• Title/Summary/Keyword: Devices

Search Result 25,104, Processing Time 0.05 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

Improving Curing Rate and Physical Properties of Korean Dendropanax Lacquer with Thermal and Photo Initiator by Dual Curing (이중경화법을 이용한 열개시제 및 광개시제가 배합된 황칠도료의 경화속도 촉진 및 물성향상 연구)

  • Hwang, Hyeon-Deuk;Moon, Je-Ik;Park, Cho-Hee;Kim, Hyun-Joong;Hwang, Baik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.4
    • /
    • pp.333-340
    • /
    • 2010
  • The Korean Dendropanax lacquer, made from a natural resinous sap from Dendropanax orbifera Lev., was used as a golden and transparent varnish for the traditional artifacts (armor uits, helmets, arrowheads, etc.) to make them be brilliant golden color. The cured film of the acquer has excellent protective properties such as weatherability, water resistance, and nticorrosive. But, one of disadvantages is that takes a long time and much energy to fulfill curing the lacquer. The chemical constituents of the lacquer contained conjugated diene compounds s the photopolymerizable monomers. These monomers easily polymerized in sunlight to form olden-colored, hard-coating films in a short time. Photooxidation may be one of the most mportant reactions in the chemistry of the lacquer. Although the Korean Dendropanax Lacquer hould be dried to a thoroughly dry stage to achieve optimal film properties, curing with elevated emperatures may be required for the protracted curing time at atmospheric temperature. So we ntended to accelerate the curing rate of the lacquer by dual curing of thermal and radiation uring. The effect of thermal initiator on the thermal curing reaction was evaluated by monitoring he changes in double bond peak with FT-IR. Then the curing rate of the lacquer blended with hermal initiator and photoinitiator together was measured during dual curing using a RPT with V spot curing machine. Thermal initiator not only accelerated the curing rate but also improved he physical property. And the curing rate of the Korean Dendropanax lacquer was improved by ual curing method of thermal and UV curing. According to these results, the application area of he Korean Dendropanax lacquer could be expanded to surface coatings for electronic devices uch as mobile phones or electronics.

Clinical Analysis of 500 Cases of Coronary Artery Bypass Grafting (관상동맥 우회술 500례의 임상적 고찰)

  • Shin, Yoon-Cheol;Kim, Ki-Bong;Ahn, Hyuk;Chae, Hurn;Rho, Joon-Ryang;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.525-531
    • /
    • 1999
  • Background: We analyzed five hundred patients who underwent either isolated or concomitant coronary artery bypass grafting(CABG) between November 1981 and June 1997. Material and Method: There were 330 males and 170 females with a mean age of 57.4$\pm$8.9 years. To evaluate the preoperative status, we performed electrocardiograghy, echocardiography, MIBI scan, Duplex sonogram, common blood test including CK and LDH and coronary angiography. Result: Preoperative clinical diagnoses were unstable angina in 282 (56.4%), stable angina in 141 (28.2%), postinfarction angina in 58 (11.6%), acute myocardial infarction in 8 (1.6%), variant angina in 7 (1.4%) and failed percutaneous transluminal coronary angioplasty in 4 (0.8%) patients. Preoperative angiographic diagnoses were three-vessel disease in 263 (52.6%), two-vessel disease in 93 (18.6%), one-vessel disease in 71 (14.2%), left main disease in 68 (13.6%), and others in 5 (1.0%) patients. Patients had various risk factors for coronary disease, and the frequency of the risk factors such as hypertension, diabetes and smoking showed increasing tendency year by year. We used saphenous vein grafts in 1143, internal thoracic artery grafts in 442, radial artery graft in 17, and gastroepiploic artery graft in 1 anastomosis. The mean number of grafts was 3.2$\pm$1.2 per patient. Concomitant operations were prosthetic valve replacement or valvuloplasty in 31, coronary endarterectomy and angioplasty in 27, left main coronary angioplasty in 13, carotid endarterectomy in 5, and neurologic problems, bleeding, and perioperative myocardial infarction. The mean follow-up period was 25$\pm$23 months and there were 5 cases of reoperation. Conclusion: We hope that the surgical results would improve with the accumulation of experience, application of new myocardial protection technique, and timely intervention of mechanical assisted devices.

