• Title/Summary/Keyword: Dew Point

Search Result 192, Processing Time 0.026 seconds

담수직파 벼의 신장기 군락내 미기후 특성 (Canopy Microclimate of Water-Seeding Rice during Internode Elongation Period)

  • 윤진일;신진철;윤용대;박은우;조성인;황헌
    • 한국작물학회지
    • /
    • 제42권4호
    • /
    • pp.473-482
    • /
    • 1997
  • Temperature, humidity and wetness duration were monitored for fully developed paddy rice canopies with 3 different structures induced by the seeding method(puddled-soil drill seeding, DS ; hand broadcasting, HB ; machine broadcasting, MB). Within-canopy air temperature averaged over "clear sky" hours during the study period(maximum tillering through heading) was lower than the screen temperature at a nearby standard weather station, especially in the night. The same trend was true for "overcast sky" hours except the diurnal distinction. Vapor pressure within the canopy was high during the daytime and low in the night, making the daytime deviation from outside the canopy more significant on clear days. Under the overcast sky, the canopy maintained a steady 5 to 10% higher vapor pressure than the outside regardless of day or night. Daily maximum temperature was observed to be higher within the canopies with more leaf mass, making MB the highest, HB the lowest, and DS in between. Relative humidity was over 90% in the night and dropped to 70% in the mid-afternoon, but vapor pressure within the canopy was highest at around 13:00 LST. Dew point depression was lowest and, combined with the temperature, the relative humidity was highest in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.

  • PDF

기상청 현업 모형(UM)과 1차원 난류모형(PAFOG)의 접합시스템 개발 및 검증 (Development and Validation of the Coupled System of Unified Model (UM) and PArameterized FOG (PAFOG))

  • 김원흥;염성수
    • 대기
    • /
    • 제25권1호
    • /
    • pp.149-154
    • /
    • 2015
  • As an attempt to improve fog predictability at Incheon International Airport (IIA) we couple the 3D weather forecasting model currently operational in Korea Meteorological Administration (regional Unified Model, UM_RE) with a 1D turbulence model (PAFOG). The coupling is done by extracting the meteorological data from the 3D model and properly inserting them in the PAFOG model as initial conditions and external forcing. The initial conditions include surface temperature, 2 m temperature and dew point temperature, geostrophic wind at 850 hPa and vertical profiles of temperature and dew point temperature. Moisture and temperature advections are included as external forcing and updated every hr. To validate the performance of the coupled system, simulation results of the coupled system are compared to those of the 3D model alone for the 22 sea fog cases observed over the Yellow Sea. Three statistical indices, i.e., Root Mean Square Error (RMSE), linear correlation coefficient (R) and Critical Success Index (CSI), are examined, and they all indicate that the coupled system performs better than the 3D model alone. These are certainly promising results but more improvement is required before the coupled system can actually be used as an operational fog forecasting model. For the RMSE, R, and CSI values for the coupled system are still not good enough for operational fog forecast.

이슬점 응축 현상을 이용한 오일 내 수분함량 측정에 관한 실험적 연구 (An Experimental Study on the Measurement of Water Content in an Lubricating Oil by Implementing a Dew-point Condensation Sensor)

  • 공호성;윤의성;한흥구;김학열
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.130-136
    • /
    • 2004
  • Presence of water in the lubricating oils could be one of the first indicators of potentially expensive and possibly catastrophic failure of the machine as it may cause displace the oil films to prevent the lubrication function of the oil or chemically react with many oil additives resulting in the oil degradation. In order to detect water content quantitatively in lubricating oils many methods and sensors has been developed. Among these, capacitive sensors including sensitive layer, whose dielectric factor changes according to the water content absorbed in the layer, are proposed mainly in the market. But these sensors are not sensitive to a high water content. Besides, the absorbing layer soils in time. In this work, an evaporation of water moisture from oil into air volume above lubricant surface and condensation of water vapor at a cooling surface was used to measure water content quantitatively in an lubricating oil. Laboratory test results of a prototype sensor were presented. Test results showed that the proposed method could be avaliable to measure a low levels of oil moisture.

  • PDF

흡착제로서 숯의 이용 가능성에 대한 연구 (A study of the Possibility of the Charcoal as Desiccant)

  • 김종열
    • 수산해양교육연구
    • /
    • 제26권5호
    • /
    • pp.1083-1089
    • /
    • 2014
  • The aims of this study are to find out the possibility of the charcoal as a desiccant. The only humidity control under high temperature and high humidity environment can be provided to the thermal comfort at indoor environment. Functionality of charcoal is known to be deodorization, antiseptic effect, filtering effect and humidity control. But research related to humidity control in the country not yet. Thus, the dehumidification capacity of the charcoal experimental results to see the results were as follows : 1) Entering the experimental humidification is 148.02 g/h, 161.05 g/h and 243.2 g/h when air velocity was changed 1.5 m/s, 1.7 m/s and 2.0 m/s. 2) When the basis weight of the charcoal 2.0 m/s air velocity to obtain the largest number of adsorption capacity. 3) Dru bulb temperature and dew point temperature ware measured at front and rear of the charcoal. Absolute humidity is calculated from the measured Dry bulb temperature and dew point temperature. The quantity of dehumidification is calculated from absolute humidity is the largest 129.6 g/h at the air velocity 2.0 m/s.

