• Title/Summary/Keyword: Diagnostic Evaluation

Search Result 1,572, Processing Time 0.039 seconds

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Improved Acroparesthesia During Enzyme Replacement Therapy in a Patient Lately Diagnosed with Fabry Disease (진단이 지연된 Fabry 병 환자에서 효소대체요법을 통한 사지 말단 동통의 호전을 보인 1례)

  • Yang, Aram;Kim, Jinsup;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.17 no.3
    • /
    • pp.92-95
    • /
    • 2017
  • Fabry disease (FD) is an X-linked lysosomal storage disorder caused by an ${\alpha}$-galactosidase A (GLA, MIM 300644) enzyme deficiency due to pathogenic variants in the ${\alpha}$-galactosidase A gene (GLA). The disease leads to accumulation of globotriaosylceramide (Gb3) and related glycophospholipids affecting nearly all major organ systems, with the primary sites damaged by Gb3 including renal glomeruli, myocardium, neurons of the dorsal ganglion and autonomic nervous system, and vascular endothelial and smooth muscle. Progressive deposition in these organ systems present with various clinical manifestations including acroparesthesia, renal failure and heart failure. Here, we report a Chinese male diagnosed with Fabry disease in his late $4^{th}$ decades showing improvement of acroparesthesia during enzyme replacement therapy (ERT). A 48-year-old Chinese man who presented with chronic recurrent severe burning pain in his fingers and toes since the age of 10, with worse involvement of the former visited to our clinic for further evaluation. His medical history included a transient ischemic attack aged 40 and diagnosed with stage 4-5 chronic kidney disease aged 47. In the family history, the patient's brother was found to be have Fabry disease 1 month before his visit. Except for his brother, all other members of the family are healthy. Based on his medical history and family history, he was strongly suspicious for Fabry disease. He was found to have a galactose-alpha-1,3-galactose level 4.96 (Reference range, 42.5-67.9) suggestive of Fabry disease. The followed sequencing of GLA coding region in our patient revealed hemizyosity for the mutation c.988C>T (Q330X) in Exon 7. Since ERT start, he showed significant improvement in his symptoms of burning sensation of fingers and toes. On the contrary, due to deteriorating kidney function even with ERT, he is considered for kidney transplantation. Despite of diagnostic delay until late 4th decades, ERT showed a potential improvement of acroparesthesia in our patient. However, late start of ERT can lead to poor outcome in multiorgan function. Therefore, early diagnosis with high index of suspicion followed by continuous ERT with regular monitoring have an impact on quality of life in Fabry disease.

  • PDF

Clinical Evaluation of Patients with Unilateral Non-functioning Kidney on $^{99m}Tc-DMSA$ scan ($^{99m}Tc-DMSA$ 스캔에서 일측성으로 동위원소 섭취가 안되는 환아들에 대한 임상적 고찰)

  • Bae Hyun-Chul;Kim Hyun-Young;Kim Pyung-Kil;Han Sang-Won
    • Childhood Kidney Diseases
    • /
    • v.1 no.1
    • /
    • pp.31-37
    • /
    • 1997
  • The DMSA scan is a useful radiologic study in diagnosis of morphologic and functional diseases of kidney. We evaluated the distribution of sex and age, clinical manifestations, diagnosis, combined diseases, treatment and prognosis of the 61 patients with non-functioning kidney(no isotope uptake or uptake below 5% in DMSA scan) who admitted in our hospital from 1980 to 1995. The proportion of patients under 1 year old age was 46%. Sex ratio was 1.4:1 with male predominance. Most diagnosis of non-functioning kidneys were congenital such as multicystic dysplastic kidney, hydronephrosis due to ureteropelvic junction obstruction, renal agenesis and renal hypoplasia. In order of frequency thirty one percent of them were previously detected on antenatal ultrasonogram. Treatment consisted of operation in 47.5%, mostly nephrectomy and 32.8% of patients were followed up at OPD base without definite treatment. The most common combined diseases was hydronephrosis, in 4patients who had both kidneys inveloved progressed to chronic renal failure, but the prognosis in most cases were good. It is important to evaluate renal diseases in perinatal periods, and we believe that highly sensitive diagnostic study contribute to early treatment plan and thus to good prognosis.

