• Title/Summary/Keyword: Diagnosis Instrument

Search Result 191, Processing Time 0.029 seconds

Implementing Graphic User Interface System for Microwave Radiometry Data to Utilize Breast Cancer Diagnosis (유방암 진단 활용을 위한 마이크로파 라디오미터 측정 데이터의 GUI 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Jeong-Whan;Han, Jong-Sam;Heo, Kyou-Hak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.6
    • /
    • pp.818-824
    • /
    • 2013
  • In this study, a novel Graphic User Interface (GUI) software development system is suggested so that it can be applied to diagnose breast cancer with utilizing 3~4.2 GHz microwave radiometric data. The estimated inner and surface temperature values on the patient's right and left breast in terms of microwave radiometry are visualized in HSV color mapping space and their relevant contour regions and lines are depicted by Marching Square graphic algorithm. Also the database system is implemented in terms of patient and diagnostic module to support the medical decisions concerning the breast cancer diagnosis.

A Study on the Diagnosis for Water Absorption of Generator Stator Windings (발전기 고정자 권선의 흡습 진단)

  • Bae Y.C.;Kim H.S.;Lee D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

Fuzzy-Bayes Fault Isolator Design for BLDC Motor Fault Diagnosis

  • Suh, Suhk-Hoon
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.354-361
    • /
    • 2004
  • To improve fault isolation performance of the Bayes isolator, this paper proposes the Fuzzy-Bayes isolator, which uses the Fuzzy-Bayes classifier as a fault isolator. The Fuzzy-Bayes classifier is composed of the Bayes classifier and weighting factor, which is determined by fuzzy inference logic. The Mahalanobis distance derivative is mapped to the weighting factor by fuzzy inference logic. The Fuzzy-Bayes fault isolator is designed for the BLDC motor fault diagnosis system. Fault isolation performance is evaluated by the experiments. The research results indicate that the Fuzzy-Bayes fault isolator improves fault isolation performance and that it can reduce the transition region chattering that is occurred when the fault is injected. In the experiment, chattering is reduced by about half that of the Bayes classifier's.

Diagnostic Values of Tongue Coating Thickness and Sterno-costal Angle in Functional Dyspepsia (기능성 소화불량 환자에서 설태후박 및 흉늑각 측정의 진단적 가치)

  • Son, Ji-Young;Kim, Jin-Sung
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.157-174
    • /
    • 2014
  • Objectives : The aims of this study were to evaluate the diagnostic values of tongue coating thickness and sterno-costal angle as the quantitative diagnostic indicators in functional dyspepsia. Methods : We surveyed 60 functional dyspepsia patients recruited by the clinical trial, 'Clinical Trial for Evaluation on Availability of tongue diagnosis system (CTS-1000) : a Pilot study'. The patients were classified into three groups according to Rome III criteria for functional dyspepsia, and categorized into five groups according to Instrument of pattern identification for functional dyspepsia. Nepean dyspepsia index-Korean version (NDI-K) score, tongue coating thickness (percentage of tongue coating by tongue diagnosis system (CTS-1000), and weight of tongue coating by microbalance), sterno-costal angle, duration of illness and body mass index (BMI) were investigated. Results : Among the 5 types by instrument of pattern identification for functional dyspepsia, a significant difference of percentage of tongue coating was found. Percentage of tongue coating and weight of tongue coating showed significant correlation with total NDI-K score. Sterno-costal angle showed strong positive correlation with BMI and also showed significant difference between the non-overweight (BMI<23, n=32) and overweight ($BMI{\geq}23$, n=28) groups. Conclusions : Tongue coating thickness showed its potential as a new quantitative diagnostic indicator of functional dyspepsia. Further studies on the sterno-costal angle are anticipated to evaluate its potential as a new quantitative diagnostic indicator.

Development of Glioblastoma In Vivo Model for the Research of Brain Cancer Diagnosis and Therapy (뇌암 진단 및 치료 연구를 위한 교모세포종 동물모델 개발)

  • Kang, Seonghee;Kang, Bosun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.389-395
    • /
    • 2014
  • The research was carried out to develop a animal model of malignant brain tumor for the researches in glioblastoma multiform (GBM) diagnosis and therapy. C6 cells were transplanted into the right striatum of SD rat using stereotactic instrument for the development. The developed animal model was verified by MRI and H&E stain assay of anatomicohistological examination. The MRI observations showed that the tumor developed at the injection site at the 7 days after glioblastoma inoculation. At 14 days post inoculation, the tumor grew to a large volume occupying almost a half of the right cerebral hemisphere. It was confirmed that the expression of excessive mitosis and pleomorphism in anatomicohistological examination. The developed animal model must be necessary and useful tool for the in vivo level research in the development of the new modality for the diagnosis and therapy of brain cancer.

