-Hwan;Cho, Mun-Son;Jang, Keun-Jo;Kim, Sun-Geun;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.238-245
    • /
    • 2006
  • To assess the ability of an extravasation defection accessory (EDA) to detect the clinically important extravascular Injection of iodinated contrast material that was delivered with an automated mechanical power injector. The purpose of this study was to assess the ability of this device during clinically important episodes of extravasation. The EDA system was composed of a strain gage, an amplifier and a computer-based system. In the rabbit experimental cases, there were seven true-positive cases (range of the extravasation volumes: $14{\sim}23 ml$). The algorithm results showed seven true-positive cases (range of the extravasation volumes: $7{\sim}16ml$), nineteen true-negative cases, two false-positive cases and no false-negative cases. The EDA system had a sensitivity of 100% and a specificity of 90% for the detection of clinically important extravasation. The EDA system had good sensitivity for the detection of clinically important extravasation and the EDA system has the clinical potential for the early detection of extravasation of the contrast medium that is administered with power injectors.

  • PDF

Inhibitory Effects of Gallic Acid Isolated from Caesalpinia mimosoides Lamk on Cholangiocarcinoma Cell Lines and Foodborne Pathogenic Bacteria

  • Rattanata, Narintorn;Klaynongsruang, Sompong;Daduang, Sakda;Tavichakorntrakool, Ratree;Limpaiboon, Temduang;Lekphrom, Ratsami;Boonsiri, Patcharee;Daduang, Jureerut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1341-1345
    • /
    • 2016
  • Gallic acid was isolated from Caesalpinia mimosoides Lamk and the structure s identified based on spectroscopic analysis and comparison with authentic compound. In this study we compared the ability of natural gallic acid (nGA) and commercial gallic acid (cGA) to inhibit the proliferation of cholangiocarcinoma cell lines (M213, M214) and foodborne pathogenic bacteria (Salmonella spp. and Plesiomonas shigelloides). Both nGA and cGA had the same inhibitory effects on cell proliferation by inducing apoptosis of cholangiocarcinoma cell lines. In addition, nGA inhibited growth of foodborne pathogenic bacteria in the same manner as cGA. Our results suggest that nGA from Caesalpinia mimosoides Lamk is a potential anticancer and antibacterial compound. However, in vivo studies are needed to elucidate the specific mechanisms involved.

Predictable Effect and Usability of Smart-Phone Application for Elderly Dementia Prevention (노인치매예방 스마트폰 앱의 기대효과 및 유용성)

  • Kim, Soo-Jung;Choi, Yun-Jin
    • Journal of Industrial Convergence
    • /
    • v.17 no.4
    • /
    • pp.87-94
    • /
    • 2019
  • The purpose of this study is to predict the usefulness and predictable effects of the use of dementia prevention games and dementia management applications provided in smart-phones for the elderly. First, 6 dementia diagnostic tools used to verify the effectiveness of the dementia prevention program were selected and the cognitive domains tested by each diagnostic tool were extracted. Second, 29 smart-phone dementia prevention game applications and dementia management applications were selected and the expected effects after using these applications were analyzed in connection with the cognitive domain extracted from the dementia diagnosis tool. As a result, it was expected that it would be helpful to manage dementia prevention by improving cognitive function in certain areas when playing games or managing dementia continuously using smart-phone dementia prevention applications. Smart-phone dementia prevention applications will be useful in improving the cognitive ability of the elderly and preventing dementia by supplementing the limitations of the dementia prevention program that is operated offline through time-space ease of use, continuous usability and economic feasibility.

Gallic Acid Enhancement of Gold Nanoparticle Anticancer Activity in Cervical Cancer Cells

  • Daduang, Jureerut;Palasap, Adisak;Daduang, Sakda;Boonsiri, Patcharee;Suwannalert, Prasit;Limpaiboon, Temduang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.169-174
    • /
    • 2015
  • Cervical cancer (CxCa) is the most common cancer in women and a prominent cause of cancer mortality worldwide. The primary cause of CxCa is human papillomavirus (HPV). Radiation therapy and chemotherapy have been used as standard treatments, but they have undesirable side effects for patients. It was reported that gallic acid has antioxidant, antimicrobial, and anticancer activities. Gold nanoparticles are currently being used in medicine as biosensors and drug delivery agents. This study aimed to develop a drug delivery agent using gold nanoparticles conjugated with gallic acid. The study was performed in uninfected (C33A) cervical cancer cells, cervical cancer cells infected with HPV type 16 (CaSki) or 18 (HeLa), and normal Vero kidney cells. The results showed that GA inhibited the proliferation of cancer cells by inducing apoptosis. To enhance the efficacy of this anticancer activity, 15-nm spherical gold nanoparticles (GNPs) were used to deliver GA to cancer cells. The GNPs-GA complex had a reduced ability compared to unmodified GA to inhibit the growth of CxCa cells. It was interesting that high-concentration ($150{\mu}M$) GNPs-GA was not toxic to normal cells, whereas GA alone was cytotoxic. In conclusion, GNPs-GA could inhibit CxCa cell proliferation less efficiently than GA, but it was not cytotoxic to normal cells. Thus, gold nanoparticles have the potential to be used as phytochemical delivery agents for alternative cancer treatment to reduce the side effects of radiotherapy and chemotherapy.

