• Title/Summary/Keyword: Diagnostic Value

Search Result 1,368, Processing Time 0.029 seconds

Control of clonorchiasis by repeated praziquantel treatment and low diagnostic efficacy of sonography (반복 집단 치료에 의한 간흡충증의 관리 및 진단에서 초음파검사의 저효용성)

  • Sung-Tae HONG;Kisung YOON;Mejeong LEE;Min SEO;Min-Ho CHOI;Jung Suk SIM;Byung Ihn CHOI;Chong Ku YUN;Soon-Hyung LEE
    • Parasites, Hosts and Diseases
    • /
    • v.36 no.4
    • /
    • pp.249-254
    • /
    • 1998
  • In Korea, Clonorchis sinensis infection is still highly prevalent because case detection in the field is difficult and the detected cases used to be incompletely cured due to treatment failure. The present study tried to control clonorchiasis in an endemic village by repeated treatments with praziquantel every 6 months and to evaluate sonography as a diagnostic measure. By stool examinations, the egg positive rate in the endemic village was 22.7%, but it decreased to 19.6% at 6 months. 15.1% at 12 months, 12.2% at 18 months, 6.3% at 24 months, 11.4% at 30 months, and 6.3% at 42 months after the beginning of repeated praziquantel administration. The sonography showed 61 (49.6%) positive cases of 123 screened residents; among egg-positives the sonography positive rate was 52.2% and among egg-negatives it was still 49%. The rate among cured cases was 64.3% after 6 months, 50.0% after 12 months, 50.0% after 18 months, and 66.7% after 24 months. In a non-endemic village, 64 residents were found egg-negative by fecal examination, but 20 (31.3%) of them were positive by sonography. The present findings indicate that control of clonorchiasis in an endemic village by repeated praziquantel treatment for 42 months is still insufficient and sonography is of little value for diagnosis of clonorchiasis.

  • PDF

Follow-Up Method in Patients with Kawasaki Disease who had No Coronary Artery Abnormalities in the Convalescent Period (회복기 심초음파 검사상 관상동맥 내경 크기가 정상 범위인 가와사끼병 환자에서 추적관찰 방법에 대한 고찰)

  • Joo, Hee Jung;Song, Min Seob;Kim, Chul Ho
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.2
    • /
    • pp.165-173
    • /
    • 2005
  • Purpose : We performed the study to evaluate the value of the follow-up echocardiogram performed 6 months to 1 year after the onset of Kawasaki disease(KD), as recommended by American Heart Association(AHA) guidelines, when echocardiograms in the convalescent period were normal. Methods : Patients were selected from 147 cases diagnosed with KD at Pusan Paik hospital from January 2000 to October 2003. A total of 45 KD patients belonged to AHA risk level I and II were performed follow-up echocardiography. The patient's medical records and echocardiogram were reviewed. Additionally, we sought the opinion of pediatric cardiologists on the subject by means of a multiple-choice survey. Results : 37 children were belonged to AHA risk level I and the remaining 8 patients were belonged to risk level II. Of these 45 children, none were noted to have abnormalities on later follow-up echocardiogram. In the results of questionnaire, 37 percent of the participants advocate no follow-up after convalescent period for risk level I, and 33.3 percent favor periodic follow-up with echocardiography for risk level II up to one year. But there were no consensus about the diagnostic criteria of coronary abnormalities and how to follow-up these patients. Conclusion : All children with KD should have an echocardiogram at present and a follow-up study 6 to 8 weeks after the onset of fever. However, additional echocardiographies are not justified if the 6- to 8-week follow-up echocardiogram is normal. We would recommend that the more reasonable diagnostic criteria for coronary abnormalities and the Korean guidelines for long-term cardiovascular management and follow-up of KD need to be established.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.

Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET (폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰)

  • Kim, Joon-Young;Choi, Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Yong-Jin;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.332-343
    • /
    • 1998
  • Purpose: The purpose of this study was to assess the diagnostic accuracy of various quantitation methods using F-18-fluorodeoxyglucose (FDG) in patients with malignant or benign lung lesion. Materials and Methods: 22 patients (13 malignant including 5 bronchoalverolar cell cancer; 9 benign lesions including 1 hamartoma and 8 active inflammation) were studied after overnight fasting. We performed dynamic PET imaging for 56 min after injection of 370 MBq (10 mCi) of FDG. Standardized uptake values normalized to patient's body weight and plasma glucose concentration (SUVglu) were calculated. The uptake rate constant of FDG and glucose metabolic rate were quantified using Patlak graphical analysis (Kpat and MRpat), three compartment-five parameter model (K5p, MR5p), and six parameter model taking into account heterogeneity of tumor tissue (K6p, MR6p). Areas under receiver operating characteristic curves (ROC) were calculated for each method. Results: There was no significant difference of rate constant or glucose metabolic rate measured by various quantitation methods between malignant and benign lesions. The area under ROC curve were 0.73 for SUVglu, 0.66 for Kpat, 0.77 for MRpat, 0.71 for K5p, 0.73 for MR5p, 0.70 for K6p, and 0.78 for MR6p. No significant difference of area under the ROC curve between these methods was observed except the area between Kpat vs. MRpat (p<0.05). Conclusion: Quantitative methods did not improve diagnostic accuracy in comparison with nonkinetic methods. However, the clinical utility of these methods needs to be evaluated further in patients with low pretest likelihood of active inflammation or bronchoalveolar cell carcinoma.

  • PDF

Utility of FDG-PET in Solitary Pulmonary Nodules and the Relationship Between Standardized Uptake Values of PET and Serum Glucose (폐 결절에서 FDG-PET의 유용성과 표준섭취계수와 혈당농도의 상관관계)

  • Kim, Kyu Sik;Lim, Sung Chul;Ko, Young Chun;Park, Kyung Ha;Ju, Jin Young;Jo, Kae Jung;Kim, Soo Ok;Oh, In Jae;Kim, Yu Il;Kim, Young Chul;Kim, Sung Min;Song, Ho Chun;Bom, Hee Seung;Park, Kyung Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.589-596
    • /
    • 2003
  • Background : The solitary pulmonary nodule(SPN) presents a diagnostic dilemma to the physician and the patients in the our nation with high incidence of tuberculoma. We could not exclude whether the SPN was benign or malignant by the change of the size at chest radiograph and findings of chest CT. Recently, positron emission tomography(PET) have been tried as the differential diagnostic method of SPN. We evaluated the efficacy of PET for differentiating malignant from benign SPN and the relationship between standardized uptake values(SUV) of PET and serum glucose. Method : Between January 2001 and July 2002, sixty-one patients with pulmonary nodule were examined by the chest CT and PET. The SPN has been finally diagnosed by the transthorasic needle aspiration and biopsy, bronchoscopic biopsy, and open lung biopsy. Results : Forty eight patients had a malignant nodule(23 squamous cell lung carcinoma, 16 adenocarcinoma, 9 small cell lung cancer) and thirteen patients had a benign nodule(3 tuberculoma, 9 inflammatory granuloma, 1 cryptococcosis). The mean size of malignant and benign nodule was 40.6 mm and 20.0 mm, respectively. All malignant nodules showed a marked increase in 18 fluorodeoxyglucose (FDG) uptake. Mean SUV of malignant was $9.52{\pm}5.20$ and benign nodule was $1.61{\pm}3.60$. There were false positive cases with an increase in 18-FDG uptake (2 tuberculoma, 1 inflammatory granuloma). The SUV of malignant nodule in diabetes patients has no difference in non diabetes patients($9.10{\pm}4.51$ vs $9.65{\pm}5.46$). The sensitivity and specificity of the PET scan for SPN were 100%, 77%, respectively. The positive and negative predictive values were 94% and 100%. Conclusion : PET scanning showed highly accurate result in differentiating the malignant and benign SPN. There were no significant differences between the SUV and serum glucose in the patients with lung cancer.

