• 제목/요약/키워드: Diagnosis related group

검색결과 474건 처리시간 0.028초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

폐암환자에서 혈청 CEA, SCC, Cyfra21-1, TPA-M 측정의 의의 (Clinical Application of Serum CEA, SCC, Cyfra21-1, and TPA in Lung Cancer)

  • 이준호;김경찬;이상준;이종국;조승재;권건영;한승범;전영준
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권4호
    • /
    • pp.785-795
    • /
    • 1997
  • 연구배경 : 종양 표지자는 각종 악성 종양의 진단, 진행정도, 절제 가능성, 예후추정, 치료후 추적 검사 등에도 사용될 수 있으나 민감도와 특이도가 만족스럽지 못한 경우가 많아서 임상에서 보조적인 수단으로 이용되고 있는 경우가 대부분이다. 최근 Cyfra21-1이 비소세포 폐암의 진단에 CEA, SCC보다 우수하다는 보고가 있었고 단일클론 항체를 이용한 TPA-M(Tissue polypeptide antigen)이 비소세포 폐암은 진단하는데 상당히 우수한 결과를 보인다고 보고하고 있다. 이에 폐암환자에서 혈청 CEA, SCC, Cyfra21-1, TPA-M의 임상적 유용성을 서로 비교해 보고자 이 연구를 시행하였다. 방 법 : 1996년 4월 1일 부터 19961건 8월 31일까지 계명대학교 의과대학 병원에 내원한 환자중 조직 생검으로 확진된 비소세포 폐암 37예와 소세포 폐암 12예를 총 49예를 폐암 환자군으로 같은 기간의 입원 환자 중 양성 양성 폐질환으로 확진된 29예를 대조군으로 선정하였고 폐암 환자의 경우 수술, 항암요법 및 방사선치료를 전혀 시행하지 않은 상태에서 혈청을 채취하여 검사를 시행하였다. CEA는 일본 Eiken사의 Ab bead CEA, SCC는 미국 DAINABOT사의 SCC RIA BEAD kit, Cyfra21-1은 일본 TFB사의 CA 21-1 kit, TPA-M은 일본 DAIICHI사의 TPA-M kit를 사용하였다. 결 과 : 전체 폐암환자와 대조군을 비교해보면 CEA가 $10.05{\pm}38.39{\mu}/L$, $1.59{\pm}0.94{\mu}/L$, SCC가 $3.04{\pm}5.79{\mu}/L$, $1.58{\pm}2.85{\mu}/L$, Cyfra21-1이 $8.27{\pm}11.96{\mu}/L$, $1.77{\pm}2.72{\mu}/L$, TPA-M이 $132.02{\pm}209.35U/L$, $45.86{\pm}75.86U/L$으로 나타났으며 Cyfra21-1과 TPA-M은 폐암환자에서 대조군보다 종양 표지자의 측정치가 유의하게 높았다.(p<0.05) CEA, Cyfra21-1, TPA-M, SCC의 cutoff value를 회사에서 권장하는 $2.5{\mu}/L$, $3.0{\mu}/L$, 70.0U/L, $2.0{\mu}/L$로 하였을 때 전체폐암에 대한 민감도와 특이도는 CEA 33.3%와 78.6%, Cyfra21-1 50.0%와 89.7%, TPA-M 52.3%와 89.7%, SCC 23.8%와 89.3%이었으며 비소세포 폐암에 대하여서는 CEA 36.1%와 78.1%, Cyfra21-1 50.1%와 89.7%, TPA-M 53.1%와 89.7%, SCC 33.8%와 89.3% 소세포 폐암의 경우에도 CEA 25.0%와 78.5%, Cyfra21-1 50.0%와 89.6%, TPA-M 50.0%와 89.6%, SCC 0%와 89.2%로 폐암환자에서 Cyfra21-1과 TPA-M이 민감도와 특이도에 있어 더 우수한 결과를 보였고 비소세포 폐암환자에서 SCC도 높은 특이도를 나타내었다. ROC(Receiver operating characteristic) curve에 따라 민감도와 특이도를 얻어 가장 정확도가 높은 cutoff value를 CEA $1.25{\mu}/L$, Cyfra21-1 $1.5{\mu}/L$, TPA-M 35U/L, SCC $0.6{\mu}/L$로 하여 민감도와 특이도, 정확도 및 kappa index를 비교해 보아도 Cyfra21-1과 TPA-M이 더 우수한 결과를 나타내었다. 병기에 따른 비소세포 폐암에서의 종양 표지자를 3A 병기까지와 3B 병기이상으로 나누어 비교해보면 3B 병기이상에서 SCC에서만 통계적 유의성을 보였다. (p<0.05) 그러나 종양크기에 따른 종양표지자의 측정치는 통제적 유의성이 없었다.(p>0.05) 결 론 : 혈청 TPA-M과 Cyfra21-1은 폐암환자에 있어 CEA나 SCC보다 민감도와 특이도가 높으며 SCC의 경우 비소세포 폐암에 있어 높은 특이도를 보였으며 SCC의 측정치가 병기와 유관하게 나타났으나 종양의 크기와 병기의 진행과의 관계에 있어서는 더 많은 환자들을 대상으로 한 연구가 행해져야 할 것으로 생각된다.

