• Title/Summary/Keyword: Diagnostic Ultrasound Machine

Search Result 8, Processing Time 0.027 seconds

Survey on Utilization of Ultrasonographic Machine in Small Animal Clinics in South Korea (전국 소동물 병원의 초음파 진단기기 및 활용도 현황조사)

  • Chang, Jin-Hwa;Paik, Min-Ji;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.28 no.4
    • /
    • pp.408-414
    • /
    • 2011
  • This study was carried out to analyze the utilization of ultrasound machines in animal hospitals and focused on surveying the present condition of diagnostic ultrasound on veterinary medicine in South Korea. Total 279 veterinary hospitals were surveyed with e-mail questionnaires or telephone survey. E-mail questionnaires consist of 17 items of questions including existence of ultrasound machine, types of ultrasound machine, ultrasound examination costs, frequency, purposes, other diagnostic imaging equipments, and referring system of ultrasound. Telephone surveys asked about the existence of the ultrasound machine and types of the ultrasound machine to 279 animal hospitals. Two hundred and seventy-one out of 279 animal hospitals holds ultrasound machine. Seventy-two percents clinics purchased used ultrasonographic machines and mean years after the date of manufacture is 7.5 years and the proportion of superannuated machines are relatively high. Also many clinicians prefer single organ scanning rather than general scan technique and more than 60% of clinics perform ultrasonographic examination less than 5 times a week. Clinics located in Seoul area tend to have more expensive and brand-new ultrasonographic machines and the distribution of radiology specialist are higher in this area. Problems associated with the present condition were oversupply of machines, unequal distribution of the medical equipment in different localities, ineffective use of the medical equipment, and high percentage of old poor-quality medical equipments. There should be a viable alternative proposal to control amount and quality of the ultrasound machines. Also, the improved management system for the ultrasound machine is required.

Clinical Situations in which Musculoskeletal Ultrasound is Helpful (근골격계 초음파검사가 도움이 되는 진료 상황)

  • Cho, Kil-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.170-186
    • /
    • 2001
  • Musculoskeletal ultrasound (MSUS) has newly evolved by the mechanical improvement of the machine over past several years, becoming a part of imaging techniques for the evaluation of variable diseases in the musculoskeletal system. MSUS has proven diagnostic superiority in pathologies including rotator cuff disease of the shoulder, lateral epicondylitis of the elbow, diseases of the peripheral nerve, detection of intra-articular loose bodies and soft tissue foreign bodies, and in evaluating small superficial soft tissue tumors such as ganglion, epidermoid cyst, and glomus tumor. Besides, MSUS is very useful for obtaining tissue or fluid via percutaneous fine needle aspiration and/or biopsy for the histopathologic diagnosis. Combining MSUS with MR would play a great role in the field of the diagnostic imaging of the musculoskeletal system. The MSUS examiner should have the knowledge of cross-sectional anatomy, and of the mechanical and physical properties of ultrasound in order to interpret the ultrasound findings accurately and properly, and to avoid diagnostic errors due to variable artifacts subsequently. The goal of this article is to introduce the capabilities of MSUS in certain kinds of clinical situation and to familiarize the reader with MSUS. For the purpose, author intends to describe this article according not to the disease-, or organ-based, but to the clinical problem-based format.

  • PDF

Extracorporeal High Intensity Focused Ultrasound Therapy (체외강력집속초음파치료)

  • Han, Sang-Suk
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • Local treatment for tumors has developed from extended radical surgery to function preserving surgery on the basis of modern biology. With the development of minimally invasive technique, it changed to be minimal-invasive surgery. And nowadays technical revolution made non-invasive surgery possible with appearance of several kinds of non-surgical knives such as gamma knife, cyber knife, and HIFU (high intensity focused ultrasound) knife. In this article, history, HIFU machine and treatment procedure, histological change and its mechanism, clinical applications, advantage, disadvantage, and future prospect of extracorporeal high intensity focused ultrasound therapy using HIFU knife will be reviewed.

  • PDF

Development of Automatic Segmentation Algorithm of Intima-media Thickness of Carotid Artery in Portable Ultrasound Image Based on Deep Learning (딥러닝 모델을 이용한 휴대용 무선 초음파 영상에서의 경동맥 내중막 두께 자동 분할 알고리즘 개발)

  • Choi, Ja-Young;Kim, Young Jae;You, Kyung Min;Jang, Albert Youngwoo;Chung, Wook-Jin;Kim, Kwang Gi
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.100-106
    • /
    • 2021
  • Measuring Intima-media thickness (IMT) with ultrasound images can help early detection of coronary artery disease. As a result, numerous machine learning studies have been conducted to measure IMT. However, most of these studies require several steps of pre-treatment to extract the boundary, and some require manual intervention, so they are not suitable for on-site treatment in urgent situations. in this paper, we propose to use deep learning networks U-Net, Attention U-Net, and Pretrained U-Net to automatically segment the intima-media complex. This study also applied the HE, HS, and CLAHE preprocessing technique to wireless portable ultrasound diagnostic device images. As a result, The average dice coefficient of HE applied Models is 71% and CLAHE applied Models is 70%, while the HS applied Models have improved as 72% dice coefficient. Among them, Pretrained U-Net showed the highest performance with an average of 74%. When comparing this with the mean value of IMT measured by Conventional wired ultrasound equipment, the highest correlation coefficient value was shown in the HS applied pretrained U-Net.

A Diagnostic Feature Subset Selection of Breast Tumor Based on Neighborhood Rough Set Model (Neighborhood 러프집합 모델을 활용한 유방 종양의 진단적 특징 선택)

  • Son, Chang-Sik;Choi, Rock-Hyun;Kang, Won-Seok;Lee, Jong-Ha
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.6
    • /
    • pp.13-21
    • /
    • 2016
  • Feature selection is the one of important issue in the field of data mining and machine learning. It is the technique to find a subset of features which provides the best classification performance, from the source data. We propose a feature subset selection method using the neighborhood rough set model based on information granularity. To demonstrate the effectiveness of proposed method, it was applied to select the useful features associated with breast tumor diagnosis of 298 shape features extracted from 5,252 breast ultrasound images, which include 2,745 benign and 2,507 malignant cases. Experimental results showed that 19 diagnostic features were strong predictors of breast cancer diagnosis and then average classification accuracy was 97.6%.

A TRUS Prostate Segmentation using Gabor Texture Features and Snake-like Contour

  • Kim, Sung Gyun;Seo, Yeong Geon
    • Journal of Information Processing Systems
    • /
    • v.9 no.1
    • /
    • pp.103-116
    • /
    • 2013
  • Prostate cancer is one of the most frequent cancers in men and is a major cause of mortality in the most of countries. In many diagnostic and treatment procedures for prostate disease accurate detection of prostate boundaries in transrectal ultrasound(TRUS) images is required. This is a challenging and difficult task due to weak prostate boundaries, speckle noise and the short range of gray levels. In this paper a method for automatic prostate segmentation in TRUS images using Gabor feature extraction and snake-like contour is presented. This method involves preprocessing, extracting Gabor feature, training, and prostate segmentation. The speckle reduction for preprocessing step has been achieved by using stick filter and top-hat transform has been implemented for smoothing the contour. A Gabor filter bank for extraction of rotation-invariant texture features has been implemented. A support vector machine(SVM) for training step has been used to get each feature of prostate and nonprostate. Finally, the boundary of prostate is extracted by the snake-like contour algorithm. A number of experiments are conducted to validate this method and results showed that this new algorithm extracted the prostate boundary with less than 10.2% of the accuracy which is relative to boundary provided manually by experts.

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

A ProstateSegmentationofTRUS ImageusingSupport VectorsandSnake-likeContour (서포트 벡터와 뱀형상 윤곽선을 이용한 TRUS 영상의 전립선 분할)

  • Park, Jae Heung;Se, Yeong Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.12
    • /
    • pp.101-109
    • /
    • 2012
  • In many diagnostic and treatment procedures for prostate disease accurate detection of prostate boundaries in transrectal ultrasound(TRUS) images is required. This is a challenging and difficult task due to weak prostate boundaries, speckle noise and the short range of gray levels. In this paper a method for automatic prostate segmentation inTRUS images using support vectors and snake-like contour is presented. This method involves preprocessing, extracting Gabor feature, training, and prostate segmentation. Gabor filter bank for extracting the texture features has been implemented. A support vector machine(SVM) for training step has been used to get each feature of prostate and nonprostate. The boundary of prostate is extracted by the snake-like contour algorithm. The results showed that this new algorithm extracted the prostate boundary with less than 9.3% relative to boundary provided manually by experts.