  • PDF

Assessment Techniques of Heavy Metal Bioavailability in Soil - A critical Review (토양 중 중금속 생물유효도 평가방법 - 총설)

  • Kim, Kwon-Rae;Owens, Gary;Naidu, Ravi;Kim, Kye-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.4
    • /
    • pp.311-325
    • /
    • 2007
  • The concept of metal bioavailability, rather than total metal in soils, is increasingly becoming important for a thorough understanding of risk assessment and remediation. This is because bioavailable metals generally represented by the labile or soluble metal components existing as either free ions or soluble complexed ions are likely to be accessible to receptor organismsrather than heavy metals tightly bound on soil surface. Consequently, many researchers have investigated the bioavailability of metals in both soil and solution phases together with the key soil properties influencing bioavailability. In order to study bioavailability changes various techniques have been developed including chemical based extraction (weak salt solution extraction, chelate extraction, etc.) and speciation of metals using devices such as ion selective electrode (ISE) and diffusive gradient in the thin film (DGT). Changes in soil metal bioavailability typically occur through adsorption/desorption reactions of metal ions exchanged between soil solution and soil binding sites in response to changes in environment factors such as soil pH, organic matter (OM), dissolved organic carbon (DOC), low-molecular weight organic acids (LMWOAs), and index cations. Increasesin soil pH result in decreases in metal bioavailability through adsorption of metal ions on deprotonated binding sites. Organic matter may also decrease metal bioavailability by providing more negatively charged binding sites, and metal bioavailability can also be decreases as concentrations of DOC and LMWOAs increase as these both form strong chelate complexeswith metal ions in soil solution. The interaction of metal ions with these soil properties also varies depending on the soil and metal type.

A STUDY ON THE SKELETAL CHANGES IN MAXILLARY PROTRACTION OF THE SKELETAL GLASS III MALOCCLUSION PATIENTS (골격성 III급 부정교합 환자에서 상악골 전방 견인시 일어나는 골격 변화 양상에 관한 연구)

  • Lee, Young-Ji;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.533-546
    • /
    • 1998
  • A Skeletal Class III malocclusion may be the result of a large mandible, a small maxilla or combination of the two. Protraction devices for the maxilla are used to promote the growth of a deficient maxilla by applying extraoral force to actively growing patients. This study has been performed to determine whether there are significant differences in skeletal and dental changes between FH/Pal 1 and FH/Pal 2 group, SNA 1 and SNA 2 group, SNB 1 and SNB 2 group, and LFH 1 and LFH 2 group after RME and facial mask therapy. The results of this study can be summarized and concluded as follows ; 1. In all patients after maxillary protraction, the maxilla and maxillary dentitions moved forward, and the mandible rotated backward and downward. In most of them, palatal plane is tends to have an upward inclination. 2. The FH/Pal group 1, having an upward inclination of the palatal plane as a result of Facial mast showed statistically significant maxillary forward movement compared to the FH/Pal group 2. 3. The SNA group 1 showed significantly less mandibular backward movement and there was a tendency for the palatal plane to upward inclination compared to SNA group 2. 4. The SNB group 1 showed significantly less maxillary forward movement, but the vertical dimension, especially the lower facial height increased by mandibular downward rotation compared to SNB group 2. 5. LFH group 1, which had large saddle angle and posterior positioned mandible in the pre-treatment stage, showed maxillary protraction effect without significant increase in lower facial height compared to LFH group 2.

  • PDF

A Study on Driving Safety Evaluation Criteria of Personal Mobility (퍼스널 모빌리티(Personal Mobility)의 주행안전성 평가지표 연구)

  • Park, Bumjin;Roh, Chang-gyun;Kim, Jisoo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.1-13
    • /
    • 2018
  • Divers types of Personal Mobility(PM) are appeared on the market after the Segway is introduced. PMs have propagated very rapidly with their ease of use, and accidents related with PM show a sudden increase. Many studies on the PM are performed as its trend, but dring safety of passengers are excluded. In this study, criteria which can be adopted for PM's driving safety evaluation are reviewed. Also result of driving safety evaluation on 3 types of PM(wheel chair, kickboard, scooter(seating/standing) and walking using deducted criteria is given. COG(Center of the gravity) and SM(Stability Metric) are finally selected two criteria among many of them used in other fields. COG indicates how the center of mass deviates from the direction of the gravity. SM is a normalized value of generated force when PM moves as internal force, angular momentum, and ground reaction force. 0 means stop, and negative value means rollover, so it can be used for safety evaluation of PM. Average and standard deviation of measurement are standard of safety on the COG analysis. Wheel chair is the most safe and kickboard is the most unstable on the COG analysis. Wheel chair is also ranked as top safe on the SM analysis. Among two riding types(seating and standing) on the scooter, seating type is evaluated more safer than standing type. It is proposed that more various type of PMs are need to get safety evaluation for drivers and devices themselves together.