  • PDF

Study of Post Procedural Complications Associated with Voiding Cystourethrography (소아에서 시행한 방광요도 조영술 이후 발생한 합병증에 대한 고찰)

  • Kim, Min-Sun;Lee, Seung-Hyun;Kim, Jeong-Hwa;Chang, Young-Bum;Lee, Dae-Yeol
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • Purpose : Voiding cystourethrography(VCUG) is a commonly performed diagnostic procedure in children with urinary tract infections. Recently, with the widespread use of prenatal ultrasonography, VCUG is performed as part of the postnatal radiological evaluation of asymptomatic infants with prenatally detected hydronephrosis. The procedure is relatively simple but it involves discomfort and some complications. We studied post procedural symptoms and complications in children who underwent VCUG. Methods : This study reviewed 259 patients who underwent VCUG in our hospital between October 2005 and September 2006. We did a chart review and a telephone interview with the patients' parents about symptoms and complications associated with VCUG. Results : Among 269 children, 217 patients(80.7%) were under 2 years of age and 5 patients (1.9%) were over 8 years of age. Their mean age was $13.1{\pm}22.9$ months. After VCUG, dysuria was found in 49 patients presented with dysuria, and irritability in 36 patients with irritability. Other complications were hematuria, fever, frequency, bladder rupture and urinary tract infection. Mean symptoms duration was $1.4{\pm}0.7$ days. There was no significant relationship between prophylactic antibiotics use and complication rate associated with VCUG. Conclusion : Our study demonstrated that 32.7% of patients showed complications including bladder rupture and urinary tract infection after VCUG. We also found that prophylactic antibiotics use did not prevent urinary tract infection nor decrease the rate of complications associated with VCUG. Therefore, we suggest that the procedure must be done carefully and aseptically, and we should closely observe the children who undergo VCUG for development of possible complications.

  • PDF

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

Changes of Serum Troponin-T Concentrations in Patients with Open Heart Surgery (개심술환자에 있어 혈청 Troponin-T 농도의 변화에 관한 연구)

  • 박동욱;최석철;김윤규;박종원;조관현
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.125-133
    • /
    • 1998
  • This study was designed to identify the efficiency of serum troponin-T(s-TnT) level as a diagnostic indicator for the perioperative myocardial damage with open heart surgery(OHS) and to compare with the conventional myocardial enzyme tests such as isoenzyme fraction of creatine kinase(% CK-MB) and isoenzyme ratio of lactate dehydrogenase(LDH1/LDH2 ratio). The study was performed on 30 adult patients who underwent OHS from Jan. 1996 to June 1996 at Inje University Pusan Paik Hospital, and they were divided into two groups accor- ding to aortic clamping time(ACT) duration : group I(ACT<60 minutes, n=15); group II (ACT>60 minutes, n=15). S-TnT, % CK-MB, and LDH1/LDH2 ratio were measured in serial blood samples from all subjected patients. The results were obtained as follows. 1. In both groups, s-TnT concentrations increased gradually during OHS and elevated significantly at CPB-10(p<0.001). The peak level was noticed at POD 1 in group I(1.10 $\pm$0.19 ng/ml), whereas, at CPB-off in group II(1.88$\pm$0.42 ng/ml). The elevated levels remained until POD 7 in both groups. 2. %CK-MB was risen significantly with the initiation of operations(p<0.001) and the peak levels were noticed at CPB-off in both groups(7.14$\pm$0.86% in group I, 10.69$\pm$1.27% in group II). Thereafter, these levels returned to normal values at POD 3. 3. There were no significant changes in the values of LDH1/LDH2 ratio during and after OHS compared with the control levels(p>0.05). 4. The serial changes of s-TnT were relatively well correlated with those of changes of % CK-MB(r=0.64, p<0.05). 5. The serial s-TnT levels were significantly higher in group II than group I from B-ACR to POD 1(p<0.05), suggesting that duration of aortic clamping time was a major factor concerned with perioperative myocardial injury. In conclusion, measurement of s-TnT is a very useful indicator in assessing the myocardial cell damage and therefore it is expected that serial checking and evaluation of the s-TnT is very available for identification of the perioperative myocardial damage and for postoperative cares in patients with OHS.

