• Title/Summary/Keyword: Device-to-Device

Search Result 25,364, Processing Time 0.052 seconds

Development and use of Supporting Device for Patellar X-ray Imaging (슬개골 엑스선 영상 촬영을 위한 보조기구의 개발과 활용)

  • Rhee, Do-Byung;Seo, Seung-Jun;Choi, Hyun-Woo;Lee, Sang-Hun;Kim, Jong-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.165-171
    • /
    • 2020
  • In this study, it focuses on the development of radiographic devices for patellar imaging. On the previous X-ray examination of patella and patellofemoral joint, it analyzed the problems which could affect the results: unstable patients' pose, radiation exposure, and deterioration of image quality. The purpose of the research is to propose a future use of a developed device with an explanation of the process, function, and advantage of the device including the methods. The device is developed to focus on the diagnosis of the longitudinal and longitudinal fractures of the patella and patella/femoral joint, displacement such as dislocation, bone formation, stenosis of the patella/femorla joint, and cartilage wear. Due to the patient's anxious posture, it caused a shaking image, overlapping structures, and etcs, these factors challenge to diagnose accurately. In addition, the existing Settegast method and Hughston method, which are most frequently performed in the hospital field, are not suitable for the presence or absence of features or dislocation due to the heavy load on the patella of the patient. The developed device requires patients in a lying position and placing only their leg on the device, it increases the conveniences of the examination and decreases unnecessary radiation exposure of the patient except the patellar examination area. Moreover, one of the systems in the device fixes the detector, where the patients no longer need to hold the detector nor be in unstable posture, but describes the structure of the patella/femoral joint more clearly. Hoping the device will apply to more patients.

Exploratory Study on the Success Factors of Rehabilitation Medical Device Cluster

  • Kim, Sung-Jin;Kim, Gyu-Bae
    • The Journal of Economics, Marketing and Management
    • /
    • v.6 no.4
    • /
    • pp.17-27
    • /
    • 2018
  • Purpose - As Korea is reaching a post-aged society, the number of chronic illness is increasing, and the demand for rehabilitation medical device is growing. Although there is high potential for the growth in rehabilitation industry, because most of the related companies in Korea are relatively small, lacking capital or R&D resource, it is difficult for them to create an innovative product, and currently most of the high-tech equipments are imported. Therefore a medical device cluster, where business, research, medical institutes and universities may work cooperatively to enhance research development and solve issues is necessary for future development. Research design, data, methodology - In this method we have done a literature review of the rehabilitation industry and industrial cluster. Based on the studies, we have conducted an exploratory factor analysis by studying examples of foreign and domestic medical clusters and drawing success factors in forming a medical cluster. Next based on the studies we have conducted a survey to domestic medical device companies to find their difficulties and needs to form a successful medical device cluster. Results - This paper provides both theoretic review on success factors of forming a medical device cluster and practical analysis using case study and survey. Conclusion - The significance of this paper is that based on the literature review, we have compared actual examples of domestic/foreign medical clusters and drawn difference and coincidence between literature and actual cluster success factor. We were also able to conduct a survey on actual medical device companies and through the results we were able to search difficulties and necessities of medical device companies.

Development of Tomotherapy couch device capable of yaw-directional correction (Yaw방향의 보정이 가능한 Tomotherapy couch device의 개발)

  • Chae, Moon Ki;Kwon, Dong Yeol;Sun, Jong Lyool;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.139-151
    • /
    • 2018
  • Objectives : A self-made "Tomotherapy couch device" capable of correcting the Yaw direction was fabricated and evaluated for its usefulness. Materials and Methods : "Tomotherapy couch device" capable of correcting the Yaw direction is made of rigid fibreboard with a flexural strength of $200kg/cm^2$. CBCT Image from Novalis Tx and Iso-Align Phantom from MED-TEC were used to evaluate the physical accuracy. The treatment plan was designed using Accuray $Precision^{TM}$ and In House Head and Phantom. Accuray $PrecisionART^{TM}$ and $Precision^{TM}$ was used to evaluate dose. Results : Evaluation results, the self-fabricated device accurately corrected the setup error, Target dose was within 95 %~107 % of all. In order to directly evaluate the OAR dose according to the Yaw change, the absolute dose was measured. As a result, when the error in the Yaw direction was $3^{\circ}$, the specific OAR showed a maximum difference of 18.4 %. Conclusion : "Tomotherapy couch device" capable of correcting the Yaw direction can be manufactured at a lower cost compared to the effect, and it can prevent the patient's MVCT image dose for re-imaging. Accurate radiation therapy without errors can be performed.