Development of Intelligent Severity of Atopic Dermatitis Diagnosis Model using Convolutional Neural Network (합성곱 신경망(Convolutional Neural Network)을 활용한 지능형 아토피피부염 중증도 진단 모델 개발)

  • Yoon, Jae-Woong;Chun, Jae-Heon;Bang, Chul-Hwan;Park, Young-Min;Kim, Young-Joo;Oh, Sung-Min;Jung, Joon-Ho;Lee, Suk-Jun;Lee, Ji-Hyun
    • Management & Information Systems Review
    • /
    • v.36 no.4
    • /
    • pp.33-51
    • /
    • 2017
  • With the advent of 'The Forth Industrial Revolution' and the growing demand for quality of life due to economic growth, needs for the quality of medical services are increasing. Artificial intelligence has been introduced in the medical field, but it is rarely used in chronic skin diseases that directly affect the quality of life. Also, atopic dermatitis, a representative disease among chronic skin diseases, has a disadvantage in that it is difficult to make an objective diagnosis of the severity of lesions. The aim of this study is to establish an intelligent severity recognition model of atopic dermatitis for improving the quality of patient's life. For this, the following steps were performed. First, image data of patients with atopic dermatitis were collected from the Catholic University of Korea Seoul Saint Mary's Hospital. Refinement and labeling were performed on the collected image data to obtain training and verification data that suitable for the objective intelligent atopic dermatitis severity recognition model. Second, learning and verification of various CNN algorithms are performed to select an image recognition algorithm that suitable for the objective intelligent atopic dermatitis severity recognition model. Experimental results showed that 'ResNet V1 101' and 'ResNet V2 50' were measured the highest performance with Erythema and Excoriation over 90% accuracy, and 'VGG-NET' was measured 89% accuracy lower than the two lesions due to lack of training data. The proposed methodology demonstrates that the image recognition algorithm has high performance not only in the field of object recognition but also in the medical field requiring expert knowledge. In addition, this study is expected to be highly applicable in the field of atopic dermatitis due to it uses image data of actual atopic dermatitis patients.

  • PDF

A Study on the Infection Control Attitude of Dental Hygienists (일부 치과위생사의 감염방지 태도에 관한 조사연구)

  • Kim, Ji-Hee;Lee, Kaa-Yean
    • Journal of dental hygiene science
    • /
    • v.9 no.1
    • /
    • pp.129-136
    • /
    • 2009
  • The purpose of this study was to examine the infection control attitude of dental hygienists and the relationship between their attitude and general characteristics. The subjects in this study were 235 dental hygienists who received local in-service education on April 27, 2008. The survey was conducted by this researcher with questionnaires that included 11 items about general characteristics and 41 about attitude of dental infection. The findings of the study were as follows: 1. The dental hygienists investigated got a mean of 2.96 out of possible three points on hand washing, which was a high score. Those who had never been exposed to the blood of patients scored better than the others who hadn't. As for infection control attitude of protective personal devices, they got 2.01 out of possible three points. Those who were at the age of 26 to 30 and who had ever received infection control education got better scores. 2. Concerning attitude toward surface disinfectant, they got 1.95 out of possible three points. whose age was shorter, whose career was shorter, who were in charge of treatment, who served at general hospitals and who had ever received infection control education got better scores. In regard to attitude to surface disinfection methods, they got 1.83 out of possible three points. Those who had ever received infection control education got better scores. 3. As for equipment disinfection, they got 2.43 out of possible three points. Those who worked at dental hospitals and who had ever received infection control education got better scores. Concerning attitude to disposal of scrapped materials, they got 2.92 out of possible three points, and all the intergroup gaps weren't significant. 4. Overall, the dental hygienists got a mean of 2.08 out of possible three points on dental infection control, and those who worked at dental hospitals and who had ever received infection control education took a better attitude to dental infection control.

