• Title/Summary/Keyword: Dew

Search Result 314, Processing Time 0.028 seconds

A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings (공동주택 세대내 결로방지 설계를 위한 실내외 온습도 기준 수립 연구)

  • Hwang, Ha-Jin;Kim, Jong-Yeop;Lee, Jong-Sung
    • Land and Housing Review
    • /
    • v.2 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • Recently, the chance of dew condensation in apartment buildings is increasing because of several reasons. For example, ventilation rate has been decreased because of high-insulations and airtightness for saving energy. Besides, the humidity has been made by drying washes, cooking and bathing inside of apartment buildings. However, there is lack of resonable design criteria for preventing condensation in real life and real surroundings. Therefore, this study is aimed at making a resonable design criteria of preventing condensation by measuring the indoor temperature and humidity in real life. In addition to this, it is aimed at making a resonable outdoor condition and classifying regions by using weather data. The following are the results. The interior criterion for condensation was set up $25^{\circ}C$ and a relative humidity of 55%. The outdoor criterion for condensation was set up $20^{\circ}C$, $-15^{\circ}C$, and $10^{\circ}C$ respectively for the hard frost, middle, and southern areas.

A Development of PM10 Forecasting System (미세먼지 예보시스템 개발)

  • Koo, Youn-Seo;Yun, Hui-Young;Kwon, Hee-Yong;Yu, Suk-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.666-682
    • /
    • 2010
  • The forecasting system for Today's and Tomorrow's PM10 was developed based on the statistical model and the forecasting was performed at 9 AM to predict Today's 24 hour average PM10 concentration and at 5 PM to predict Tomorrow's 24 hour average PM10. The Today's forecasting model was operated based on measured air quality and meteorological data while Tomorrow's model was run by monitored data as well as the meteorological data calculated from the weather forecasting model such as MM5 (Mesoscale Meteorological Model version 5). The observed air quality data at ambient air quality monitoring stations as well as measured and forecasted meteorological data were reviewed to find the relationship with target PM10 concentrations by the regression analysis. The PM concentration, wind speed, precipitation rate, mixing height and dew-point deficit temperature were major variables to determine the level of PM10 and the wind direction at 500 hpa height was also a good indicator to identify the influence of long-range transport from other countries. The neural network, regression model, and decision tree method were used as the forecasting models to predict the class of a comprehensive air quality index and the final forecasting index was determined by the most frequent index among the three model's predicted indexes. The accuracy, false alarm rate, and probability of detection in Tomorrow's model were 72.4%, 0.0%, and 42.9% while those in Today's model were 80.8%, 12.5%, and 77.8%, respectively. The statistical model had the limitation to predict the rapid changing PM10 concentration by long-range transport from the outside of Korea and in this case the chemical transport model would be an alternative method.

Hydrological Analysis in Soyanggang-dam Watershed Using SLURP Model (SLURP 모형을 이용한 유출수문분석 - 소양강댐 유역을 대상으로 -)

  • Lim, Hyuk-Jin;Kwon, Hyung-Joong;Jang, Cheol-Hee;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.8
    • /
    • pp.631-641
    • /
    • 2004
  • The objective of this study is to test the applicability of SLURP (Semi-distributed Land Use-based Runoff Process) on Soyanggang-dam watershed. SLURP model is a conceptual semi-distributed form model that can be used to examine irrigation plan and the effects of proposed changes in water management within a basin or to see what effects external factors such as climate change or changing land cover might have on various water users. Topographical parameters were derived from DEM using TOPAZ and SLURPAZ. Monthly NDVIs were calculated from multi-temporal NOAA/AVHRR images during four years (1998 ∼ 2001). Weather elements (dew-point temperature, solar radiation, maximum/minimum temperature and relative humidify) were obtained from five meteorological stations within and near the study area. To simulate daily hydrograph during 1998 ∼ 2001, the model parameters of each land cover class were optimized by sensitivity analysis and SCE-UA method. Test result of SLURP was summarized by various statistics method (WMO volume error, Nash-Sutcliffe efficiency, mean error and coefficient of variation).

A Study on Nutritional Supplements Intake and Related Factors of Elementary School Students in Incheon with Their Mothers' Answer I. Nutritional Supplements Intake (인천 지역 초등학생의 영양 보충제 섭취 실태 및 섭취 관련 요인의 어머니 대상 연구 I. 섭취 실태)