Utility of PET in follow-up of patients with colorectal cancer (대장 직장암 환자의 수술 후 추적 관찰에서 PET의 유용성)

  • Ryu, Young-Hoon;Yun, Mi-Jin;Lee, Jong-Doo
    • 대한핵의학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.17-24
    • /
    • 2002
  • Recurrence of colorectal cancer after apparently curative resection remains common, with reported relapse rates of up to 40%. Because complete resection of solitary metastases or local recurrence may improve long-term survival, surgical management of such cases has become increasingly aggressive but has led to only modest survival benefit. The limitations of current approaches based on structural imaging are well documented, with over half of the patients who are thought suitable for curative surgery being found to have unresectable disease at operation. Therefore, better preoperative assessment is crucial. The increasing use of FDG-PET as an oncologic staging investigation has significantly improved the assessment of patients with suspected colorectal cancer recurrence. Several studios show that substantial and largely appropriate changes in patient management occur, often soaring patients the significant morbidity and mortality associated with aggressive but futile therapies while also saving scarce community resources. Nevertheless, the clinical relevance of these findings has still been questioned. The utility of PET in routine clinical practice will likely depend on its ability to provide incremental information compared with CT in selected patients rather than to serve as a replacement for CT. In conclusion, in patients with suspected recurrent or metastatic colorectal carcinoma, FDG-PET should be performed (1) when there is rising carcinoembryonic antigen levels in the absence of a known source, (2) to increase the specificity of structural imaging when there is an equivocal lesion, and (3) as a screening method for the entire body in the preoperative staging before curative resection of recurrent disease.

  • PDF

$^{99m}Tc-HMPAO$ Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks (일과성 뇌허혈 발작 환자에 있어서 $^{99m}Tc-HMPAO$ 국소 뇌혈류 SPECT의 유용성)

  • Ahn, Myeong-Im;Park, Young-Ha;Lee, Sung-Yong;Chung, Soo-Kyo;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.149-154
    • /
    • 1989
  • Transient ischemic attacks (TIAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed Tc-99m-HMPAO regional cerebral blood flow (rCBF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal Tc-99m-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. Tc-99m-HMPAO rCBF SPECT is sensitive in detecting rCBF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs.

  • PDF

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

  • Tadinada, Aditya;Marczak, Alana;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.141-147
    • /
    • 2017
  • Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose $180^{\circ}$ acquisition protocol versus a conventional $360^{\circ}$ acquisition protocol. Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: $360^{\circ}$ and $180^{\circ}$ cone-beam computed tomography (CBCT) acquisition protocols. A small-volume $180^{\circ}$ CBCT scan and a $360^{\circ}$ CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up $360^{\circ}$ CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement. Conclusion: In this ex vivo study, we found that the $180^{\circ}$ rotational acquisition was as effective as the conventional $360^{\circ}$ rotational acquisition for the preoperative evaluation of potential mini-implant sites.

Evaluation of the Agreement between Immunodot Assays and Intradermal Skin Testing or Favrot Diagnostic Criteria in Canine Atopic Dermatitis

