Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs |
Kim, Tae-Young
(Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University)
Choi, Jin-Woo (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Lee, Sam-Sun (Department of Oral and Maxillofacial Radiology, Dental Research Institute, and BK21 Craniomaxillofacial Life Science, School of Dentistry, Seoul National University) Huh, Kyung-Hoe (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Yi, Won-Jin (Department of Oral and Maxillofacial Radiology, Dental Research Institute, and BK21 Craniomaxillofacial Life Science, School of Dentistry, Seoul National University) Heo, Min-Suk (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) Choi, Soon-Chul (Department of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University) |
1 | Molander B, Grondahl HG, Ekestubbe A. Quality of film-based and digital panoramic radiography. Dentomaxillofac Radiol 2004; 33 : 32-6. DOI ScienceOn |
2 | Ishigaki T, Endo T, Ikeda M, Kono M, Yoshida S, Ikezoe J, et al. Subtle pulmonary disease: detection with computed radiography versus conventional chest radiography. Radiology 1996; 201 : 51-60. DOI |
3 | Goo JM, Choi JY, Im JG, Lee HJ, Chung MJ, Han D, et al. Effect of monitor luminance and ambient light on observer performance in soft-copy reading of digital chest radiographs. Radiology 2004; 232 : 762-6. DOI ScienceOn |
4 | Arenson RL, Chakraborty DP, Seshadri SB, Kundel HL. The digital imaging workstation. Radiology 1990; 176 : 303-15. DOI |
5 | Lee SS, Choi SC. Radiographic examination for successful dental implant. Korean J Oral Maxillofac Radiol 2005; 35 : 63-8. |
6 | Pavlicek W, Owen JM, Peter MB. Active matrix liquid crystal displays for clinical imaging: comparison with cathode ray tube displays. J Digit Imaging 2000; 13(2 Suppl 1) : 155-61. DOI |
7 | Herron JM, Bender TM, Campbell WL, Sumkin JH, Rockette HE, Gur D. Effects of luminance and resolution on observer performance with chest radiographs. Radiology 2000; 215 : 169-74. DOI |
8 | Potchen EJ, Cooper TG, Sierra AE, Aben GR, Potchen MJ, Potter MG, et al. Measuring performance in chest radiography. Radiology 2000; 217 : 456-9. DOI |
9 | Quekel LG, Kessels AG, Goei R, van Engelshoven JM. Detection of lung cancer on the chest radiograph: a study on observer performance. Eur J Radiol 2001; 39 : 111-6. DOI ScienceOn |
10 | Koymen R, Gocmen-Mas N, Karacayli U, Ortakoglu K, Ozen T, Yazici AC. Anatomic evaluation of maxillary sinus septa: surgery and radiology. Clin Anat 2009; 22 : 563-70. DOI ScienceOn |
11 | Hyun YM, Lee SS, Choi SC. Comparison of Waters' radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening. J Korean Acad Oral Maxillofac Radiol 1998; 28 : 261-9. |
12 | Lee ES, Park CS. Usefulness of panoramic radiography in the detection of maxillary sinus pathosis. J Korean Acad Oral Maxillofac Radiol 1999; 29 : 223-39. |
13 | Hellen-Halme K, Nilsson M, Petersson A. Effect of monitors on approximal caries detection in digital radiographs - standard versus precalibrated DICOM part 14 displays: an in vitro study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 107 : 716-20. DOI ScienceOn |
14 | Partan G, Mayrhofer R, Urban M, Wassipaul M, Pichler L, Hruby W. Diagnostic performance of liquid crystal and cathoderay-tube monitors in brain computed tomography. Eur Radiol 2003; 13 : 2397-401. DOI ScienceOn |
15 | Heo MS, Han DH, An BM, Huh KH, Yi WJ, Lee SS, et al. Effect of ambient light and bit depth of digital radiograph on observer performance in determination of endodontic file positioning. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 105 : 239-44. DOI ScienceOn |
16 | Heo MS, Choi DH, Benavides E, Huh KH, Yi WJ, Lee SS, et al. Effect of bit depth and kVp of digital radiography for detection of subtle differences. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108 : 278-83. DOI ScienceOn |
17 | Wenzel A, Haiter-Neto F, Gotfredsen E. Influence of spatial resolution and bit depth on detection of small caries lesions with digital receptors. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 103 : 418-22. DOI ScienceOn |
18 | Pjetursson BE, Tan WC, Zwahlen M, Lang NP. A systematic review of the success of sinus floor elevation and survival of implants inserted in combination with sinus floor elevation. J Clin Periodontol 2008; 35 : 216-40. |
19 | Otto D, Bernhardt TM, Rapp-Bernhardt U, Ludwig K, Kastner A, Liehr UB, et al. Subtle pulmonary abnormalities: detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies. Radiology 1998; 207 : 237-42. DOI |
20 | Tan WC, Lang NP, Zwahlen M, Pjetursson BE. A systematic review of the success of sinus floor elevation and survival of implants inserted in combination with sinus floor elevation. Part II: transalveolar technique. J Clin Periodontol 2008; 35 : 241-54. DOI |
21 | Weatherburn GC, Ridout D, Strickland NH, Robins P, Glastonbury CM, Curati W, et al. A comparison of conventional film, CR hard copy and PACS soft copy images of the chest: analyses of ROC curves and inter-observer agreement. Eur J Radiol 2003; 47 : 206-14. DOI ScienceOn |
22 | Slasky BS, Gur D, Good WF, Costa-Greco MA, Harris KM, Cooperstein LA, et al. Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images. Radiology 1990; 174 : 775-80. DOI |
23 | Thaete FL, Fuhrman CR, Oliver JH, Britton CA, Campbell WL, Feist JH, et al. Digital radiography and conventional imaging of the chest: a comparison of observer performance. AJR Am J Roentgenol 1994; 162 : 575-81. DOI ScienceOn |
24 | MacMahon H, Vyborny CJ, Metz CE, Doi K, Sabeti V, Solomon SL. Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance. Radiology 1986; 158 : 21-6. DOI |
25 | Gotfredsen E, Wenzel A. Integration of multiple direct digital imaging sources in a picture archiving and communication system (PACS). Dentomaxillofac Radiol 2003; 32 : 337-42. DOI ScienceOn |
26 | Pisano ED, Cole EB, Kistner EO, Muller KE, Hemminger BM, Brown ML, et al. Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display. Radiology 2002; 223 : 483-8. DOI ScienceOn |