  • PDF

Clinical Analysis of Video Assisted Thoracic Surgery for the Treatment of Thoracic Empyema (비디오 흉강경을 이용한 농흉수술의 임상분석)

  • Oh, Sang-Gi;Song, Sang-Yun;Yun, Chi-Hyeong;Na, Kook-Ju;Kong, Kang-Eun;Park, Song-Ran;Kim, Sang-Hyung
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Background: Thoracic empyema remains a serious problem despite the availability of modern diagnostic methods and appropriate antibiotics. The condition presents in many different forms and stages that require different therapeutic options. Video-assisted thoracic surgery (VATS) has become increasingly popular for use in the treatment of empyema. Material and Method: From January 2005 to May 2009, VATS was performed in 36 patients with pleural empyema and for whom chest-tube drainage and antibiotic therapy had failed or the CT scan showed multiseptate disease. The perioperative clinical factors were analyzed for all the study patients. Result: All the patients underwent VATS, but it was necessary to convert to thoracotomy in one patient. The mean operation time was $90{\pm}38.5\;min$. For the operative evaluation, 11 patients were compatible with ATS stage III. The duration of chesttube insertion was $11.9{\pm}5.8$ (3~24) days. One patient did not improve and therefore this patient underwent additional open drainage. At discharge, costophrenic angle blunting was observed in 22 patients, pleural thickening was noted in 20 patients, both were noted in 17 patients and neither was noted in 11 patients. However, at follow-up, each of these changes was observed in 9, 7, 4 and 24 patients, respectively. All except one patient showed radiographic improvement. Conclusion: VATS is suitable for the treatment of early and fibrinopurulent thoracic empyema, and even in selected patients with stage III disease.

Present Conditions of Mental Health Care in Rural Areas: Community Mental Health Program of Public Health Center (농촌지역 정신보건관리실태: 보건소 지역사회정신보건사업)

  • Lee, Weon-Young;Kim, Dong-Moon
    • Journal of agricultural medicine and community health
    • /
    • v.28 no.2
    • /
    • pp.1-14
    • /
    • 2003
  • Objectives: This paper introduces need and supply level of rural mental health care service and especially focuses on the evaluation for the community mental health programs of Public Health Centers(PHCs) in rural areas as the facilities for primary mental health care. Methods: We defined the need as prevalance rate and service utilization rate, for which reviewed the results of the epidemiological study of mental disorders using Korean Composite International Diagnostic Interview surveyed on a nationwide scale in 2001. Supply was appraised in terms of psychiatric beds and primary mental heath care facilities such as private psychiatric clinics, facilities for social rehabilitation, PHCs running community mental health programs. For this, we reveiwed a variety of annual reports related mental health published by Ministry of Health and Welfare. To evaluate the community mental health programs of PHCs in rural areas, we selected. randomly samples out of the 3rd community health plans including the contents of community mental health programs, which submitted by 89 rural counties and 44 cities mixed with rural areas, and used the program's guideline established by central government as a standard. Results: Prevalence rates of major psychiatric diseases such as schizophrenia, alcoholism, major depression, anxiety disorder were higher in rural area than in urban area and 8.9% of psychiatric patients in both areas stayed at homes contacted with mental health manpower more than one time during the last year. Psychiatric beds were sufficiently supplied, but urban area had less beds than rural area contrary to general health care service. Psychiatric clinics were supplied very insufficiently in rural areas and PHCs bridged the gap instead. However rural PHCs got less financial support for community mental health programs from higher positioned agencies than urban PHCs. Rural community health programs not supported hardly worked out. Conclusions: Central government should consider a special policy for rural primary mental health care, because private psychiatric clinics can't be introduced in rural areas due to demand-deficiency and the financial independence of rural counties was very vulnerable.

  • PDF