  • Lee Min-Young;Chang Kyung-Ja
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.15 no.6
    • /
    • pp.633-643
    • /
    • 2005
  • The purpose of study was to investigate nutritional supplements intake of elementary school students aged 7 to 12 years in Incheon The subjects were 631 mothers of schoolchildren and cross sectional study was conducted by a self-administered questionnaire. Nutritional supplements were taken by $42.3\%$ of the surveyed elementary school students. Among nutritional supplements they toot vitamin and mineral accounted for $47.3\%$, herbs and chinese medicine $39.3\%$ and dietary supplements $10.7\%.$ Among reasons for taking nutritional supplements, help for growth, health promotion, supply for deficient nutrients and prevention or treatment of disease were in order. As for the reasons for not taking nutritional supplements, most of the subjects answered that meals are enough in getting nutrients for children Mother of elementary school students usually Dew the health claim of the nutritional supplements before taking the Also they usually got the information of the nutritional supplements 1mm doctors or pharmacist and bought the nutritional supplements at drugstores, oriental medicine clinic and on-line shop in order. As for the effect of nutritional supplements, $43.7\%$ of the subjeces answered as 'effective' and $81.7\%$ of the mother of elementary school students who took nutritional supplements answered positively that they would continue to have their children take it Among the reasons they would continue to have their children take it help for growth ranked the first. therefore, these results my provide basic informations on nutritional supplements used by the elementary school students in Incheon.

  • PDF

Effects of Sulfuric Acid Concentration and Alloying Elements on the Corrosion Resistance of Cu-bearing low Alloy Steels

  • Kim, Ki Tae;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.154-165
    • /
    • 2018
  • During the process of sulfur dioxide removal, flue gas desulfurization equipment provides a serious internal corrosion environment in creating sulfuric acid dew point corrosion. Therefore, the utilities must use the excellent corrosion resistance of steel desulfurization facilities in the atmosphere. Until now, the trend in developing anti-sulfuric acid steels was essentially the addition of Cu, in order to improve the corrosion resistance. The experimental alloy used in this study is Fe-0.03C-1.0Mn-0.3Si-0.15Ni-0.31Cu alloys to which Ru, Zn and Ta were added. In order to investigate the effect of $H_2SO_4$ concentration and the alloying elements, chemical and electrochemical corrosion tests were performed. In a low concentration of $H_2SO_4$ solution, the major factor affecting the corrosion rate of low alloy steels was the exchange current density for $H^+/H_2$ reaction, while in a high concentration of $H_2SO_4$ solution, the major factors were the thin and dense passive film and resulting passivation behavior. The alloying elements reducing the exchange current density in low concentration of $H_2SO_4$, and the alloying elements decreasing the passive current density in high concentration of $H_2SO_4$, together play an important role in determining the corrosion rate of Cu-bearing low alloy steels in a wide range of $H_2SO_4$ solution.

Analysis of the Inhibition Layer of Galvanized Dual-Phase Steels

  • Wang, K.K.;Wang, H.-P.;Chang, L.;Gan, D.;Chen, T.-R.;Chen, H.-B.
    • Corrosion Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.9-14
    • /
    • 2012
  • The formation of the Fe-Al inhibition layer in hot-dip galvanizing is a confusing issue for a long time. This study presents a characterization result on the inhibition layer formed on C-Mn-Cr and C-Mn-Si dual-phase steels after a short time galvanizing. The samples were annealed at $800^{\circ}C$ for 60 s in $N_{2}$-10% $H_{2}$ atmosphere with a dew point of $-30^{\circ}C$, and were then galvanized in a bath containing 0.2 %Al. X-ray photoelectron spectroscopy (XPS) and transmission electron microscopy (TEM) was employed for characterization. The TEM electron diffraction shows that only $Fe_{2}Al_{5}$ intermetallic phase was formed. No orientation relationship between the $Fe_{2}Al_{5}$ phase and the steel substrate could be identified. Two peaks of Al 2p photoelectrons, one from metallic aluminum and the other from $Al^{3+}$ ions, were detected in the inhibition layer, indicating that the layer is in fact a mixture of $Fe_{2}Al_{5}$ and $Al_{2}O_{3}$. TEM/EDS analysis verifies the existence of $Al_{2}O_{3}$ in the boundaries of $Fe_{2}Al_{5}$ grains. The nucleation of $Fe_{2}Al_{5}$ and the reduction of the surface oxide probably proceeded concurrently on galvanizing, and the residual oxides prohibited the heteroepitaxial growth of $Fe_{2}Al_{5}$.

Assessment of microclimate conditions under artificial shades in a ginseng field

  • Lee, Kyu Jong;Lee, Byun-Woo;Kang, Je Yong;Lee, Dong Yun;Jang, Soo Won;Kim, Kwang Soo
    • Journal of Ginseng Research
    • /
    • v.40 no.1
    • /
    • pp.90-96
    • /
    • 2016
  • Background: Knowledge on microclimate conditions under artificial shades in a ginseng field would facilitate climate-aware management of ginseng production. Methods: Weather data were measured under the shade and outside the shade at two fields located in Gochang-gun and Jeongeup-si, Korea, in 2011 and 2012 seasons to assess temperature and humidity conditions under the shade. An empirical approach was developed and validated for the estimation of leaf wetness duration (LWD) using weather measurements outside the shade as inputs to the model. Results: Air temperature and relative humidity were similar between under the shade and outside the shade. For example, temperature conditions favorable for ginseng growth, e.g., between $8^{\circ}C$ and $27^{\circ}C$, occurred slightly less frequently in hours during night times under the shade (91%) than outside (92%). Humidity conditions favorable for development of a foliar disease, e.g., relative humidity > 70%, occurred slightly more frequently under the shade (84%) than outside (82%). Effectiveness of correction schemes to an empirical LWD model differed by rainfall conditions for the estimation of LWD under the shade using weather measurements outside the shade as inputs to the model. During dew eligible days, a correction scheme to an empirical LWD model was slightly effective (10%) in reducing estimation errors under the shade. However, another correction approach during rainfall eligible days reduced errors of LWD estimation by 17%. Conclusion: Weather measurements outside the shade and LWD estimates derived from these measurements would be useful as inputs for decision support systems to predict ginseng growth and disease development.