  • PDF

$CIEL^{*}a^{*}b^{*}$-CMY nonlinear color transformation based on equi-visual perception color sampling (등시지각 색 샘플링에 기반한 $CIEL^{*}a^{*}b^{*}$-CMY로의 비선형 색변환)

  • 류승민;오현수;이철희;유미옥;최환언;안석출
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.1
    • /
    • pp.103-112
    • /
    • 2000
  • The color space transformation to link device-dependent color spaces and device-independent color spaces is essential for device characterization and cross-media color reproduction. There are various color conversion methods such as regression, 3D interpolation with LUT(look-up table), and neural network. In the color transformation with these methods, the conversion accuracy is essentially based on the sample data to be exploited for device characterization. In conventional method, color samples are uniformly selected in device-dependent space such as CMY and RGB. However, distribution of these color samples is very non-uniform in device-independent color space such as CIEL*a*b*. Accordingly, the conversion error in device-independent color space is irregular according to the distribution of the samples. In this paper, a color sampling method based on equi-visual perception is proposed to obtain approximate uniform color samples in CIEL*a*b* space. In order to evaluate transformation accuracy of proposed method, color space transformations are simulated using regression, 3D interpolation with LUT and neural network techniques, respectively.

  • PDF

Development of the Portable Weighing Scale Automatic Device for Disabled Wheelchair Users (휠체어 탑승 장애인을 위한 이동형 체중측정 자동화 장치 개발)

  • Jang, Kyung-Bae;Lee, Kyeong-Wan;Koo, Do-Hoon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • Wheelchair users have a difficulty in managing their weight because there is lack of measure systems and even though the users have the system, it costs too much. Thus, purpose of this study is for developing the portable weight scale automatic device to help wheelchair users by monitoring their weight on the wheelchairs in real time. Portable weight scale automatic device composed by four strain gauges, and the device was connected with mobile phone so that wheelchair users were able to check their weight in real time. In order to evaluate the device performance, 10 normal subjects and 10 disabled subjects participated in this study. The subjects' truth weight and measured weight by the device are compared. The weigh difference within normal subjects was $0.75{\pm}0.80kg$, and the weigh difference within disabled subjects was $1.02{\pm}0.74kg$. Difference between the truth weigh and the measured weigh were not statistically different. The reason for this error occurred is inaccuracy of the loadcell installation and calibration. If this problems get solved, the measured indicator is expected to help wheelchair users to manage their weight.

Debug Port Protection Mechanism for Secure Embedded Devices

  • Park, Keun-Young;Yoo, Sang-Guun;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.2
    • /
    • pp.240-253
    • /
    • 2012
  • In this paper we propose a protection mechanism for the debug port. While debug ports are useful tools for embedded device development and maintenance, they can also become potential attack tools for device hacking in case their usage is permitted to hackers with malicious intentions. The proposed approach prevents illicit use of debug ports by controlling access through user authentication, where the device generates and issues authentication token only to the server-authenticated users. An authentication token includes user access information which represents the user's permitted level of access and the maximum number of authentications allowed using the token. The device authenticates the user with the token and grants limited access based on the user's access level. The proposed approach improves the degree of overall security by removing the need to expose the device's secret key. Availability is also enhanced by not requiring server connection after the initial token generation and further by supporting flexible token transfer among predefined device groups. Low implementation cost is another benefit of the proposed approach, enabling it to be adopted to a wide range of environments in demand of debug port protection.