  • PDF

3차원 입체조형치료에 의한 아교모세포종의 방사선 선량증가 연구 (Radiation Dose-escalation Trial for Glioblastomas with 3D-conformal Radiotherapy)

  • 조재호;이창걸;김경주;박진호;이세병;조삼주;심수정;윤덕현;장종희;김태곤;김동석;서창옥
    • Radiation Oncology Journal
    • /
    • 제22권4호
    • /
    • pp.237-246
    • /
    • 2004
  • 목적: 아교모세포종의 방사선치료에서 국소제어율과 생존율을 향상시켜 보고자 3차원 입체조형치료기법을 이용한 방사선선량 증가 연구를 전향적으로 시행하였다. 대상 및 방법: 1997년 1월부터 2002년 7월까지 아교모세포종으로 조직학적 진단이 되고 전신수행도(KPS)가 60 이상으로 수술 후 방사선치료를 받은 환자를 대상으로 하였다. 프로토콜에 따라 전향적으로 연구에 참여한 42예의 고선량군과 후향적 대조군인 33예의 저선량군을 비교 분석하였다 고선량군은 3차원 입체조형치료법에 의해 $63.0\~70.2$ Gy (중앙값 66 Gy)의 고선량 방사선을 조사받았으며, 저선량군은 2차원 치료방식으로 현재 표준선량으로 여겨지고 있는 59.4 Gy 정도(최소선량 50.4 Gy, 중앙선량 59.4 Gy)의 계획된 방사선치료를 종료할 수 있었던 환자들을 대상으로 하였다. 수술절제범위에 따라 나누어보면 전절제술 30예($40\%$), 준전절제술 30예($40\%$), 부분절제술 8예($11\%$), 그리고 조직생검만 시행된 환자가 7예($9\%$)였다. 각 환자의 육안종양체적은 CT 혹은 MRI상 수술절제연 및 잔류종양에 의해 정의되었다. 종양주변 부종은 저선량군에서는 임상표적체적에 포함되었지만, 고선량군에서는 재발양상 및 선량증가에 따른 합병증 증가의 가능성을 고려하여 제외하였다. 환자의 전체 및 무진행생존기간은 수술 받은 날을 기준으로 Kaplan-Meier법으로 산출하였고, 기존 문헌에 보고되고 있는 예후인자들과 각 환자에 조사된 방사선 선량, 표적체적 등이 생존율에 미치는 영향을 Log rank test 및 Cox regression analysis로 분석하였다. 추적관찰을 위해 정기적으로 MRI가 시행되었다. 결과: 전체환자의 중앙 생존기간 및 무진행 생존기간은 각각 $15{\pm}1.65$, $11{\pm}0.95$개월이었다. 중앙생존기간은 저선량군 및 고선량군이 각각 $14{\pm}0.94$개월, $21{\pm}5.03$개월로 고선량군에서 보다 나은 치료성적을 보여주었으며, 중앙무진행생존기간은 저선량군 $10{\pm}1.63$개월, 고선량군 $12{\pm}1.59$개월이었다. 특히 2년 생존율에 있어서 고선량군은 $44.7\%$$19.2\%$인 저선량군에 비해 훨씬 좋은 예후를 보였다. 단변량분석에서 예후에 영향을 미치는 중요인자로는 환자의 나이, 전신수행도, 종양의 위치, 수술절제범위, 표적체적, 방사선총선량 등이었다 다변량분석에서 통계적으로 유의한 인자는 환자의 나이(p=0.012), 수술절제범위(p=0.000), 방사선선량군(p=0.049)이었다. 방사선괴사와 같은 방사선으로 인한 직접적인 만성합병증은 추적관찰기간 동안 발생하지 않았다. 결론: 3차원 입체조형치료기법을 통하여 70 Gy까지의 방사선을 부작용 없이 조사할 수 있었고, 근치적 국소요법의 일환으로 방사선 선량증가가 전체 생존기간 및 무진행 생존기간을 향상시킬 수 있을 것으로 기대한다.