Reliability of the Korean Version of Tampa Scale for Kinesiophobia for Temporomandibular Disorders

  • Park, In Hee;Jang, Ji Hee;Chung, Jin Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.43 no.2
    • /
    • pp.34-40
    • /
    • 2018
  • Purpose: The aim of this study was to translate the original English version of tampa scale for kinesiophobia for temporomandibular disorders (TSK-TMDs) for cultural equivalency into Korean language and to evaluate the reliability of the Korean version of the TSK-TMD among symptom free subjects. Methods: The original version of TSK-TMD was translated and cross-culturally adapted following international guidelines. A total 90 subjects (50 women, 40 men) were participated to fill out the questionnaire. The internal consistency and test-retest reliability with a one- or two-week time interval were evaluated. Results: The internal consistency of TSK-TMD of the original and the modified 12-item TSK-TMD were 0.866, and 0.858, respectively using the Cronbach's alpha coefficient. And the internal consistency of activity avoidance (AA) and somatic focus (SF) subscale were 0.838 and 0.807 assessed with Cronbach's alpha indicating excellent reliability. Test-retest reliability of the original TSK-TMD measured by the intra-class correlation coefficient (ICC) was 0.764, and coefficients value of the 12-question TSK-TMD was 0.752. Test-retest reliability of AA subscale was 0.722 and SF subscale was 0.677 measured by ICC. Conclusions: The Korean version of the TSK-TMD questionnaire was found to be a reliable instrument and successfully translated to Korean language. There are no significant differences between overall and modified version of TSK-TMD. It can be used as a valuable instrument for the analyses of the psychosocial aspects of the TMD patients in Korea.

Design of Oriental Medicine diagnosis system by Bio-Electric Response (생체-전기적 반응에 의한 한의학적 진단시스템의 설계)

  • 이용흠;장근중;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.420-429
    • /
    • 2004
  • It has been needed diagnosis technology of the EFG(Electro Functio Gram) measurement concept which is incorporated characteristic of modern science and biomedical engineering, because function abnormality diagnosis can't diagnose with visualization instruments or clinical pathology. The general diagnosis system(EFG system) has been developed to use basic diagnosis instrument that has reappearance, reliance and convenience using the functio diagnosis technology, in the field of western/oriental medicine. Also, we improved sticking electrode and simultaneous measurement method of the limbs 8CH, head 2CH to diagnose body circulation of Qi and acupoints for Oriental Medicine diagnosis/therapy. The result of clinical for adult man 20 persons, the EFG system can diagnose state of 12 meridians and autonomic nervous system. Therefore, in this paper, we designed of oriental medicine diagnosis system by bio-electric response with materialized H/W and S/W for 12 meridians state diagnosis of human body and system construction of the EFG.

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Turbine discharge measurement case study using ASFM system (ASFM을 이용한 수차유량의 측정)

  • Kim, Eung-Tae;Jeong, Yong-Chea;Park, Jang-Won
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.49-52
    • /
    • 2006
  • should be in English, A make out an economical, reliable and easy to adoptable instrument in turbine discharge measurement was restricted from lots of it's foundational condition. Not with standing the brilliant progress in new technology of these day, useful instrument for flow measurement in turbine is still ongoing. Nowaday, the increasing importance of renewable energy makes it more important that the measuring turbine efficiency as a decision making index of old turbines' replacement. In Turbine performance diagnosis, Kwater(Korea Water Corporation) got an enough ability and decent reputation for who has invested lots of time and effort for buildup and development. In Korea as a public corporation who should take a crucial roll in Turbine business, Kwater has introduced some developed new technology for other domestic concerned one. With this writing, I'd like to introduce ASFM system as a newly developed instrument that can cope with lots restriction in discharge measurement in turbine. Kwater adopted the system in 2005, and performed 2 times of trial test. The test result was good enough to use the system as a reference test method.

  • PDF

The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI (BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF