• Title/Summary/Keyword: Diagnostic Monitor

Search Result 145, Processing Time 0.031 seconds

Diagnostic Instruments of PLS-II

  • Kim, Chang-Beom;Kim, Do-Tae;Choe, Jae-Yeong;Lee, Heung-Su;Park, Eung-Su;Sin, Seung-Hwan;Hwang, Jeong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.527-527
    • /
    • 2012
  • In the Pohang Light Source (PLS), a major upgrade (PLS-II) of existing machine had been performed in last 3 years. Big improvements in beam parameters are expected from this major upgrade and various diagnostic instruments were installed to measure them. These include beam position monitor, beam current monitor, tune monitor, scraper, beam loss monitor, photon beam monitor, beam size monitor, streak camera, and so on. In this work, we would like to briefly introduce diagnostic instruments of the PLS-II and present measurement results in the commissioning process of the PLS-II.

  • PDF

Remote Measurement of ECU Self-Diagnostic Signal based on the Windows CE

  • Lee, Seong-Cheol;Yun, Yeo-Hung;Se, Ji-Won;Kwon, Tae-Kyu;Lee, Young-Chun;Jang, Bong-Choon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.68.2-68
    • /
    • 2002
  • The purpose of this paper is to monitor ECU's self-diagnostic signal without wire. In order to measure the ECU's self-diagnostic signal, the interfaced circuit is developed to communicate ECU with a designed display terminal according to the ISO, SAE regulation of communication protocol standard. An 80C196KC processor is used for communicating ECU's self-diagnostic signal and communication data are sent to PDA monitoring system that is based on the Windows CE. Software on PDA is developed to monitor the ECU's self-diagnostic signal in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self-diagnostic signals are verified to mo...

  • PDF

Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA (PDA 기반의 차량 진단신호의 원격 계측)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

Remote Measuring System for Automobile′s ECU Self Diagnostic Signal (자동차 ECU 자기진단 신호의 원격계측 시스템)

  • Jeong, Jin-Ho;Yun, Yeo-Heung;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.5
    • /
    • pp.159-167
    • /
    • 2002
  • In this paper. we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and designed terminal according to the IOS, SAE regulation of communication protocol standard. Micro-processor 80C196KC is used for communicating ECU's self diagnositc signals and the results are sent to the wireless terminal and PC monitoring system. Wireless terminal is also developed by 80C196KC, LCD, RF module, and keypad. The command from the keypad is sent to ECU through RF module and the result show on the Graphic LCD in real time. Software on PC is developed to monitor the ECU's self diagnostic signals using the Visual C++ complier in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor both ECU and portable terminal state. At the same time, the information to fix the vehicle's problem can be shown on the developed software. The possibility for remote measurement of ECU self diagnostic signal is verified through the developed systems and algorithms.

A Study on Quality Assurance(QA) Guideline for Diagnostic Monitor (판독용 모니터 정도관리 항목 및 시행기준안 개발 연구)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jung, Hae-Jo;Jeong, Jae-Ho;Kang, Hee-Doo;Shin, Jin-Ho;Lee, Sun-Geun;Kim, Yong-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.53-65
    • /
    • 2007
  • PACS has been run at the Kyung Hee University Medical Center(KHMC) since 2001, and the installation and operation of PACS have contributed to automation and quantification of KHMC's medical environment During these five years our greatest concern is how to make our own guiding principle of diagnostic monitor QA which is adapted to international standards. In accordance with the terms of 'KHMC QA Guideline', 'AAPM TG18', 'SMPTE RP133', 'DICOM Part14', 'DIN V 6868-57', 'JESRA X-0093', 'JIS Z4752-2-5' and 'KCARE', concern about quality assurance of medical images are on the increase. With the investigation of acceptance testing and quality control of international standards for medical display devices, and data collection and analysis for recommended guideline, it is reported that acceptance testing(quality control), including geometrical distortion, display reflection, luminance response, luminance uniformity, display resolution, display noise, veiling glare and color chromaticity being adequate and effective to domestic hospital environments for medical display devices and assessment methods according to each performance. Accordingly, KHMC classified the checkpoint items by period, at the time of monitor setting, monthly, quarterly, half-yearly and annually. Periodic classification of checkpoint items for monitor QA makes a good guideline for image QA/QC and useful guideline for persistent good quality of monitor.