신생아 중환자실에 입원한 환아 어머니의 스트레스 (A Study on the Perceived Stress of Mothers in Neonatal Intensive Care Unit)

  • 최성희
    • Child Health Nursing Research
    • /
    • 제4권1호
    • /
    • pp.60-75
    • /
    • 1998
  • The parents have much expectation upon the pregnancy and child birth, and in most cases, they expect the healthy parturient child. However, we can be placed on the high-risk conditions which have the physical, social and immature infant, due to the unexpected results, among the new-born. Accordingly, these high-risk newborn and premature infants will be mostly in NICU, which the concentrated medical treatment can be given, upon their conditions. After their birth and during these periods, they will be divided from the parents, and the nurse will accomplish the bringing-up activities which they can take care of the infant, expected by the parents after their birth. The hospitalization of high-risk newborn including these premature infants is the shocking experience to the parents of family, and thus they can feel the fear and uneasiness, and these reactions of parents are troubled in the behavior at the usual days, and cause the disorder and spiritless status, and these results break the supporting ability of parents, and cause the obstruction. Also, the unavoidable division between the parents and the children as like hospitalization of children can make the parents to feel the alienation emotionally, and this causes the results which the pride on the bringing-up ability of baby gets to be lost. These problems can cause the difficulties on the bonding or the parenting in the further days, and can be related to the neglect and abuse of children. Also, it is gradually increased to study and report which the emotional division by the physical division between the mother and the baby obstructs the normal affection course between the parent and the infant. The stress caused by the birth and the hospitalization of high-risk newborn, as like this, is important in the points which it can uncertainly affect the potential energy for the relationship of parent-child who are finally healthy. Accordingly, the significance and purpose of this study are to understand the contents and degree of stress which the parents of high-risk newborn including the immature child can be experienced from the hospitalization of ICU for their new borns, and thus to offer the basic program to the nursing intervention program for these. The subject of this study is the mother of newborn in NICU of 10 General Hospitals located at the 3one of Pusan, Korea from September 1997 to October 1997, and thus makes the subject of 95 person of parents who agreed to take part in the study and it is descriptive study related to the stress of mother having the newborn in NICU. The method is based on the preceding study related to the stress of mother having the experience of child hospitalization and chronic disease child, and then acquires the advice of specialists group as like 5 nursing professors, and then is amended and supplemented. Total number of questions is 43 items and consists of 5 factors as like medical treatment &nursing procedures, disease status & prognosis, role of parents, communication & inter-personal relationships, hospital environment, and is 5 point Likert Scale. The reliability of this study method is very highly shown to be Cronbach α=0.95. The collected data is analysed as Average, Frequency, Standard Deviation, T-test, ANOVA, Pearson Correlation Coefficient, Duncan multifulrange test by use of SPSS /PC (V7.5). The results of this study is summarized as under. 1. Every characteristics of subject is which the party of mother is 28.70age(±7.48) in the average ages, 51% in the high-school graduate, 38.5% in the christianity, total monthly income is 212.55 thousand won(±1.971), 74.5% in the housewife, 72.9% in the parents and children together living and the number of children to be 1.48person(± 0.6) in average, the recognition on the prognosis of baby is 74.0% in 'Don't know', the relationship with the husband after the hospitalization of babyis 37.3% in 'More Intimate', the relationship with the family of husband to be 48% in 'No-change', and the degree which is consulted with the husband about the baby is 55% in 'very frequently' and the visiting number per week is 4.59(±1.63) in average and the accompanying person in the time of visiting is which the number of husband is 56.3% and thus is the highest. The characteristics of baby is which the age is 21.88days(±16.47) after the birth in average, the sex to be 50 person in the female 52.1% and the order of birth to be 54.2% in the first chid, and the weight in the birth to be 2770gm(±610) and the height in the birth to be 46.26cm(±7.62) in aver age. The medical diagnosis is 37.5% in the premature infant, the career of hospitalization is 96.9% in 'None', and the operation plan is 90.6% in 'None' and the execution of operation is 88% in 'None' and the nursing of incubator is 55.2% in 'Yes', and the method of feeding is 50.5% in 'Oral' and the contents of feeding is 46.9% in the 'Milk'. 2. The total stress degree of subject is almost highly shown to be as 3.36(±0.86). If it is compared upon each cause, 'stress on disease status & prognosis' is highest 3.79(±1.28), and it is in the order of 'stress on medical treatment & nursing procedures' 3.70(±0.93), 'stress on hospital environment' 3.14(±0.86), 'stress on role of parents' 3.18(±0.92) and 'stress on communication & inter personal relationship' 2.62(± 0.77) 3. As the results of checking the notworthiness of stress degree upon each variable of subject, the variable showing the noted difference was the birth weight(γ=-0.16, P=0.04), birth height(γ=-0.23, P=0.03), nursing in the incubator(F=8.93, P=0.04), feed method(F=2.94, P=0.04). That is to say, it is shown which the smaller the birth weight is, the higher the stress degree of mother is noteworthily. Also, the smaller the birth height baby is, the higher the stress of mother is. In the incubator, it os shown which the mother whose baby is nursing in the incubator is higher in the stress degree than other mothers. Upon the feeding method of baby, that is to say, TPNis the highest, and it is shown in the order of NPO, Tube feeding, and P.O. feeding. When we review the above-mentioned results, as the status is serious, it is thought which we include the supporting nursing for coping with the stress of parents in the setting-up od nursing plan for the baby in the NICU.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Clinical Characteristics of Chronic Cough in Korea

