• Title/Summary/Keyword: Diagnosis Method

Search Result 4,991, Processing Time 0.032 seconds

A Diagnosis Algorithm for Hypercube Multiprocessors using Adaptive Cube Partition Method (적응적 큐브 분할을 이용한 하이퍼큐브 진단 알고리즘)

  • Choi, Moon-Ok;Rhee, Chung-Sei
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.4
    • /
    • pp.431-439
    • /
    • 2000
  • In this paper, we propose a system-level diagnosis algorithm for hypercube muti-processors using adaptive cube partition method. Feng[1] proposed a diagnosis algorithm for hypercube multiprocessors which gives a better performance compared to previous researches[2, 3]. But cube partitions in Feng's algorithm are performed without syndrome analysis. Therfore unnecessery overhead is made during cube partitions. In this paper, we propose an adaptive cube partition method which gives better partition through syndrome analysis and reduces diagnosis cost. We give a simulation result for comparisons. We have found that our algorithm shows better performance compared to Feng's method.

  • PDF

Spectrum Analysis of VHF/UHF PD in Simulated Transformer (모의 변압기의 VHF/UHF PD 스펙트럼 분석)

  • Kim, Duck-Keun;Kim, Jong-Seo;Lim, Yong-Bae;Lim, Jang-Seob;Moon, Chae-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.50-54
    • /
    • 2000
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

Fault Diagnosis of Roll Shape Under the Speed Variation in Hot Rolling Mill

  • Lee, Chang-Woo;Kang, Hyun-Kyoo;Shin, Kee-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.9
    • /
    • pp.1410-1417
    • /
    • 2006
  • The metal processing system usually consists of various components such like motors, work rolls, backup rolls, idle rolls, sensors, etc. Even a simple fault in a single component in the system may cause a serious damage on the final product. It is therefore necessary to diagnose the faults of the components to detect and prevent system failure. Especially, the defects in a work roll are critical to the quality of strip. It is especially difficult to detect faults of a roll by using the existing frequency analysis method if the speed of the roll is changing. In this study, a new diagnosis method for roll eccentricity under the roll speed changes was developed. The new method was induced from analyzing the rolling mechanism by using rolling force models, radius-speed relationship, and measured rolling force, etc. Simulation results by using the field data show that the proposed method is very useful.

Comparison of acridine orange and giemsa stains for malaria diagnosis (말라리아 진단을 위한 Acridine Orange 염색법과 Giemsa 염색법의 효율성 비교)

  • 공현희;정동일
    • Parasites, Hosts and Diseases
    • /
    • v.33 no.4
    • /
    • pp.391-394
    • /
    • 1995
  • Recently, the Acridine orange (AO) staining method has improved for identification of malaria parasites. Fixed and preserved blood smears of malaria patients were used for comparative analysis of AO and Giemsa stains. The AO staining method required less time and was more sensitive under lower magnification than the Giemsa staining method . The AO staining method provides an alternative to Giemsa for malaria diagnosis in the field and laboratory.

  • PDF

The Application of IRR-Camera for the Diagnosis of Surface Degradation (표면열화진단을 위한 적외선카메라의 응용)

  • Lim, Jang-Seob;Jeong, Seung-Chun;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.61-65
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

Frequency Analysis Method Based Fault Diagnosis of an Electrolytic Capacitor for Voltage Smoothing (주파수 분석기법을 이용한 전압 평활용 전해 커패시터의 고장진단)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.207-213
    • /
    • 2009
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. This paper proposed a novel fault diagnosis method of an electrolytic capacitor used for voltage smoothing in boost DC converter. The equivalent series resistance(ESR) of electrolytic capacitor estimated from FFT result of filtered waveform of capacitor voltage/current. Main advantage of the proposed method include circuit simplicity and easy implementation. Simulation and experimental results are shown to verify the performance of the proposed method.

The New Aging Diagnosis in IEC-60587 (IEC-60587의 새로운 열화진단)

  • Lim, Jang-Seob;Chung, Seung-Chun;Jeong, Jong-Cheol;Park, Gye-Choon;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.71-74
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used In surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms (태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

Model-based Fault Diagnosis Applied to Vibration Data (진동데이터 적용 모델기반 이상진단)

  • Yang, Ji-Hyuk;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.12
    • /
    • pp.1090-1095
    • /
    • 2012
  • In this paper, we propose a model-based fault diagnosis method applied to vibration data. The fault detection is performed by comparing estimated parameters with normal parameters and deciding if the observed changes can be explained satisfactorily in terms of noise or undermodelling. The key feature of this method is that it accounts for the effects of noise and model mismatch. And we aslo design a classifier for the fault isolation by applying the multiclass SVM (Support Vector Machine) to the estimated parameters. The proposed fault detection and isolation methods are applied to an engine vibration data to show a good performance. The proposed fault detection method is compared with a signal-based fault detection method through a performance analysis.

A Study on the Real-Time Switch Fault Diagnosis of the Power conditioning System (전력변환 시스템의 실시간 스위치 고장진단에 대한 연구)

  • Lee, Yong-Sik;Lee, Sun-Woo;Gim, Jae-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1066-1067
    • /
    • 2015
  • This paper presents a diagnosis method for the detection and location of open-short switch faults in the three-phase power conditioning system. A method for switch fault diagnosis on the power conditioning system is proposed, based on the concordia transform. The switch fault types and locations on power conditioning system are diagnosed by a method in which analyze the d-q current vector locus and current pattern. The Simulation results confirm the proposed diagnostic method.

  • PDF