• Title/Summary/Keyword: Deviation Index

Search Result 571, Processing Time 0.029 seconds

Diagnosis and constitutional and laboratory features of Korean girls referred for precocious puberty

  • Kim, Doosoo;Cho, Sung-Yoon;Maeng, Se-Hyun;Yi, Eun Sang;Jung, Yu Jin;Park, Sung Won;Sohn, Young Bae;Jin, Dong-Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.12
    • /
    • pp.481-486
    • /
    • 2012
  • Purpose: Precocious puberty is defined as breast development before the age of 8 years in girls. The present study aimed to reveal the diagnosis of Korean girls referred for precocious puberty and to compare the constitutional and endocrinological features among diagnosis groups. Methods: The present study used a retrospective chart review of 988 Korean girls who had visited a pediatric endocrinology clinic from 2006 to 2010 for the evaluation of precocious puberty. Study groups comprised fast puberty, true precocious puberty (PP), pseudo PP, premature thelarche, and control. We determined the height standard deviation score (HSDS), weight standard deviation score (WSDS), and body mass index standard deviation score (BMISDS) of each group using the published 2007 Korean growth charts. Hormone tests were performed at our outpatient clinic. Results: The PP groups comprised fast puberty (67%), premature thelarche (17%), true PP (15%), and pseudo PP (1%). Advanced bone age and levels of estradiol, basal luteinizing hormone (LH), and peak LH after gonadotropin-releasing hormone stimulation testing were significantly high in the fast puberty and true PP groups compared with the control group. HSDS, WSDS, and BMISDS were significantly higher in the true PP group than in the control group (P<0.05). Conclusion: The frequent causes of PP were found to be fast puberty, true PP, and premature thelarche. Furthermore, BMISDS were significantly elevated in the true PP group. Therefore, we emphasize the need for regular follow-up of girls who are heavier or taller than others in the same age group.

Effects of drumming exercise on the autonomic nervous system in overweight women (드러밍 운동이 과체중 여성의 자율신경계에 미치는 영향)

  • Jeong In Kwon;Jae Hoon Lee;Joon Yong Cho;Yoo Sung Oh
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.219-232
    • /
    • 2024
  • The aim of this study was to explore the impact of body mass index (BMI) and drumming exercise on autonomic nervous system function in adult women. Ten adult women (aged 30-50) were divided into two groups based on their BMI: a normal BMI group (Low BMI, LBMI < 23 kg/m2) and an overweight BMI group (High BMI, HBMI > 23 kg/m2). Both groups participated in a drumming exercise program, consisting of 50-minute sessions, three times a week, for a duration of 8 weeks. Body composition and heart rate variability were assessed before and after the 8-week exercise period. Heart rate variability was evaluated using linear analysis in the time domain and frequency domain. Additionally, non-linear analysis was conducted using a Poincaré plot. The autonomic nervous system index was determined by measuring parasympathetic nervous system index and sympathetic nervous system index. Following the 8-week intervention, the HBMI group exhibited a significant decrease in weight (p=0.034), BMI (p=0.044), body fat mass (p=0.032), and waist circumference (p=0.013) compared to the LBMI group. Furthermore, the HBMI group demonstrated significant increases in RMSSD (p=0.018) and TP (p=0.033) in linear analysis, as well as SD1 (p=0.018) in non-linear analysis and PNS Index (p=0.040) compared to the LBMI group. RMSSD, SD1, and PNS Index serve as indicators of parasympathetic nervous system activity in linear and non-linear analyses, respectively. These findings indicate that drumming exercise significantly enhances autonomic nervous system function in overweight women.

A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System (전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구)

  • Cho Jin-Young;Mun Jun-Chul;Jung Chang-Kyoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.622-631
    • /
    • 2005
  • In this paper, we reduce 'over and under deviation' and 'over and under testing' which have a cause of uncertainty in electromagnetic radiated immunity test. We analyze continued measurement method of field uniformity and propose new estimate method having the minimum uncertainty condition. We test comparison in 4 anechoic chambers and analyze FDI(Field Deviation Index) which is the minimum deviation excess 6 dB on fields. We obtain that the proposed test method improve 1.193 dB than domestic standard(KN 61000-4-3) and 0.017 dB than international standard (IEC61000-4-3) in every frequency. In the test result 'over and under testing point' have 926 point at every field area and have 118 point at center uniform area. These result know that proposed measurement method have 10 point less at every field area and 9 point less at center uniform area than continued measurement method. The proposed test method have few point more than continued measurement method. Therefore, we confirmed that the proposed test method have the minimum uncertainty in electromagnetic radiated immunity test.