  • An, Tai Joon;Kim, Jin Woo;Choi, Eun Young;Jang, Seung Hun;Lee, Hwa Young;Kang, Hye Seon;Koo, Hyeon-Kyoung;Lee, Jong Min;Kim, Sung-Kyung;Shin, Jong-Wook;Park, So Young;Rhee, Chin Kook;Moon, Ji-Yong;Kim, Yee Hyung;Lee, Hyun;Kim, Yong Hyun;Kim, Je Hyeong;Lee, Sang Haak;Kim, Deog Kyeom;Yoo, Kwang Ha;Kim, Dong-Gyu;Jung, Ki-Suck;Kim, Hui Jung;Yoon, Hyoung Kyu;Cough Study Group of the Korean Academy of Tuberculosis and Respiratory Diseases
    • Tuberculosis and Respiratory Diseases
    • /
    • 제83권1호
    • /
    • pp.31-41
    • /
    • 2020
  • Background: Chronic cough is defined as a cough lasting more than 8 weeks and socio-economic burden of chronic cough is enormous. The characteristics of chronic cough in Korea are not well understood. The Korean Academy of Tuberculosis and Respiratory Diseases (KATRD) published guidelines on cough management in 2014. The current study evaluated the clinical characteristics of chronic cough in Korea and the efficacy of the KATRD guidelines. Methods: This was a multi-center, retrospective observational study conducted in Korea. The participants were over 18 years of age. They had coughs lasting more than 8 weeks. Subjects with current pulmonary diseases, smokers, exsmokers with more than 10 pack-years or who quit within the past 1 year, pregnant women, and users of cough-inducing medications were excluded. Evaluation and management of cough followed the KATRD cough-management guidelines. Results: Participants with chronic cough in Korea showed age in the late forties and cough duration of more than 1 year. Upper airway cough syndrome was the most common cause of cough, followed by cough-variant asthma (CVA). Gastro-esophageal reflux diseases and eosinophilic bronchitis were less frequently observed. Following the KATRD cough-management guidelines, 91.2% of the subjects improved after 4 weeks of treatment. Responders were younger, had a longer duration of cough, and an initial impression of CVA. In univariate and multivariate analyses, an initial impression of CVA was the only factor related to better treatment response. Conclusion: The causes of chronic cough in Korea differed from those reported in other countries. The current Korean guidelines proved efficient for treating Korean patients with chronic cough.

