• Title/Summary/Keyword: Deviation index

Search Result 551, Processing Time 0.03 seconds

A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

A Study on the Track Irregularity Index for the Estimation of Track Quality (궤도품질평가를 위한 궤도틀림 지표에 대한 연구)

  • 오지택;한승용
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.450-457
    • /
    • 2000
  • This paper establishes a scheme to estimate track quality using standard deviation and deterioration rate of track irregularities. To provide index of quality, standard deviation and deterioration rate of track irregularities are analyed. As an index, standard deviation and deterioration rate were applied to decision of corrective maintenance and replacement maintenance, respectively. Further, this paper proposes a basic scheme for a modernization of mechanize track maintenance that using MTT(Multiple Tie Tamper) and Ballast Cleaner.

  • PDF

A Multivariate Process Capability Index using Expected Loss (기대손실을 이용한 다변량 공정능력지수)

  • Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.4
    • /
    • pp.116-123
    • /
    • 2005
  • The traditional process capability indices Cp, Cpk, Cpm, $Cpm^+$ have been used to characterize process performance on the basis of univariate quality characteristics. Cp, Cpk consider the process variation, Cpm considers both the process variation and the process deviation from target and Cpm+ considers economic loss for the process deviation from target. In manufacturing industry, there is growing interest in quantitative measures of process variation under multivariate duality characteristics. The multivariate process capability index incorporates both the process variation and the process deviation from target or considers expected loss caused by the process deviation from target. This paper proposes multivariate capability index based on the expected loss derived from multivariate normal distribution.

Result Analysis according to Population Distribution Trends when Reagents are Changed (시약 변경 시 모집단 분포 추이에 따른 결과 분석)

  • Hye-Mi Park;Soo-Yeon Lim;Sun-Hee Yoo;Sun-Ho Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.55-61
    • /
    • 2023
  • Purpose In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.

  • PDF

A STUDY ON THE PROBABILISTIC PRODUCTION COST SIMULATION BY THE EFFICIENT LARGE DEVIATION METHOD (효율적인 LARGE DEVIATION 방법에 의한 발전 시뮬레이션에 관한 연구)

  • Song, K.Y.;Cha, J.M.;Kim, Y.H.;Oh, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.244-246
    • /
    • 1990
  • This paper describes the Large Deviation Method for computing the loss-of-load-probability (L.O.L.P.) index for a generating system. Also, we introduce a rule to prevent the initial value from diverging in Newton-Raphson method which we have to use to determine the value of t. By applying the Large Deviation Method to computing the L.O.L.P. index for some representative reliability test systems, it is verified that the Large Deviation Method is generally very accurate and very fast.

  • PDF

An Interpretation of Process Capability Index and Process Performance Index

  • Nam, Ho-Soo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.13 no.2
    • /
    • pp.285-294
    • /
    • 2002
  • The control chart is widely used tool for monitoring of the process. This paper deals with an interpretation of the process capability index(PCI) and process performance index(PPI) when the control chart is used for monitoring of the process. The main difference between the PCI and PPI is how we did estimate the process deviation. The PCI uses the within process variation and the PPI uses the total process variation, which is conceptually defined as sum of between process variation and within process variation. Easy interpretations of the PCI and PPI for field engineers are described. And some new approaches to interpretation of the process capability and performance index may be useful in early stabilization of new process.

  • PDF

Development of Expected Loss Capability Index Considering Economic Loss (경제적 손실을 고려한 기대손실 능력지수의 개발)

  • Kim, Dong-Hyuk;Park, Hyung-Geun;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.4
    • /
    • pp.109-115
    • /
    • 2013
  • Process Capability Index (PCI) is useful Statistical Process Control (SPC) tool that is measure of process diagnostic and assessment tools widely use in industrial field. It has advantage of easy to calculate and easy to use in the field. $C_p$ and $C_{pk}$ are traditional PCIs. These are only considers of process variation. These are not given information about the characteristic value does not match the target value of the process. Studies of this process capability index by many scholars actively for supplement of its disadvantage. These studies to evaluate the capability of situation of various field has presented a new process capability index. $C_{pm}$ is considers both the process variation and the process deviation from target value. And $C_{pm}{^+}$ is considers economic loss for the process deviation from target value. In this paper development of new process capability index that is Taguchi's quadratic loss function by applying the expected loss. And check the correlation between existing traditional process capability index ($C_{pk}$) and new one. Finally, we propose the criteria for classification about developed process capability index.

Refractive Index and Excess Volume for Diisopropylamine + Isomeric Butanol Mixtures in terms of Nakata and Sakurai model

  • Kumari, Kavitha;Maken, Sanjeev
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.644-651
    • /
    • 2021
  • Alkyl amines are widely used in various industries. Nowadays these are also used in CO2 capture technology because amines react with CO2 and remove it from the flue gas. To make the amines more compatible towards this technology, physico chemical properties may be altered by mixing with other solvents. In the present report, we measured the refractive properties of pure diisopropylamine (DIPA) (1) + isomeric butanol (2) at 298.15 K to 308.15 K. The 𝚫n values were positive for DIPA + n-butanol or sec-butanol or isobutanol or tert-butanol mixtures. The measured data was correlated with Redlich-Kister equation. The excess molar volume data were predicted from refractive index data using Nakata and Sakurai model. The experimental data were also predicted by various correlations, and the prediction capability of these correlations was reported through standard deviation. Further, the deviation in refractive index (𝚫n) data was interpreted by the consideration of specific molecular interactions between DIPA and isomeric butanol.

A note on $C^{pk}$ index estimation using fuzzy numbers

  • Hong, Dug-Hun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.20-21
    • /
    • 2002
  • Recently, Lee[European J. Operational Research 129(2001) 682-688] calculated standard deviation of fuzzy numbers in order to obtain the membership function of the process capacity index (PCI) $C^{pk}$. In this note, we show that his result is not valid.

Systematic Review of the Diagnosis of Pelvic Deviation for Chuna Manual Therapy (추나치료에 적용된 골반변위 진단법에 대한 체계적 문헌고찰)

  • Lee, Jun-Seok;Park, Kyeong-Won;Kim, Hyun-Tae;Park, Sun-Young;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.32 no.2
    • /
    • pp.83-94
    • /
    • 2022
  • Objectives This systematic review aimed to analyze research about pelvic deviation diagnosis for Chuna manual therapy (CMT) and to review the diagnosis methods, indices, and results of diagnosis. Methods Ten electronic databases were systematically searched up to January 4th 2022. Clinical studies and reviews containing pelvic deviation diagnosis for CMT or using CMT as a treatment of pelvic deviation were selected and evaluated. CMT diagnosis in clinical studies and reviews were isolated and analyzed by 2 independent reviewers. Results Thirteen clinical studies and three reviews were included in the evaluation. X-ray analysis and manual testing were the two main methods used in CMT diagnosis of pelvic deviation. For manual testing in clinical studies, leg length insufficiency testing was the most frequently used measurement index and the most common diagnostic results were anterior and posterior rotation. In the X-ray analysis, Obturator foramen and femur head line were the most frequently used measurement index and the most common diagnostic results were anterior rotation and posterior rotation. Conclusions The systematic review found that manual testing and X-ray analysis were mainly used for the diagnosis of pelvic deviation in CMT among clincial and review articles. As there was little research about diagnosing pelvic deviation in CMT and any existing research presented only low standards of evidence, further research should be updated with using a more standardized approach.