CMnAl TRIP Steel Surface Modification During CGL Processing

  • Gong, Y.F.;Lee, Y.R.;Kim,, Han-S.;Cooman, B.C.De
    • Corrosion Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.81-86
    • /
    • 2010
  • The mechanisms of selective oxidation of intercritically annealed CMnAl TRIP steels in a Continuous Galvanizing Line (GCL) were studied by cross-sectional observation of the surface and sub-surface regions by means of High Resolution Transmission Electron Microscopy (HR-TEM). The selective oxidation and nitriding of an intercritically annealed CMnAl TRIP steel in a controlled dew point 10%$H_2+N_2$ atmosphere resulted in the formation of c-xMnO.$MnO_2$ (1${\leq}$x<3) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) particles on the steel surface. Single crystal c-xMnO.$SiO_2$ ($2{\leq}x{\leq}4$) oxide particles were also observed on the surface. A thin film of crystalline c-xMnO.$SiO_2$ (2${\leq}$x<3) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) was present between these particles. In the sub-surface region, internal oxidation, nitriding and intermetallic compound formation were observed. In the first region, large crystalline c-xMnO.$SiO_2$ ($1{\geq}x{\geq}2$) and c-xMnO.$Al_2O_3$ ($x{\geq}1$) oxides particles were present. In the second region, c-AlN particles were observed, and in a third region, small $MnAl_x$ (x>1) intermetallic compound particles were observed.

Humidity Sensitive Properties of Copolymers of Polystyrene Contains Phosphonium Salts (포스포늄 염을 포함한 폴리스티렌 공중합체의 감습 성질)

  • Paek, Jee-Seon;Gong, Myoung-Seon
    • Korean Journal of Materials Research
    • /
    • v.5 no.6
    • /
    • pp.715-722
    • /
    • 1995
  • Vinylbenzyl triphenyl phosphonium chloride (VTPC) was prepared for the humid membrane. The humidity sensitive memo)lane was composed of copolymers, which have differnet content of VTPC and styrene (VTPC : ST=1 : 0.7 : 3, 5 : 5, 3 : 7). The changes in electrical properties of copolymers with relative humidity were measured. It was found that the impedance decreased with an increase of the content of VTPC in the humid membrane, and the Impedance also decreased with an increase of thickness of humid membrane. The copolymer derived from same equip of VTPC and ST showed 12M$\Omega$-100M$\Omega$ at 70%RH-90%RH, which was required for the current humidity sensor operating at high humidity or dew point. The temperature dependence coefficient at a temperature range 15$^{\circ}C$∼35$^{\circ}C$ was found to be -0.5%RH/$^{\circ}C$ and the hysterisis fabled within the range ${\pm}$2%RH. The response time was found to be 40seconds for varing relative humidity from 75% RH to 95%RH and vice versa.

  • PDF

A Case Study of Tsukuba Tornado in Japan on 6 May 2012

  • Choo, Seonhee;Min, Ki-Hong;Kim, Kyung-Eak;Lee, Gyuwon
    • Journal of the Korean earth science society
    • /
    • v.39 no.5
    • /
    • pp.403-418
    • /
    • 2018
  • This study conducted synoptic and mesoscale analyses to understand the cause of Japan Tsukuba tornado development, which occurred at 0340 UTC 6 May 2012. Prior to the tornado occurrence, there was a circular jet stream over Japan, and the surface was moist due to overnight precipitation. The circular jet stream brought cold and dry air to the upper-level atmosphere which let strong solar radiation heat the ground with clearing of sky cover. A tornadic supercell developed in the area of potentially unstable atmosphere. Sounding data at Tateno showed a capping inversion at 900 hPa at 0000 UTC 6 May. Strong insolation in early morning hours and removal of the inversion instigated vigorous updraft with rotation due to vertical shear in the upper-level atmosphere. This caused multiple tornadoes to occur from 0220 to 0340 UTC 6 May 2012. When comparing Tateno's climatological temperature and dew-point temperature profile on the day of event, the mid-level atmosphere was moister than typical sounding in the region. This study showed that tornado development in Tsukuba was caused by a combination of (a) topography and potential vorticity anomaly, which increased vorticity over the Kanto Plain; (b) vertical shear, which produced horizontal vortex line; and c) thermal instability, which triggered supercell and tilted the vortex line in the vertical.