일 종합병원에서의 자문 현황과 5년 추이에 대한 고찰 (The Current Status and Changing Pattern for 5 Years of Psychiatric Consultation in a General Hospital)

  • 설장우;이상철;김현철;홍상의;이태병;이상규;김도훈;손봉기
    • 정신신체의학
    • /
    • 제13권2호
    • /
    • pp.75-84
    • /
    • 2005
  • 연구목적 : 종합병원 정신과 자문 실태와 변화양상(1997년과 2002년)을 조사하여 정신과 자문의 추이와 문제점에 대해 파악하고 대책과 발전 방향을 수립하고자 본 연구를 실시하였다. 방법: 1997년과 2002년에 입원하여 정신과로 자문 의뢰된 환자 347명, 317명에 대해서 자문결과지와 병록기록지를 참고하여 정신과 자문 현황을 조사, 비교, 분석하였다. 결과: 1) 자문 환자의 평균 연령이 45.9세(1997)에서 53.2세(2002)로 증가하였다. 40세 이하 집단이 감소한 반면 60세 이상의 환자군이 증가하였고, 특히 60세 이상 여성이 전체 여성환자 중 22.6%에서 48.5%로 두드러지게 증가하였다. 2) 전체 자문 의뢰율은 1997년 2.2%, 2002년 2.29%였다. 자문의뢰 건수는 내과가 각각 57.1%, 44.2%로 가장 많았고, 각 과별 자문율은 재활의학과가 두 해 모두 가장 높았다. 3) 정신과적 진단은 1997년에는 물질관련 장애가 17.3%로 가장 많았으나, 2002년에는 기분장애가 21.1%로 가장 많았다. 4) 자문의의 권고 사항은 약물사용 및 용량 조정에 관한 권유가 1997년 및 2002년 각 59.7%와 68.0%로 가장 높은 빈도를 보였다. 자문의가 제안한 약물의 종류는 1997년과 2002년 모두 항불안제가 가장 많았다. 2002년에는 Serotonin-specific reuptake inhibitors와 비전형적 항정신병 약물의 처방은 유의하게 증가되었고, 전형적 항정신병 약물의 사용은 유의하게 감소하였다. 결론: 1997년에 비해 2002년도의 자문현황은 자문환자의 연령이 증가하였고, 진단별로는 기분장애와 인지장애의 비율이 상대적으로 증가하였다. 약물권유는 잘 받아들여졌으나, 진단적 검사에 대한 관심은 떨어지는 편이었다.

  • PDF

소아 복부비만 진단을 위한 복부 전산화 단층 촬영의 유용성과 여러 지표와의 상관성 연구 (The Usefulness of the Abdominal Computerized Tomography for the Diagnosis of Childhood Obesity and Its Correlation with Various Parameters of Obesity)

