• Title/Summary/Keyword: Diagnostic Imaging: Radiography

Search Result 230, Processing Time 0.02 seconds

Analysis of the Importance of Subjects to Improve the Educational Curriculum in the Radiological Science - Focused on Radiological Technologists - (방사선(학)과 교육과정 개선을 위한 교과목 중요도 분석 - 방사선사를 중심으로 -)

  • Kim, Jung-Hoon;Ko, Seong-Jin;Kang, Se-Sik;Kim, Dong-Hyun;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.125-132
    • /
    • 2012
  • In this study a group of experts and clinical radiological technologists were surveyed to evaluate the clinical importance of current subjects in the radiological sciences. For the data collection and analysis, an open-ended questionnaire was distributed to the group of experts, and a multiple choice questionnaire was distributed to radiological technologists. Subjects were classified into 9 groups for analysis of the importance of subjects, and in regard to the questionnaire design for measurement of variables, departments and type of hospital were set up as independent variables, and the 9 groups of subjects were set up as dependent variables. As a result, clinical radiological technologists perceived Diagnostic Imaging Technology and practical courses, including general radiography, CT and MRI, as the most clinically necessary subjects, and the group of experts placed most weight on basic courses for the major. The result of this study suggests that the curriculum should be revised in a way that combines theory and practice in order to foster radiological technologists capable of adapting to the rapidly changing healthcare environment.

Efficiency and accuracy of artificial intelligence in the radiographic detection of periodontal bone loss: A systematic review

  • Asmhan Tariq;Fatmah Bin Nakhi;Fatema Salah;Gabass Eltayeb;Ghada Jassem Abdulla;Noor Najim;Salma Ahmed Khedr;Sara Elkerdasy;Natheer Al-Rawi;Sausan Alkawas;Marwan Mohammed;Shishir Ram Shetty
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.193-198
    • /
    • 2023
  • Purpose: Artificial intelligence (AI) is poised to play a major role in medical diagnostics. Periodontal disease is one of the most common oral diseases. The early diagnosis of periodontal disease is essential for effective treatment and a favorable prognosis. This study aimed to assess the effectiveness of AI in diagnosing periodontal bone loss through radiographic analysis. Materials and Methods: A literature search involving 5 databases (PubMed, ScienceDirect, Scopus, Health and Medical Collection, Dentistry and Oral Sciences) was carried out. A specific combination of keywords was used to obtain the articles. The PRISMA guidelines were used to filter eligible articles. The study design, sample size, type of AI software, and the results of each eligible study were analyzed. The CASP diagnostic study checklist was used to evaluate the evidence strength score. Results: Seven articles were eligible for review according to the PRISMA guidelines. Out of the 7 eligible studies, 4 had strong CASP evidence strength scores (7-8/9). The remaining studies had intermediate CASP evidence strength scores (3.5-6.5/9). The highest area under the curve among the reported studies was 94%, the highest F1 score was 91%, and the highest specificity and sensitivity were 98.1% and 94%, respectively. Conclusion: AI-based detection of periodontal bone loss using radiographs is an efficient method. However, more clinical studies need to be conducted before this method is introduced into routine dental practice.

Multicentric Epithelioid Angiosarcoma of Bones Showing Angiotropic Spread: A Case Report (뼈에 발생한 혈관성 파종 양상을 보이는 다발성 상피상 혈관육종: 증례 보고)

  • Woo Suk Choi;Seul Ki Lee;Jee-Young Kim;Jun-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.240-246
    • /
    • 2024
  • Epithelioid angiosarcoma is a rare variant of angiosarcoma characterized by an epithelioid morphology that mimics carcinoma. Therefore, multicentric epithelioid angiosarcoma is easily misdiagnosed as bone metastasis from carcinoma and has an aggressive clinical course. Here, we present a rare case of a 61-year-old male with multicentric epithelioid angiosarcoma of the bone. Plain radiography, CT, and MRI revealed multiple osteolytic lesions in both femurs; some lesions showed soft tissue extension with cortical bone destruction. Interestingly, PET-CT revealed that the lesions were only distributed along the bones of the lower extremities, including the pelvic bones, femurs, and tibiae. Despite histological analysis initially suggesting metastatic carcinoma, after additional immunohistological staining, including that for vascular markers (CD31 and ERG), the final diagnosis was epithelioid angiosarcoma. A better understanding of the clinicoradiological features of this disease may help eliminate diagnostic confusion and provide better management.

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF

Clinical Usefulness of Chest Wall Ultrasonography for Detecting Fractures of Costal Cartilage due to Minor Blunt Chest Trauma (경미한 둔상에 의하여 야기되는 늑연골 골절 진단에 있어서 흉벽 초음파 검사의 임상적 유용성)