Time Resolution Improvement of MRI Temperature Monitoring Using Keyhole Method (Keyhole 방법을 이용한 MR 온도감시영상의 시간해상도 향상기법)

  • Han, Yong-Hee;Kim, Tae-Hyung;Chun, Song-I;Kim, Dong-Hyeuk;Lee, Kwang-Sig;Eun, Choong-Ki;Jun, Jae-Ryang;Mun, Chi-Woong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Purpose : This study proposes the keyhole method in order to improve the time resolution of the proton resonance frequency(PRF) MR temperature monitoring technique. The values of Root Mean Square (RMS) error of measured temperature value and Signal-to-Noise Ratio(SNR) obtained from the keyhole and full phase encoded temperature images were compared. Materials and Methods : The PRF method combined with GRE sequence was used to get MR temperature images using a clinical 1.5T MR scanner. It was conducted on the tissue-mimic 2% agarose gel phantom and swine's hock tissue. A MR compatible coaxial slot antenna driven by microwave power generator at 2.45GHz was used to heat the object in the magnetic bore for 5 minutes followed by a sequential acquisition of MR raw data during 10 minutes of cooling period. The acquired raw data were transferred to PC after then the keyhole images were reconstructed by taking the central part of K-space data with 128, 64, 32 and 16 phase encoding lines while the remaining peripheral parts were taken from the 1st reference raw data. The RMS errors were compared with the 256 full encoded self-reference temperature image while the SNR values were compared with the zero filling images. Results : As phase encoding number at the center part on the keyhole temperature images decreased to 128, 64, 32 and 16, the RMS errors of the measured temperature increased to 0.538, 0.712, 0.768 and 0.845$^{\circ}C$, meanwhile SNR values were maintained as the phase encoding number of keyhole part is reduced. Conclusion : This study shows that the keyhole technique is successfully applied to temperature monitoring procedure to increases the temporal resolution by standardizing the matrix size, thus maintained the SNR values. In future, it is expected to implement the MR real time thermal imaging using keyhole method which is able to reduce the scan time with minimal thermal variations.

  • PDF

Age-Based Characteristics of West Syndrome in Patients with Mitochondrial Disease (미토콘드리아 질환에서 웨스트 증후군 환자의 경련 발생 연령에 따른 임상 양상 비교)

  • Choi, Young Ha;Baek, Min-Seong;Na, Ji-Hoon;Kang, Hoon-Chul;Lee, Joon Soo;Kim, Heung Dong;Lee, Young-Mock
    • Journal of the Korean Child Neurology Society
    • /
    • v.26 no.4
    • /
    • pp.197-204
    • /
    • 2018
  • Purpose: West syndrome is a severe form of age-specific epilepsy that typically affects infants younger than 2 years of age with mitochondrial disease. We aimed to examine age-specific characteristics of the syndrome in these patients. Methods: We retrospectively analyzed 54 patients with West syndrome diagnosed with mitochondrial disease between March 2006 and March 2016. We compared treatment strategies and diagnostic and clinical variables between patients with early-onset (<6 months of age) and late-onset (${\geq}6$ months of age) seizures. Results: Seizure was the first symptom in 30 (90.9%) and 13 (65%) patients of the early-onset and late-onset groups, respectively (P=0.046). Delayed development was observed in 3 (9.1%) and 7 (35%) patients of the early-onset and late-onset groups, respectively (P=0.023). Lactate levels were normal in 17 patients (55%) of the early-onset group and 5 (25%) of the late-onset group (P=0.036), while initial brain magnetic resonance imaging (MRI) findings were normal in 23 (67.6%) and 8 (40%) patients of the early-onset and late-onset groups, respectively. Final MRI findings were abnormal in 32 patients (94.1%) of the early-onset group and 18 (90%) of the late-onset group (P=0.036). Although ketogenic diets reduced seizure frequency in both groups, the difference was not significant. Conclusion: There is no significant difference in epilepsy-related variables when patients are divided based on a cut-off age of 6 months. However, differences in the first symptom at onset and MRI findings were observed. Although lactate levels were not of significant diagnostic value in the early-onset group, they may be in the late-onset group.