  • 심윤희;조수진;유정현;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제48권10호
    • /
    • pp.1082-1089
    • /
    • 2005
  • 목 적 : 복부 비만은 고혈압, 인슐린 저항, 고인슐린혈증, 당뇨, 고지혈증과 같은 많은 심혈관계 질환의 위험 요인으로 제시되고 있다. 복부 비만을 측정하는 지표로 허리/둔부 비와 허리둘레가 사용되고 있으나, 관상동맥 질환의 예측인자로 복부 비만의 측정학적 cut-off 수치가 소아에서는 아직 제시되지 못하고 있다. 복부 전산화 단층촬영과 초음파를 이용하여 복부 지방을 측정하고, 여러 비만 지표들과의 상관관계를 연구함으로써 복부 비만의 합병증으로 초래되는 심혈관계 질환의 위험인자 평가 방법을 알아 보고자 본 연구를 실시하였다. 방 법 : 비만한 청소년 27명과 나이와 성별이 대등한 정상 체중을 가진 청소년 22명을 대상으로 하여 체질량 지수와 비만 지수, 상완둘레 및 삼각근에서 피부 두께를 비교하였다. 또한, 12시간 공복 상태에서 혈중 지질 및 혈당, 인슐린, 4가지 사이토카인을 측정하고, 인슐린 저항 지수를 구하였으며, 생체 전기저항법을 이용하여 체지방량, 체지방률, 복부지방률을 측정하여 비교하였다. 비만군에서는 복부 초음파로 배꼽부위 피하지방 두께와 복강 내 지방 두께를 측정하고, 복부 전산화 단층 촬영으로 얻은 횡단면 스캔에서 전체 지방 면적을 구하였고, 이 중 피하지방의 면적을 감산하여 복강 내 지방 면적을 구하였다. 결 과 : 소아에서 복부 CT로 측정한 총 지방 면적과 생체 전기 저항법으로 측정한 총지방량과 상관성이 매우 높았다(r=0.954, P<0.05). 복부 CT에서 측정한 복강 내 지방 면적은 상완둘레, 복부비만율, 초음파로 측정한 복부 내 지방 깊이 및 피하 지방량, 체질량 지수, 중성지방 등과 상관성이 높았다. 결 론 : 복부 CT는 복강 내 지방을 측정하는 가장 정확한 방법이지만 임상적으로 유용하지 못하므로, CT와 상관성이 높은 복부 초음파로 대치할 수 있다. 외래나 학교 신체검사에서 사용할 수 있는 선별 검사로는 생체 전기 저항법에 의한 체지방 측정, 상완 둘레, 체질량 지수, 허리/둔부 비 등이 있다. 소아 성인병의 심혈관 위험 예측 지표로는 공복시 leptin, 중성지방, 인슐린 농도 등을 사용할 수 있다.

주요 우울장애와 준임상적 우울증에서의 감정표현불능증 (Alexithymia in Major Depressive Disorder and Subclinical Depression)

  • 김석주;유승희;김성연;김동욱;조인희;조성진
    • 정신신체의학
    • /
    • 제15권2호
    • /
    • pp.100-106
    • /
    • 2007
  • 연구목적 : 본 연구는 주요 우울장애 환자들과 준임상적 우울증 환자들의 감정표현불능증 정도를 조사하기 위해 시행되었다. 방법 : 지역사회에 거주하는 386명(남/여=148/238, 평균 연령 : $43.0{\pm}13.9$, 연령 범위 : 19~79)이 연구에 참여했다. 구조화된 임상면담(Structured Clinical Inteview for DSM-IV, SCID)를 이용하여 주요 우울장애 및 기타 1축 정신질환을 진단했다. 우울증상를 평가하기 위해 역학연구센터 우울척도(the center for epidemiologic studies-depression scale, CES-D)를 자가 작성하게 했다. 감정표현불능증은 토론토 감정표현불능증 척도(Toronto alexithymia scale, TAS)로 평가했다. 주요 우울장애의 병력이 없는 이 중 SCID에서 경도 우울장애가 있거나, CES-D 점수가 16점 이상인 경우를 준임상적 우울증으로 정의했다. 주요 우울장애군, 준임상적 우울증군, 정상 대조군 세군으로 나누어 TAS 총점과 각 요인별 점수를 비교했다. 결과 : 전체 386명 중, 38명(9.8%)이 DSM-IV 주요 우울장애의 진단 기준에 부합하는 병력이 있었고, 57명(14.8%)이 준임상적 우울증군으로 분류되었다. 각 군간 TAS 총점($F_{2,383}=14.0$, p<0.01), 요인 1(감정인식의 장애) ($F_{2,383}=23.4$, p<0.01), 요인 2(감정표현의 장애)($F_{2,383}=7.8$, p<0.01)에 차이가 있었다. TAS 요인 3(외부지향적 사고)는 유의한 차이가 없었다($F_{2,383}=1.8$, p=0.16). 주요 우울장애군과 준임상적 우울증군은 모두 대조군에 비해 TAS 총점, 요인 1, 요인 2의 점수가 높았다(모두 p<0.01). 반면, 주요 우울장애군과 준임상적 우울증군은 TAS 총점 및 각 요인 점수에서 유의한 차이가 없었다. 결론 : 준임상적 우울증 환자는 우울증상이 없는 대조군에 비해 감정표현불능증이 더 심했다. 한편, 주요 우울장애와 준임상적 우울증은 감정표현불능증에서 유의한 차이가 없었다. 이러한 결과는 감정표현 불능증이 주요 우울장애 뿐아니라 준임상적 우울증과도 관계있음을 시사한다.