  • Lee, Woo-Surng;Kim, Yo-Han;Chee, Hyun-Keun;Hwang, Jae-Joon;Lee, Song-Am;Jung, Ho-Sung;Shin, Hyun-Joon;Choi, Young-Chill
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.502-508
    • /
    • 2009
  • Background: Rib fractures are the most common injuries that are caused by blunt chest trauma. However, fractures of the costal cartilage generally go unnoticed on chest X-rays unless they involve a calcified cartilage. For this reason, the sensitivity of conventional radiography for detecting rib fractures is low, and especially those involving the cartilaginous part of the rib. Thus, we have evaluated the usefulness of ultrasonography for detecting fractures of the costal cartilage that were overlooked on the conventional radiographs of patients who suffered minor blunt chest traumas. Material and Method: A total of 45 patients who suffered minor blunt chest trauma and who had no evidence of rib fractures or other major fractures on conventional radiographs were admitted for ultrasonography between April 2008 and March 2009. There were 24 women and 21 men, and the mean age of the patients was 50.4$\pm$15.91 years (range: 17$\sim$76 years). They were examined for the detection of fractures of the costal cartilage by performing ultrasonography with a 7.5-MHz linear transducer. Result: A total of 30 patients (67%) had fractures of the costal cartilage, whereas 15 patients (33%) had no evidence of chondral rib fractures. The mean number of fracture sites of the fractured costal cartilage was 1.6$\pm$0.81 (range: 1$\sim$4 sites) in 30 patients. Periosteal hematoma was the most common finding associated with fractures of the costal cartilage (n=7, 17%), followed by sternum fracture (n=5, 12%). However, periosteal hematoma was noticed in 1 patient (2%) who was without fracture of the costal cartilage, and sternum fracture was noticed in 1 patient (2%) who was without fractures of the costal cartilage. Conclusion: The results of this study suggest that ultrasonography may be a useful imaging modality for detecting fractures of the costal cartilage that are overlooked on the conventional radiographs of patients who suffer minor blunt chest trauma.

Radiographic, MRI and Histopathologic Assessment to Standardize Canine Spinal Cord Injury Model (척수손상 모델 견 표준화를 위한 방사선, 자기공명영상 및 조직 병리 평가)

  • Seong, Yun-Sang;Yun, Sung-Ho;Park, Jai-Soon;Kim, Hee-Kyung;Chang, Yong-Min;Ku, Sae-Kwang;Park, Hyun-Jeong;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.5
    • /
    • pp.546-552
    • /
    • 2010
  • Previous studies could not offer available guideline to decide size of balloon and grade of injury before induction of spinal cord injury (SCI) because grade of SCI was assessed after inserting a catheter and each experimental animal were different in body size and weight as well as in species. This study was performed to provide guideline for standardized SCI model. Eight healthy adult beagle dogs that had 8 mm of spinal canal height were assigned to four groups according to the diameter of balloon and compression time: 4 mm/3hrs, 4 mm/6hrs, 4 mm/12hrs and 6 mm/3hrs group. Radiography was performed to standardize between experimental animal and balloon before selecting balloon diameter to induce SCI. Behaviors outcomes, somatosensory evoked potentials (SEPs), magnetic resonance imaging (MRI) and histopathological examination were evaluated. Behaviors outcomes and SEPs were not available to assess grade of SCI and those only indicate SCI. The damaged area was revealed clear hyperintensity on STIR image and T2WI after induction of SCI. The hyperintense area on MRI was cranially and caudally expanded with increasing of the diameter of balloon or the compression time. Well corresponded to expanding of hyperintense area on MRI, the damaged region and the numbers of caspase-3 and PARP immunoreactive cells were increased on histopathological findings. Therefore, these results will be considered fundamental data to induce standardized SCI model in experimental animal that has various weight and size.

Clinical Significance of MR Imaging for the Diagnosis and Treatment of Subungual Glomus Tumor in the Fingers (수지 조갑하 사구종의 진단 및 치료에서 자기 공명 영상의 임상적 의미)

  • Kim, Byoung-Suck;Kim, Woo-Sig;Han, Kyoung-Jin;Cho, Jae-Hyun;Lee, Kyi-Beom;Ha, Heon-Kyo;Kang, Shin-Young
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2001
  • Purpose : Authors investigated the efficiency of preoperative MRI in suspicious glomus tumor and the clinical outcomes after marginal excision. Materials and Methods : In 10 cases of glomus tumors in the fingers, authors retrospectively analyzed the clinical data, including previous trauma, treatment history, preoperative symptoms, physical examination, plain radiography, MRI (9 cases), pathological findings and postoperative complications. Results : The patients had pain in 10 cases, tenderness in 9 cases, cold sensitivity in 3 cases and edema in one case. MRI showed low signal (3 cases) or iso-signal (5) intensity on T1 weighted image, high signal intensity (8) on T2 weighted image, and all the lesions were enhanced in gadolinium enhancement images. The exact locations of glomus tumors were median in 6 cases, lateral in 5, lateral fold in 2 and pulp in 3 in transverse section and nail bed in 5 cases and nail matrix in 5 in sagittal section. Marginal excision was performed by lateral approach in one case and transungual in 9 cases. Histologically, all 10 cases were composed of solid sheets of round cells interrupted by thin-walled blood vessels. Most of clinical symptoms were disappeared in all cases after operation. Nail deformity was found in one case, which was originated from nail matrix, however, there was no recurrence. Summary : Clinical symptom was the most impotant factor in diagnosis of glomus tumor in the fingers. However, preoperative MRIs were helpful in patients, who had obscure pain or prolonged clinical symptoms with suspicious glomus tumors. Preoperative MRI might be one of the most useful tools for establishing the exact diagnosis and detecting the location of glomus tumors, in spite of the relatively high expenses.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.