Diagnostic Evaluation of the BioFire® Meningitis/Encephalitis Panel: A Pilot Study Including Febrile Infants Younger than 90 Days (BioFire® Meningitis/Encephalitis Panel의 진단적 유용성 평가: 90일 미만 발열영아에서의 예비 연구)

  • Kim, Kyung Min;Park, Ji Young;Park, Kyoung Un;Sohn, Young Joo;Choi, Youn Young;Han, Mi Seon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • v.28 no.2
    • /
    • pp.92-100
    • /
    • 2021
  • Purpose: Rapid detection of etiologic organisms is crucial for initiating appropriate therapy in patients with central nervous system (CNS) infection. This study aimed to evaluate the diagnostic value of the BioFire® Meningitis/Encephalitis (ME) panel in detecting etiologic organisms in cerebrospinal fluid (CSF) samples from febrile infants. Methods: CSF samples from infants aged <90 days who were evaluated for fever were collected between January 2016 and July 2019 at the Seoul National University Children's Hospital. We performed BioFire® ME panel testing of CSF samples that had been used for CSF analysis and conventional tests (bacterial culture, Xpert® enterovirus assay, and herpes simplex virus-1 and -2 polymerase chain reaction) and stored at -70℃ until further use. Results: In total, 72 (24 pathogen-identified and 48 pathogen-unidentified) CSF samples were included. Using BioFire® ME panel testing, 41 (85.4%) of the 48 pathogen-unidentified CSF samples yielded negative results and 22 (91.7%) of the 24 pathogen-identified CSF samples yielded the same results (enterovirus in 19, Streptococcus agalactiae in 2, and Streptococcus pneumoniae in 1) as those obtained using the conventional tests, thereby resulting in an overall agreement of 87.5% (63/72). Six of the 7 pathogen-unidentified samples were positive for human parechovirus (HPeV) via BioFire® ME panel testing. Conclusions: Compared with the currently available etiologic tests for CNS infection, BioFire® ME panel testing demonstrated a high agreement score for pathogen-identified samples and enabled HPeV detection in young infants. The clinical utility and cost-effectiveness of BioFire® ME panel testing in children must be evaluated for its wider application.

Association of Serum Copper and Zinc Levels with Liver Cirrhosis and Hepatocellular Carcinoma (간경변 및 간암과 혈청 구리와 아연농도와의 관련성)

  • Hyun, Myung-Soo;Suh, Suk-Kwon;Yoon, Nung-Ki;Lee, Jong-Young;Lee, Seoung-Hoon;Lee, Mu-Sik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.2 s.38
    • /
    • pp.127-140
    • /
    • 1992
  • This study was done to identify the association between serum copper and zinc levels and the cirrhosis and hepatocellular carcinoma(HCC), and to evaluate its diagnostic value on liver diseases. Sixty-three healthy persons, 60 patients with cirrhosis and 33 patients with hepatocellular carcinoma were rendomly selected and investigated for their general characteristics from October 1990 to August 1991. For analysis of the biochemical markers in liver function test and the serum copper and zinc levels, their fasting venous blood were sampled at 9:00 to 11:00 in the morning and centrifuged to separate the serum within one hour. All the samples were immediately analysed for biochemical markers and stored at $-20^{\circ}C$ in polypropylene tubes further copper and zinc analysis. Mean of serum coppper levels was $91.97{\pm}4.76{\mu}g/dl$ in control, $106.21{\pm}2.73{\mu}g/dl$ in cirrhosis and $127.05{\pm}0.77{\mu}g/dl$ in HCC. The value of HCC was statistically significantly higher than that of the control and cirrhosis(p<0.05). Serum zinc levels were $110.82{\pm}7.24{\mu}g/dl$ in control, $68.10{\pm}5.43{\mu}g/dl$ in cirrhosis and $63.78{\pm}2.20{\mu}g/dl$ in HCC. The values of cirrhosis and HCC were statistically significantly lower than that of control(p<0.05). The Cu/Zn ratio was statiatically significantly different among three groups(p<0.05). Test total protein, albumin, ALP and total bilirubin of biochemical markers of liver function were statistically significantly different among three groups(p<0.05). Differences between cirrhosis and HCC for ALT and AST, and between the control and HCC for direct bilirubin were not statistically significant. Biochemical markers statistically significantly correlated with serum copper and zinc levels and Cu/Zn ratio(p<0.05), were variable in three groups. In multiple logistic regression, odds ratio of serum copper level and Cu/Zn ratio had no statistical significance on the cirrhosis and the HCC, but that of serum sinc was statistically significant as 0.951 and 0.952(p<0.05). Serum copper and zinc levels and Cu/Zn ratio were not statistically significantly different between the cirrhosis and HCC. H\Albumin, ALP, zinc, total bilirubin and age among all variables were selected as main variables for three-group discriminant analysis. Percentage of 'grouped' cases correctly classified by these five variables was 98.4 for control, 73.4 for cirrhosis, 75.7 for HCC and 84.0 for all subjects. This study suggests that zinc level is considered to play a role as diagnostic marker on the hepatic disorders and be more useful than serum copper level and Cu/Zn ratio in diagnosis of the liver diseases.

  • PDF

A Study on the Efficacy and Compliance of Oral Appliances according to the Severity of Apnea in the Treatment of Snoring and Obstructive Sleep Apnea (코골이와 폐쇄성수면무호흡증 환자에서 무호흡 심도에 따른 구강내 장치의 치료효과 및 환자의 적응도에 관한 연구)

  • 안홍균;이광호;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.4
    • /
    • pp.419-432
    • /
    • 1998
  • The purpose of this Study was to examine the efficacy and compliance of a mandibular advancement device(MAD) according to the severity of sleep apnea in the snorers and obstructive sleep apnea patients. Fifty-four patients (45 males, 9 females, aged 20 - 68years ) who visited Seoul National Uiversity Dental Hospital(SNUDH) to seek for the treatment of snoring and sleep apnea were classified into four groups according to the results of the nocturnal polysomnography and they were instructed to wear MAD regularly which was designed to increase the size of the upper airway by advancing the mandible. The evaluation of the efficacy and compliance of the MAD according to the severity of apnea and the duration after the usage of MAD ( 1week, 1month, 3months, 6months, 12months) was made by using quesionnaires mad in Department of Oral Medicine and Oral diagnosis, SNUDH. The obtained results were as follows : 1. All subjects results were habitual snoreres and 43 patients(79.6%) complained the loudness of snoring that can be heard out of the room. 2. Apnea index(AI) of the total subjects was mean 29.4$\pm$26.9 and respiratory disturbance index(RDI)was mean 37.6$\pm$28.0. And there was nodifference in the efficacy and the compliances of MAD according to the severity of apnea. 3. The severityi of apnea by the questionnaires significantly corresponded with the results of nocturnal polysomnography, and this fact potentiated the diagnostic value of the questionnaire. 4. after the usage of MAD, there was significant improvement in the frequency of snoring, the loudness of snoring, frequency of apnea, daytime sleepiness nad the refreshment after sleep(p<0.001) regardless of the apnea index(AI) and respiratory distrubance index(RDI). 5. The degree of the satisfaction with MAD was mean 74.4$\pm$18.4% and that of the discomfort with the MAD was 31.4$\pm$19.6%. But there was no serious complication in occlusion and temporomandibular joint with the usage of MAD and the duration of the discomfort was mean 3.3$\pm$2.2 weeks. 6. Forty-one patients(75.9%) continued the usage of MAD but thirteen patients(24.1%) stopped the use of MAD because of the discomforts and insufficient results with it.

  • PDF