  • Cho, Sun-Hyung;Kang, Ji-Houn;Yang, Mhan-Pyo;Kang, Byeong-Teck
    • Journal of Veterinary Clinics
    • /
    • v.33 no.5
    • /
    • pp.270-273
    • /
    • 2016
  • This study was undertaken to identify differences between atopic and non-atopic dogs in three rapid screening immunodot assays as well as the ability of the assays to predict the results of intradermal skin testing (IDST) or Favrot diagnostic criteria (FDC). Twenty-nine dogs diagnosed with canine atopic dermatitis (CAD) were selected as the atopic group. Twenty-five dogs without CAD were included as the non-atopic group. Three types of immunodot assays were conducted on all serum samples from both groups: Allercept E-screen 2nd generation (ES2G), Canine Allergic Tendency Reference Test (ALERT), and Asan Easy Test Canine IgE (AETC). IDST, which included 39 allergens, and immunodot assays were performed concurrently in 13 dogs from the atopic group and compared. While there were no significant differences in positivity between the two groups in the evaluation of ALERT (P = 0.435) and AETC (P = 0.313), positivity in ES2G testing was significantly higher in the non-atopic group than the atopic group (P = 0.038). The ES2G, ALERT, and AETC results showed fair (${\kappa}=0.235$), slight (${\kappa}=0.133$), and slight (${\kappa}=0.014$) accordance with IDST, respectively. The outcomes of ES2G, ALERT, and AETC indicated poor (${\kappa}=-0.211$), slight (${\kappa}=0.106$), and slight (${\kappa}=0.087$) agreement with FDC. In conclusion, rapid screening immunodot assays were not useful for the diagnosis of CAD. These assays may provide a supplementary method for predicting the results of IDST in atopic dogs.

Periotome versus piezotome as an aid for atraumatic extraction: a randomized controlled trial

  • Mohammed Abdullah, Alraqibah;Jingade Krishnojirao Dayashankara, Rao;Bader Massad, Alharbi
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.6
    • /
    • pp.356-362
    • /
    • 2022
  • Objectives: A single-blinded randomized controlled trial was designed to compare and evaluate the effectiveness of the periotome and piezotome as aids for atraumatic extraction and its sequalae. Materials and Methods: The study sample comprised 48 teeth, equally allotted to the piezotome or periotome groups by random allocation, in participants aged 19-62 years. All samples in both groups had either complete tooth structure or intact roots without crowns and had mobility ≤grade II. Clinical parameters of operative duration, presence or absence of gingival laceration, reported operative and postoperative pain, and intake of analgesics following extraction were recorded. IBM SPSS software package version 22 was used for data entry and analysis. Results: The mean operation time was significantly (P≤0.05) longer in the piezotome group than in the periotome group. However, fewer gingival lacerations were observed with use of a piezotome than with a periotome, although no significant difference was observed. The piezotome group reported significantly (P≤0.05) higher visual analog scale (VAS) pain scores during the procedure and non-significantly higher scores thereafter until the third postoperative day. In the piezotome group, the dosage of analgesic was higher, although the periotome group had a higher percentage of participants who used analgesics postoperatively; however, these differences were not statistically significant. Conclusion: The present clinical trial favors the use of periotome over piezotome for atraumatic extraction due to shorter operating time, lower postoperative VAS pain scores, and lower dosage of analgesics despite the superior ability of the piezotome to prevent gingival laceration.

Development and Usability Evaluation of a Mobile Physical Therapeutic Diagnosis Application (모바일 물리치료 진단 어플리케이션 개발 및 사용성 평가)

  • Min-Hyung Rhee;Jong-Soon Kim
    • PNF and Movement
    • /
    • v.21 no.1
    • /
    • pp.129-137
    • /
    • 2023
  • Purpose: The physical therapy diagnosis process requires high-level background knowledge, the ability to obtain added information from patients, accurate examination skills, and a framework for transforming thoughts into a diagnostic decision. Thus, the physical therapy diagnostic process is highly complicated and difficult work. To function as autonomous professionals, physical therapists must develop effective clinical diagnosis skills. As such, mobile application aids can help with accurate and scientific diagnoses. Therefore, this study aims to develop and evaluate the usability of a mobile application for physical therapy diagnoses. Methods: In this study, a diagnostic application was developed using App Inventor, the development environment was the Chrome web browser for Windows 10, and the mobile application was run on a Google Pixel 5. The developed application was evaluated for usability by 20 physical therapists with more than 5 years of clinical experience in the musculoskeletal physical therapy field, and a usability evaluation was conducted using a 5-point Likert scale for accuracy, convenience, satisfaction, and usability. The collected Likert scores were converted into percentages and analyzed as descriptive statistics. Results: The graphical user interface consisted of an initial screen with program guidance, 18 screens presenting the algorithm, and 12 screens presenting the estimated diagnosis based on the algorithm. As such, the usability evaluation of the developed application was as follows: accuracy 100%, convenience 90%, satisfaction 91%, and usability 88%. Conclusion: The newly developed mobile application for physical therapeutic diagnoses has a high accuracy, and it will aid in building an easy and reliable physical therapy diagnosis system.