The Development of Acupuncture- Moxibustion Device for 4 points around GV20(Baihui) (백회와 사신총 혈위에 적합한 침구 소자의 개발)

  • Jo, Bongkwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.2
    • /
    • pp.101-108
    • /
    • 2015
  • Objectives This paper focused on developing the acupuncture-moxibustion device for head. Disadvantages of the existing devices for head moxibustion are its hume and inconvenience in operating because of the hair. Methods The proposed acupuncture-moxibustion device for GV20(Baihui) is 10mm long as needle body and 6mm long as needle root whose feature are 1~2 turns spiral coil. The spiral coil contains the moxa in order not to drop the moxa while operating Results The direct temperature on the burning moxa were measured by TK-305 infrared thermometer. But the direct temperature on the needle of acupuncture-moxibustion device were not able to measure by TK-305 infrared thermometer. By definition equation, the indirect temperatures on the needle of acupuncture-moxibustion device were able to be calculated. Conclusion A very safe, small and cheap acupuncture-moxibustion device for GV20(Baihui) of head is proposed. It will be useful to generate the heat shock protein and to operate in preventing and curing the Alzheimer's disease.

Bi-directional Two Terminal Switching Device based on SiGe for Spin Transfer Torque (STT) MRAM

  • Yang, Hyung-Jun;Kil, Gyu-Hyun;Lee, Sung-Hyun;Song, Yun-Heub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.385-385
    • /
    • 2012
  • A two terminal N+/P/N+ junction device to replace the conventional selective transistor was studied as a bilateral switching device for spin transfer torque (STT) MRAM based on 3D device simulation. An N+/P/N+ junction structure with $30{\times}30nm$ area requires bi-directional current flow enough to write a data by a drain induced barrier lowering (DIBL) under a reverse bias at N+/P (or P/N+ junction), and high current on/off ratio of 106. The SiGe materials are widely used in hetero-junction bipolar transistors, bipolar compensation metal-oxide semiconductors (BiCMOS) since the band gap of SiGe materials can be controlled by changing the fraction and the strain epilayers, and the drift mobility is increased with the increasing Ge content. In this work, N+/P/N+ SiGe material based junction provides that drive current is increased from 40 to $130{\mu}A$ by increased Ge content from 10~80%. When Ge content is about 20%, the drive current density of SiGe device substantially increased to 2~3 times better than Si-based junction device in case of 28 nm P length, which is sufficient current to operation of STT-MRAM.

  • PDF

Improvement of surgical haptic master device using cable-conduit and backlash compensation by smooth backlash inverse (케이블 컨듀잇 구조의 수술용 햅틱 마스터 장치의 개선과 smooth backlash inverse를 이용한 backlash 보정)

  • Choi, Woo Hyeok;Yoon, Sung Min;Lee, Min Cheol
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.1
    • /
    • pp.48-56
    • /
    • 2014
  • In robotic surgery, a surgeon checks only a surgical site of patient in the progress of surgery by vision and sound information. In order to solve this limited information, the haptic function is necessary. And haptic surgical robot is also necessary to design a haptic master device. The master device for laparoscope operation with cable-conduit was developed in previous research to give haptic function. It suggested a possibility of developing a master device by using the cable-conduit. However, it is very inconvenient to use. Therefore, this paper suggests a new mechanism design structure to solve the problems of the previous work by new forming a new master device. And it has proved that it's usability is better than previous one. Furthermore it has also experimented and analyzed that a backlash of new master device is compensated by smooth backlash inverse algorithm.

Optimal Design of Slider for Stable Flying Characteristics using $4{\times}1$ Near-field Probe Array

  • Jung, Min-Su;Hong, Eo-Jin;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil;Lee, Sung-Q;Park, Kang-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 2006
  • In the information storage development, the trend of the storage device is to increase the recording density. Among such an effort, near-field probe recording is spotlighted as a method of high increasing recording density. For the successfully embodiment of storage device, the actuating mechanism of near-field probe is essentially designed. In this paper, we suggest the slider similar with conventional HDD and design the slider using near-field probe for the purpose of applying the slider in order to control gap between probe and media. The most important object of slider design is to guarantee the flying ability and stability. For achievement of these design objects, we perform two step of optimal design process. The media is supposed to model as random displacement, which is only considered roughness of disk surface. The design slider is analyzed with dynamic state in assumed media. At this process, the optimal model is confirmed to stable flying stability.

  • PDF