• Title/Summary/Keyword: Device-to-device Communication

Search Result 3,523, Processing Time 0.034 seconds

An Efficient Game Theory-Based Power Control Algorithm for D2D Communication in 5G Networks

  • Saif, Abdu;Noordin, Kamarul Ariffin bin;Dimyati, Kaharudin;Shah, Nor Shahida Mohd;Al-Gumaei, Yousef Ali;Abdullah, Qazwan;Alezabi, Kamal Ali
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.7
    • /
    • pp.2631-2649
    • /
    • 2021
  • Device-to-Device (D2D) communication is one of the enabling technologies for 5G networks that support proximity-based service (ProSe) for wireless network communications. This paper proposes a power control algorithm based on the Nash equilibrium and game theory to eliminate the interference between the cellular user device and D2D links. This leadsto reliable connectivity with minimal power consumption in wireless communication. The power control in D2D is modeled as a non-cooperative game. Each device is allowed to independently select and transmit its power to maximize (or minimize) user utility. The aim is to guide user devices to converge with the Nash equilibrium by establishing connectivity with network resources. The proposed algorithm with pricing factors is used for power consumption and reduces overall interference of D2Ds communication. The proposed algorithm is evaluated in terms of the energy efficiency of the average power consumption, the number of D2D communication, and the number of iterations. Besides, the algorithm has a relatively fast convergence with the Nash Equilibrium rate. It guarantees that the user devices can achieve their required Quality of Service (QoS) by adjusting the residual cost coefficient and residual energy factor. Simulation results show that the power control shows a significant reduction in power consumption that has been achieved by approximately 20% compared with algorithms in [11].

Research on the HSE Application with Smart Device and Biometrics (스마트디바이스를 이용한 HSE 적용에 관한 연구)

  • Woo, Jong Hun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.19 no.2
    • /
    • pp.157-168
    • /
    • 2014
  • In this paper, HSE (Health and Safety Environments) research with smart device and biometrics is conducted for the worker's HSE enhancement in the manufacturing shop floor. Today, various kinds of smart devices are popularized extensively. In addition, the wearable type devices are being introduced such as google glass very recently. Smart device of werable type is exptected to bring great opportunity out in terms of HSE functionality. Smart devices of phone or tablet type are being used for on-line work between control center and manufacturing shop floor by virtue of wireless communication. However, those devices are not appropriate for detecting of worker's physical senses such as temperature and pulse. In this paper, we developed a glass type smart device and required funictions for HSE enhancement with the investigation of biometrics technology. Also, required sensors are investigated for the detecting of temperature, pulse and noxious gasses. Smart device of glass type has advantages in that most senses of personnel are gathered around faces, and also it's possible to detect neutral axis of body because the wearing location is fixed. We expect that the proposing HSE product of glass type smart device could contribute the enhancement of the HSE of manufacturing shop floor.

On the Untact ICT based New Concept Storage Device Design by Interworking SysML and CAD Data to Improve the Development Efficiency

  • Kim, Myung Sung;Park, Jae Min;Kim, Young Min
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.258-269
    • /
    • 2022
  • In these days, innovative functions are required to unmanned parcel delivery lockers. As non-face-to-face transactions become the center due to the recent COVID-19 pandemic, many problem occurs in society such as theft crimes and lack of loading space. Therefore, New concept storage device is developed in korea. It has the functions that minimizes empty spaces by using the internal transport device to enable efficient space loading and refrigerate goods such as foods. In order to systematically approach the system design of the unmanned parcel delivery lockers which is the new function is applied, We applied model-based system engineering to improve the development efficiency and use a system modeling language to express the system. We conducted interworking research of CAD data including system modeling and design data. it is expected that this method will increase the effective development efficiency such as maintenance traceability and reduction of development period and cost.