  • PDF

A Study on Actual Conditions for Prevention of Infections by Dental Hygienists (치과위생사의 감염 예방 실태 조사)

  • Nam, Young-Shin;Yoo, Jung-Sook;Park, Myung-Suk
    • Journal of dental hygiene science
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2007
  • This study aimed to provide basic information on dental hygienists' practicing the prevention of infections by figuring out their actual conditions in dental clinics. The subjects of the study were the dental hygienists who participated in the continuing medical education of Incheon & Gyeonggi-do association and Seoul city association in October and November 2005 and the self-administered surveys were used for the prevention of infections. The results were as below. 1. In terms of education experiences of infection prevention, those who answered "there were" were 72 persons (42.9%) and those who followed the educational route for infection prevention were "through the in-house education from the hospital" and they were 42 persons (58%), which were highest. 2. In terms of the injury experiences, those who answered "there were" were 147 persons (87.5%) and the number of annual injury out of 147 persons with injury experiences was 7.7 time. For the tools that were damaged, 125 persons (75%) damaged the "explorer," which was highest. 3. For the experiences of being infected with contagious diseases, those who answered "there were" were 6 persons (3.6%) and there were four persons for "hepatitis B", one person for "rubella" and one person for "TB." 4. The questions with high practice scores were as in the following: "2. I wash my hands after conducting medical examinations (1.86 points)," "7. I always close the lid of a shot of Novocain after doing local anesthesia (1.86 points)" and "20. I separate and collect the wastes and give them to those who treat accumulated materials (1.85 points)". Meanwhile, the questions with low practice scores were as below: "16. I change my medical gowns (doctor wears) once a day (0.24 point)" and "I wash my medical gowns every time after examining patients with contagious diseases (0.52 points)." 5. The question with high knowledge was as below: "1. The contagion during the dental treatment is determined by source of infection, infection methods, infection routes and the host that is prone to infection (0.95 point)" and the question with the lowest knowledge was "5. HBV(hepatitis B) is destroyed after adding 95oC of heat for more than 5 minutes (0.27 points)." 6. The question with the highest organization-related factors was "I am always ready to use a mask, gloves, etc. if necessary" (0.89 points)" and the question with the lowest score was "There is a guideline that I can refer when I am exposed to dangerous situations related to the contagion in my workplace (0.33 point)." 7. In terms of the equipment conditions of protectors in medical environments, 168 persons for (disposable) mask (100%), 167 persons for disposable gloves (Latex) (99.4%), which meant that most of them were equipped with them. On the contrary, 108 persons (64.3%) are equipped with the protectors for frontal faces, which is the lowest and 165 persons (98.2%) said that they had autoclave in their disinfecting and sterilizing devices.

  • PDF

Micro-Structure and Magnetic Properties of Electroless Co-W-P Alloy Deposits Formed (무전해 Co-W-P 합금 도금 층의 미세구조와 자기적 특성)

  • Yun, Seong-Ryeol;Han, Seung-Hui;Kim, Chang-Uk
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.97-106
    • /
    • 2000
  • In these respects the purpose of this research is manufacturing Co-W-P alloy thin film on the corning glass 2948 by electroless plating method using $NaH_2PO_2H_2O$ (sodium hypophosphite) as a reductant, and analyzing deposition rate, alloy composition, microstructure, and magnetic characteristics at various pH's and temperatures. For Co-P alloy thin film, the reductive deposition reaction occurred only in basic condition, not in acidic condition. The deposition rate increased as the pH and temperature increased, and the optimum condition was found at the pH of 10 and the temperature of 8$0^{\circ}C$. Also magnetic characteristics was found to be most excellent at the pH of 9 and the temperature of 7$0^{\circ}C$, resulting in the coercive force of 870Oe and the squareness of 0.78. At this condition, the contents of P was 2.54% and the thickness of the film was 0.216$\mu\textrm{m}$. For crystal orientation, we could not observe fcc for $\beta$-Co. On the other hand, (1010), (0002), (1011) orientation of hcp for $\alpha$-Co was observed. We could confirm the formation of longitudinal magnetization from dominant (1010) and (1011) orientation of Co-P alloy. For Co-W-P alloy thin film, coercive force was 500Oe and squareness was 0.6. For crystal orientation, (0002) orientation of $\alpha$-Co was dominatly found. Then we could confirm the formation of perpendicular magnetization. The content of P was constant at 0.8$\pm$0.2% and the content of W increased as the concentration of Na$_2$WO$_4$increased. When the concentration of Na$_2$WO$_4$was 0.1mol/L, the composition of W was 20%. We observed the changes of magnetic characteristics and microstructure of thin film depositions of Co-W-P by the heat treatment. For heat treatment, the temperature was increased step by step to 10$0^{\circ}C$, 20$0^{\circ}C$, 30$0^{\circ}C$, and 40$0^{\circ}C$ and it took 1 hour at each step in the reductive condition of hydrogen gas. By the heat treatment, flatness of surface was improved, but there were no changes on the magnetic characteristics and the microstructures.

  • PDF