  • PDF

$TcpO_2$ 이용한 당뇨병성 신경병증 환자의 조기진단 (A new diagnostic method for diabetic neuropathy using $TcpO_2$)

  • 홍현기;김성우;남기창;차은종;김덕원
    • 전자공학회논문지SC
    • /
    • 제44권3호
    • /
    • pp.1-8
    • /
    • 2007
  • 당뇨병성 신경병증은 당뇨병성 신증, 당뇨병성 망막병증과 함께 당뇨병의 가장 흔한 합병증 중의 하나로 임상에서는 신경전도검사(nerve conduction velocity: NCV)를 실시하여 신경병증의 유무를 진단한다. 그러나 신경전도검사는 피부에 직접적으로 최대 100mA의 전기자극을 가하므로 피검자가 놀라거나 고통을 호소하는 경우가 많다. 본 논문에서는 $TcpO_2$를 이용하여 비관혈적으로 신경병증이 있는 그룹과 정상인 그룹 간의 $TcpO_2$$SpO_2$의 차이를 확인하고, $TcpO_2$$SpO_2$가 어떠한 관계인지 살펴보았다. 또한 $TcpO_2$ 측정방법을 당뇨병성 신경병증의 새로운 조기 진단 방법으로 제안하고자 하였다. 실험은 정상인 50명과 NCV를 통해 신경병증으로 확진 받은 당뇨병 환자 50명을 대상으로 하였으며, 분석 파라미터는 $TcpO_2$, $TcpCO_2$, $SpO_2$이었다. 측정결과 $TcpO_2$는 정상인과 당뇨병성 신경병증 환자 그룹 간에 손과 발에서 모두 통계적으로 유의한 차이가 있었다(p<0.01). $SpO_2$는 검지에서는 정상인과 당뇨병성 신경병증 환자 간에 통계적으로 차이가 없었지만(p>0.05), 엄지발가락에서는 유의한 차이가 있었다(p<0.01). 손가락의 $SpO_2$와 손의 $TcpO_2$는 상관관계가 0.400(p<0.01), 발가락의 $SpO_2$와 발의 $TcpO_2$는 0.471(p<0.01)로 통계적으로 유의한 상관관계를 발견하였다. 정상인과 당뇨병성 신경병증 환자 그룹 간에 손과 발의 $TcpO_2$ 방법의 민감도는 66%, 특이도는 92%로 나타났다. 본 연구를 통해서 $TcpO_2$ 방법이 신경병증의 유무를 확인할 수 있는 사전검사 도구로 사용이 가능할 수 있으며, 주기적인 $TcpO_2$ 검사를 통해 혈관폐색과 신경병증을 조기에 발견할 수 있어 당뇨병으로 인한 혈관폐색과 신경병증을 조기에 진단 할 수 있는 유용한 방법이 될 것으로 사료된다.