Process Management System using a PC (PC를 이용한 공정관리시스템 개발)

  • Song, Joon-Yeob;Lee, Seung-Woo;Lee, Hyun-Yong
    • IE interfaces
    • /
    • v.6 no.2
    • /
    • pp.171-181
    • /
    • 1993
  • In this study, a process management system is designed that can automatically control the heat treating atmosphere, and a managment software is developed to monitor and control continously the heat treating process using a n interface device. Especially, a communication protocol is developed to control and monitor atmosphere condition, temperature, surrounding gas, and time. The developed interface device, called COMPORT SELECTOR is to send and receive information from PID controllers and PLC via RS-232C communication. This system will reduce manufacturing cost and cycle time, and improve the effectiveness of working process and quality.

  • PDF

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.

Implementation of Simulator for Navigation Control System of Bimodal Tram (바이모달 저상굴절차량의 자동운전시스템을 위한 시뮬레이터 구현)

  • Ryu, Je;Hwang, Byoung-Il;Lee, Sang-Nam;Ryu, Hee-Moon;Byun, Yeun-Sub
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.424-432
    • /
    • 2009
  • This paper discusses about the implementation of a simulator for the Navigation Control System(NCS) of bimodal tram. To operate a NCS of bimodal tram, values of all sorts of sensors installed in bimodal tram should be transmitted to the NCS, and the NCS calculates the measured sensor values to determine traveling direction, traveling speed, current position etc. The implementation of the simulator consists of a device applying driver's input transaction function & virtual sensor program and a sub-rack device that controls communication with the NCS to evaluate navigation control function. The virtual sensor program can create routes (map), traveling profiles & seat information et cetera in order to transmit to the NCS, analyzes driver's input values and NCS output values to create virtual sensor values. The sub-rack device takes charge of communication with the NCS using CAN-OPEN, CAN-J1939, MVP protocols. This paper discusses about the implementation of the simulator and afterwards analyzes and evaluates the NCS simulation results.

  • PDF

LDL Cholesterol Testing Device using Serial Reflected Face-to-Face Mirror System

  • Choi, Min-Seong;Yoo, Jae-Chern
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.296-299
    • /
    • 2013
  • A low density lipoprotein (LDL) cholesterol testing device, structured with serial reflected face-to-face mirror (SRM) allowing spectrophotometry measurements, is presented. The spectrophotometry has been employed to measure the amount of light that a sample absorbs, but it generally should have had path length longer than 10 mm to secure enough sensitivity. Such requirement of path length has often been problematic in implementing a thin type of lab on a disc (LOD). We developed the SRM system which was implemented in a detection chamber with 1.4mm thickness, providing path length longer than 10mm, and thus straightforwardly being applicable to LOD as thin as a compact disc. The experimental results show that the SRM system gives not only a much thinner design compared to the conventional spectrophotometry-based LOD but also a comparable performance to already commercialized spectrometers.

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

A Study on the Color Proofing CMS Development for the KOREA Offset Printing Industry (한국 오프셋 인쇄산업에 적합한 CMS 개발에 관한 연구)

  • Song, Kyung-Chul;Kang, Sang-Hoon
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.25 no.1
    • /
    • pp.121-133
    • /
    • 2007
  • The CMS(color management system) software was to enable consistent color reproduction from original to reproduction. The CMS was to create RGB monitor and printer characterization profiles and then use the profiles for device independent color transformation. The implemented CMM(color management module) used the CIELAB color space for the profile connection. Various monitor characterization model was evaluated for proper color transformation. To construct output device profile, SLI(sequential linear interpolation) method was used for the color conversion from CMYK device color to device independent CIELAB color space and tetrahedral interpolation method was used for backward transformation. UCR(under color removal) based black generation algorithm was used to construct CIELAB to CMYK LUT(lookup table). When transforming the CIE Lab colour space to CMYK, it was possible to involve the gray revision method regularized in the brightness into colour transformation process and optimize the colour transformation by black generation method based on UCR technique. For soft copy colour proofing, evaluating several monitor specialism methods showed that LUT algorithm was useful. And it was possible to simplify colour gamut mapping by constructing both the look-up table and the colour gamut mapping algorithm to a reference table.

  • PDF

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.