Effect of Annealed Oxides on the Formation of Inhibition Layer During Hot-Dip Galvanizing of 590Mpa Trip Steel

  • Kim, Seong-Hwan;Huh, Joo-Youl;Lee, Suk-Kyu;Park, Rho-Bum;Kim, Jong-Sang
    • Corrosion Science and Technology
    • /
    • 제10권1호
    • /
    • pp.6-12
    • /
    • 2011
  • The selective surface oxidation of a transformation-induced-plasticity (TRIP) steel containing 1.6 wt.% Mn and 1.5 wt.% Si during annealing at $800^{\circ}C$ was investigated for its influence on the formation of an inhibition layer during hot-dip galvanizing. The selective oxidation of the alloying elements and the oxide morphology were significantly influenced by the annealing atmosphere. The pure $N_{2}$ atmosphere with a dew point $-40^{\circ}C$ promoted the selective oxidation of Mn as a crystalline $Mn_{2}SiO_{4}$ phase, whereas the $N_{2}$ + 10% $H_{2}$ atmosphere with the same dew point $-40^{\circ}C$ promoted the selective oxidation of Si as an amorphous Si-rich oxide phase. During hot-dip galvanizing, the $Mn_{2}SiO_{4}$ phase was reduced more readily by Al in the Zn bath than the Si-rich oxide phase. Consequently, the pure $N_{2}$ atmosphere resulted in a higher formation rate of $Fe_{2}Al_{5}$ particles at the Zn/steel interface and better galvanizability than the $N_{2}$ + 10% $H_{2}$ atmosphere.

춘천지방에서 발생한 안개 특성 분석 (Climatological Analysis of Fog Occurrence at Chuncheon)

  • 백승주;이귀옥;임헌호;이화운
    • 한국환경과학회지
    • /
    • 제16권5호
    • /
    • pp.583-591
    • /
    • 2007
  • In this study, meteorological characteristics concerning the occurrence of fog are analyzed using 4-years (2000-2003) data at Chuncheon. From the analysis of meteorological characteristics, the fog at Chuncheon occurred before sunrise time and disappeared after that time and lasted for 2-4 hours. When fog occurred, on the whole, wind direction was blew the northerly and wind speed was below 2.1 m/s. Especially, about 42 % of foggy day fell on the calm($0{\sim}0.2m/s$) conditions. The difference between air temperature and dew point temperature near the surface were mainly less than $2^{\circ}C$. For the lack of water surface temperature, the water sur-face temperature was calculated by using Water Quality River Reservoir System (WQRRS). In Chuncheon, there is close correlation between the frequency of fog day and outflow from Soyang reservoir and high frequency of occurrence due to the difference between air and cold outlet water temperature.

초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정 (Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building)

  • 김민휘;김진효;권오현;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

Theoretical and Experimental Considerations of Thermal Humidity Characteristics

  • Choi, Seok-Weon;Cho, Ju-Hyeong;Seo, Hee-Jun;Lee, Sang-Seol
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제3권1호
    • /
    • pp.9-18
    • /
    • 2002
  • Thermal humidity characteristics were considered theoretically and experimentally. A Simply well-fitted correlation of a saturated vapor pressure-temperature curve of water was introduced based on Antoine equation to make theoretical prediction of relative humidity according to temperature variation. Characteristics of dew point were also examined theoretically and its relation with temperature and humidity was evaluated. The exact mass of water vapor in a specified humidity and temperature condition was estimated to provide useful insight into the idea about how much amount of water corresponds to a specified humidity and temperature condition in a confined system. A simple but well-fitting model of dehumidification process was introduced to anticipate the trend of relative humidity level during GN2(gaseous nitrogen) purge process in a humidity chamber. Well-suitedness of this model was also verified by comparison with experimental data. The overall appearance and specification of two thermal humidity chambers were introduced which were used to perform various thermal humidity tests in order to yield useful data necessary to support validity of theoretical models.

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

서해 연안 해역에서의 조석현상이 안개에 미치는 영향 (Impact of Tidal Effects on Fog Events in the Western Coast of Korea)

  • 안혜연;정주희;김유근
    • 한국환경과학회지
    • /
    • 제30권11호
    • /
    • pp.925-936
    • /
    • 2021
  • The study was aimed to investigate the correlation between tidal effects and fog occurrence in Incheon and Mokpo, which are located in the middle and southern coasts of the West Sea of Korea, respectively. The investigation used meteorological data obtained from the automated synoptic observing systems and automatic weather stations and ocean data from tide stations from 2010 to 2019. Fog occurrence frequency was highest at high tide (Incheon, 41%; Mokpo, 45%). During fog event days at high tide, the dew-point depression was low (Incheon, 0.5℃; Mokpo, 0.4℃) and the relative humidity was high (Incheon, 97%; Mokpo, 98%). The wind speed was 2.4 m/s in Incheon and 2.0 m/s in Mokpo, and the main wind directions were west-southwesterly from Incheon and southwesterly from Mokpo. In the fog case study, tidal flats were covered with water before and after the fog started. During the fog period, both stations experienced negative air-sea temperature differences, low dew-point depression, and high relative humidity were maintained, with weak winds forming from the tidal flats to the shore.