  • PDF

Space Charge Measurement as a Diagnostic Tool to Monitor Ageing in Polymeric Materials

  • Chen, George
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.235-239
    • /
    • 2006
  • Charge dynamics in polymeric materials after aged under ac electric field using the pulsed electroacoustic (PEA) technique is reported. The emphasis is placed on charge decay. The charge dynamics of the ac aged additive free low density polyethylene (LDPE) samples under dc bias differ from the sample without ac ageing, indicating changes brought in by ac ageing. It is believed that a slow decay rate of charge in the ac aged sample is related to the formation of deep traps in the material. However, chemical analysis by infrared spectroscope (FTIR) and Raman microscope reveals no significant chemical changes taken place in the bulk of the material after ac ageing. Further experiments on irradiated LDPE have revealed a similar behaviour, i.e. the charge decay is slower in irradiated samples than that of fresh sample. The findings presented clearly indicate that space charge measurement can be used as a diagnostic tool to monitor ageing in polymeric materials.

Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs

  • Kim, Tae-Young;Choi, Jin-Woo;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Purpose : The aim of this study was to evaluate the effect of liquid crystal display (LCD) monitor type and observer experience on the diagnostic performance in soft-copy interpretations of maxillary sinus inflammatory lesions on panoramic radiographs. Materials and Methods : Ninety maxillary sinuses on panoramic images were grouped into negative and positive groups according to the presence of inflammatory lesions, using CT for confirmation. Monochrome and color LCDs were used. Six observers participated and ROC analysis was performed to evaluate the diagnostic performance. The reading time, fatigue score, and inter-/intra-observer agreements were assessed. Results : The interpretation of maxillary sinus inflammatory lesions was affected by the LCD monitor type used and by the experience of the observer. The reading time was not significantly different, however the fatigue score was significantly different between two LCD monitors. Inter-observer agreement was relatively good in experienced observers, while the intra-observer agreement for all observers was good with monochrome LCD but not with color LCD. Conclusion : The less experienced observers showed lowered diagnostic ability with a general color LCD.

Self-Diagnostic Signal Monitoring System of KWP2000 Vehicle ECU using Bluetooth

  • Choi, Kwang-Hun;Lee, Hyun-Ho;Lee, Young-Choon;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.132-137
    • /
    • 2004
  • On-Board Diagnostic(OBD) systems are in most cars and light trucks on the load today. During the 1970's and early 1980's manufacturers started using electronic means to control engine functions and diagnose engine problems. The CARB's diagnostic requirements to meet EPA emission standards have been designated as OBD with a goal of monitoring all of the emissions-related components, as well as the chassis, body, accessory devices and the diagnostic control network of the vehicle for proper operation. In this paper, we present a remote measurement system for the wireless monitoring of diagnosis signal and sensors output signals of ECU adopted KWP2000, united the OBD communication protocol, on OBD-compliant vehicle using the wirless communication technique of Bluetooth. In order to measure the ECU signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3C3410X is used for communicating ECU signals. The embedded system's software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on MicroC/OS kernel to communicate between bluetooth modules using bluetooth stack. The diagnostic system is developed using Visual C++ MFC and protocol stack of bluetooth for Windows environment. The self-diagnosis and sensor output signals of ECU is able to monitor using PC with bluetooth board connected in serial port of PC. The algorithms for measuring the ECU sensor output and self-diagnostic signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of self-diagnosis and sensor signals of ECU adopted KWP2000 in embedded system verified through the developed systems and algorithms.

  • PDF

The Analysis of Information Transfer Efficiency in Medical Image Display

  • Kim, Jong-Hyo;Min, Byoung-Goo;Han, Man-Cheong;Lee, Choong-Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.55-57
    • /
    • 1992
  • Image display is the last step of imaging chain in which the diagnostic information is transformed into perceivable intensities and transformed to observer's eye-brain system. In this process, a certain part of information may be efficiently transfered and another part may be inefficiently transfered leading to information loss. In this study, the visual perceptual properties of image display on CRT monitor has been investigated. Psychophysical experiment of target image detection has been performed using CRT monitor for various background grey levels, and the threshold difference grey levels required for visual discrimination have been predicted by computer simulation with visual model.

  • PDF

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF