• 제목/요약/키워드: Dew formation

검색결과 31건 처리시간 0.027초

Distribution and Changes in Occurrence of Fingerprint Stem Blight of Eleocharis kuroguwai Caused by Epicoccosorus nematosporus in Korea

  • Hong, Yeon-Kyu;Ryu, Kil-Lim;Hyun, Jong-Nae;Uhm, Jae-Youl;Kim, Soon-Chul
    • The Plant Pathology Journal
    • /
    • 제18권3호
    • /
    • pp.152-155
    • /
    • 2002
  • Epicoccosorus nematosporus was detected in all 22 counties surveyed, but the frequency of occurrence of fingerprint stem blight disease (FSBD) on Eleocharis kuroguwai caused by the fungus varied with fields and regions. The disease occurred more frequently in mountain areas than in plain areas. E. nematosporus was detected in less than 20% of plain areas such as Cimjae and Milyang, whereas, it occurred in 40-60% of mountain areas such as Sangiu and Jangsoo. In Milyang, mean temperature in July to August 1993 ranged from 17 to $27^{\circ}C$ with 14.3 h of dew period. Meanwhile, in the mountain area such as Sangiu, Gyeongbook, temperature ranged from 17 to $24^{\circ}C$ with 16.1 h of dew period. Plant mortality was 61% in Milyang and 82% in Sangju. Underground tuber formation was highly suppressed at 16 and 33 tubers per plot in Sangju and Milyang, respectively. In 1992 and 1995, plants infected ranged from 40 to 78% in July to September. This sharply decreased to an average of 15% in 1999.

지역난방 첨두부하보일러 대류부 부식 파손 분석 (Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler)

  • 김영수;채호병;홍민기;송민지;조정민;김우철;하태백;이수열
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

한국남서연안해역의 저수온 출현과 안개 형성과의 관련성에 관한 연구 (A Study on Relationship between Cold Water Appearance and Fog Formation in the Southwest Coastal Waters of Korea)

  • 윤종휘;정희동;조규대;이충일
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2004년도 추계학술발표회
    • /
    • pp.123-127
    • /
    • 2004
  • It is known that cold water appears and fog frequently forms in the southwest coastal waters of Korea in summer. The authors investigate the time and place. of cold water existence, and also whether the cold water affects the occurrence of fog formation. As a result, cold water begins to appear around Daeheugsando at the early summer. It gets colder with times and cold water area moves toward southwest of Jindo in mid-summer, then disappears in this area around mid-Oct. Fog mostly forms in April through August and most frequently occurs at Chukdo(Jindo) where sea surface temperature shows lower than that at the adjacent area. Accordingly it is taken that the cold water is considerably contributed to form the dense and frequent fog around Jindo area.

  • PDF

Influence of Selective Oxidation Phenomena in CGLs on Galvanized Coating Defects Formation

  • Gong, Y.F.;Birosca, S.;Kim, Han S.;De Cooman, B.C.
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.1-5
    • /
    • 2008
  • The gas atmosphere in continuous annealing and galvanizing lines alters both composition and microstructure of the surface and sub-surface of sheet steel. The formation and morphology of the oxides of alloying elements in High Strength Interstitial Free (HS-IF), Dual Phase (DP) and Transformation-Induced Plasticity (TRIP) steels are strongly influenced by the furnace dew point, and the presence of specific oxide may result in surface defects and bare areas on galvanized sheet products. The present contribution reviews the progress made recently in understanding the selective formation of surface and subsurface oxides during annealing in hot dip galvanizing and conventional continuous annealing lines. It is believed that the surface and sub-surface composition and microstructure have a pronounced influence on galvanized sheet product surface quality. In the present study, it is shown that the understanding of the relevant phenomena requires a combination of precise laboratory-scale simulations of the relevant technological processes and the use of advanced surface analytical tools.

Inconel 625 용사코팅된 절탄기 핀튜브의 전기화학적 내식성 분석 (Analysis of Electrochemical Corrosion Resistance of Inconel 625 Thermal Spray Coated Fin Tube of Economizer)

  • 박일초;한민수
    • 해양환경안전학회지
    • /
    • 제27권1호
    • /
    • pp.187-192
    • /
    • 2021
  • 본 연구는 절탄기 튜브의 저온부식 손상을 방지하기 위해 Inconel 625 용사재료를 활용하여 아크 열용사 코팅기술 적용 후 실링처리를 실시하였다. 용사코팅(TSC) 층의 내식성 분석을 위해 0.5 wt% 황산 수용액에서 다양한 전기화학적 실험을 진행하였다. 양극분극 실험 후에는 주사전자현미경과 EDS 성분분석을 통해 부식 손상 정도를 파악하였다. 자연전위 계측 시 TSC+실링처리(TSC+Sealing)의 안정적인 전위 형성을 통해 실링처리 효과를 확인하였다. 양극분극 실험 결과 TSC와 TSC+Sealing에서 부동태 영역이 확인되었으며, 부식 손상 역시 관찰되지 않아 내식성이 개선되었다. 더불어 타펠분석에 의해 산출된 부식전위와 부식전류밀도 분석 결과 TSC+Sealing의 내식성이 가장 우수하게 나타났다.

국지풍이 내륙의 안개발생에 미치는 영향 (Influence of Local Wind on Occurrence of Fog at Inland Areas)

  • 심화남;이영희
    • 대기
    • /
    • 제27권2호
    • /
    • pp.213-224
    • /
    • 2017
  • We have examined the influence of local wind on occurrence of fog at two inland areas, Chuncheon and Andong, in Korea. The surrounding topography of two inland areas shows significant difference: Chuncheon is located in the basin surrounded by ridges with north-south axis while Andong is located in the valley between the ridges with east-west axis. Occurrence of fog shows maximum in October at both sites but high occurrence of fog at Chuncheon is also noted in the winter. Occurrence of fog at Andong in October is much larger than that at Chuncheon. High occurrence of fog in October is due to favorable synoptic condition for fog formation such as weak wind, clear day and small depression of the dew-point. Fog occurrence at Chuncheon is closely related to very weak wind condition where wind speed is less than $0.5m\;s^{-1}$. The weak wind at Chuncheon in winter is due that pressure driven channeling wind (southerly) cancels out partly downslope northerly flow during nighttime. On the other hand, fog at Andong occurs well when wind is southeasterly which is thermally forced flow during nighttime. Southeasterly provides cold, moist air from the narrow valley to Andong during nighttime, leading to favorable condition for formation of fog.

알루미나 소결체와 금속간의 접합에 관한 연구 (The Study of Alumina Ceramic to Metal Bonding)

  • 김종희;김형준
    • 한국세라믹학회지
    • /
    • 제15권2호
    • /
    • pp.89-97
    • /
    • 1978
  • The basic mechanism of adherence in sintered high purity alumina ceramic-to-metal bonding was studied. Emphasis was placed on flux composition, porosity of the fired ceramics, and metallizing mixtures. The study was conducted on 95 and 99.5% alumina, using molydbenum-manganese, molybdenum-manganese-silicon dioxide metallizing compositions. Metallizing was performed in wet hydrogen (dew point, +17$^{\circ}C$) at 145$0^{\circ}C$ for 45min. This experiment indicated that adhernece mechanism of ultra high purity alumina ceramic was attributed to formation of $MnAl_2O_$4, and in the case of 95% alumina containing glass, the migration of glass from the interface into the void of the metal coating was the main role to the adhrence. It showed also that greater the bond-strength was resulted as porosity was increased.

  • PDF

수평 실린더 표면의 착상에 대한 실험적 연구 (An Experimental Study of Frost Formation on the Horizontal Cylinder)

  • 백상진;이윤빈;노승탁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.240-245
    • /
    • 2000
  • In this study, thickness, density and effective thermal conductivity of frost forming on the horizontal cylinder were measured with various air temperature and humidity. Reynolds number and temperature of cooling surface are controlled 17300 and $-l5^{\circ}C$ respectively. In each case of air temperature $5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C,$ varying absolute humidity, experiments were executed. In measuring frost surface temperature and thickness of frost layer, infrared thermocouples and CCD camera were used. Frost was gathered from cylinder to measure mass of frost layer. Experimental data showed that the thickness and effective thermal conductivity of the frost layer increase with respect to time. Thickness of frost layer increase with humidity increasing, and density of frost layer increase with air temperature rising. Frost growth with air temperature and density of frost layer with humidity are affected by whether dew point is below or above freezing point.

  • PDF

환경열화에 의한 가선재의 피로거동 (Fatigue Behavior of Catenary Wires by Environments Degradation)

  • 김용기;장세기
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.14-19
    • /
    • 2004
  • The effect of surface damage on fatigue properties of catenary wires were investigated to estimate their service lift. As surface defects of the wires caused by surface corrosion increase, surface roughness gets worse, and as roughness increases, it is easy for moisture coming from rain and dew to be condensed around uneven parts of the surface. The condensed moisture causes a locally severe corrosion which leads to damage of the wires. Corrosion of catenaty wires can make their actual lifetime shorter than that originally designed. The amount of decrease was more prominent as environmental conditions became more corrosive. They are also vibrated with some amplitude everytime pantographs touch contact line. The frequent cyclic load on the wire may result in a fatigue fracture. Surface damage by corrosion can make formation of crack initiation at fatigue. In the present study, the fatigue life of the used wire was measured 35 to 50% compared with that of new one in average.

한국 남서연안해역의 저수온 출현과 안개 형성과의 관련성에 관한 연구 (A Study on Relationship between Cold Water Appearance and Fog Formation in the Southwest Coastal Waters of Korea)

  • 윤종휘;정희동;조규대;김동선;이은방
    • 한국항해항만학회지
    • /
    • 제29권6호
    • /
    • pp.583-588
    • /
    • 2005
  • 하계 한국 남서연안 해역에는 저온수가 나타나고 안개가 자주 형성되는 것으로 알려져 있다. 본 연구에서는 저온수의 출현시기 및 장소와 이 해역에서 형성되는 안개에 미치는 저온수의 영향에 대해 조사${\cdot}$분석하였다. 그 결과, 저수온역은 초여름 대흑산도 부근해역에서 나타나기 시작하여, 이것은 점차 이동하여 7월 말${\~}$8월 초 진도 남서쪽 해역에 위치하고, 그 후 10월 중순경 이 해역에서 소멸된다. 그리고 이 해역에서는 주로 4${\~}$8월에 안개가 발생하는데, 특히 인근해역에 비해 해면온도가 현저하게 낮은 진도해역에서 안개 발생빈도가 높은 것으로 보아, 이 해역에 나타나는 저온수가 안개의 형성에 상당한 영향을 끼치는 것으로 사료된다.