Development of Deduct Value Curves for the Pavement Condition Index of Asphalt Airfield Pavement (아스팔트 공항포장의 PCI 산출을 위한 공제값 곡선 개발)

  • Lee, Kang-Jin;Seo, Young-Chan;Cho, Nam-Hyun;Park, Dae-Wook
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.37-44
    • /
    • 2013
  • PURPOSES: This study is to develop the deduct value curves for the calculation of pavement condition index of asphalt airfield pavement. METHODS: To develop the deduct value curves of asphalt airfield pavement, panel rating was conducted to decide the pavement condition based on pavement distress type, severity, and density. RESULTS: Results show that standard deviation of deduct values by panel rating is increased at higher severity level and as damage density increases. The deduct value of alligator cracking show the highest. CONCLUSIONS: The deduct value curves based on panel rating could be used without existing problems which were occurred in Shahin's method.

Construction of an Economic Sentiment Indicator for the Korean Economy

  • Moon, Hye-Jung
    • The Korean Journal of Applied Statistics
    • /
    • v.24 no.5
    • /
    • pp.745-758
    • /
    • 2011
  • An Economic Sentiment Indicator(ESI) is a composite indicator of business survey indices(BSI) and consumer survey indices(CSI). The ESI designed to reflect economic agents' (this includes producers and consumers) overall perceptions of economic activity in a one-dimensional index. The European Commission has published an ESI since 1985. This paper demonstrates the construction of an ESI for the Korean economy. The BSI and CSI components (having a high correlation and a leading feature with respect to GDP) are selected to construct the ESI and they are aggregated using a weighted average and then scaled to have a long-term average of 100 and a standard deviation of 10. Thus values greater than 100 indicate an above-average economic sentiment and vice versa. The newly constructed Korean ESI that extends to January 2003 shows a good tracking performance of GDP and adequately reflects the overall perception of economic activity.

ON THE LONG-TERM VARIABILITY OF SOUTHERN OSCILLATION INDEX

  • Jin, Young-Hoon;Kawamura, Akira;Jinno, Kenji;Iseri, Yoshihiko
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2003.05a
    • /
    • pp.151-158
    • /
    • 2003
  • Recently, there has been considerable interest in the influence of El Nino/Southern Oscillation (ENSO) on a global scale. ENSO has been measured by a simple index called Southern Oscillation Index (SOI). The statistical characteristics of SOI have been also focused to reveal the influence of ENSO. The SOI trend shows that El Nino events are generally getting stronger and more frequently occurring than La Nina events. However, the variation of SOI has varied significantly in a long-term. The SOI values are computed using the mean value and its standard deviation of the base period from 1951 to 1980. In the present study, the different base periods are applied to compute the SOI values and the influence of the different base periods is investigated in detail to reveal the long-term variation of SOI From the results, we could conclude that the present SOI should be carefully considered as a criterion to judge whether the El Nino and La Nina events are occurring.

  • PDF

Monte-Carlo Simulation and measuring for Error Analysis of 3-axis SCARA Robot using Observability (관측성을 이용한 3축 SCARA Robot의 오차분석을 위한 Monte-Carlo simulation 및 측정)

  • Ju, Ji-Hun;Chung, Won-Jee;Kim, Jung-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 2008
  • This paper aims at finding out dominant robot configurations with maximal position errors, which can be attributed to the parameter errors, by using Monte-Carlo simulation for error analysis of a 3-axis SCARA(Selective Compliance Assembly Robot Arm) type robot. In particular, the Monte-Carlo simulation is used for virtually measuring on the position errors, instead of physical measurement. In order to measure the observability of the model parameters with respect to a set of robot configurations, we propose the observability index which is defined as the product of singular values for error propagation matrices. Thus the index can be used for discriminating dominant robot configurations from a set of simulated ones in conjunction with standard deviation of positional errors, This paper analyzed error by robot positional error.

Biometric analysis hand parameters in young adults for prosthetic hand and ergonomic product applications

  • Gkionoul Nteli Chatzioglou;Yelda Pinar;Figen Govsa
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.172-182
    • /
    • 2024
  • This study aimed to evaluate the superficial anatomy, kinesiology, and functions of the hand to reveal its morphometry and apply the findings in various fields such as prosthetic hand and protective hand support product design. We examined 51 young adults (32 females, 19 males) aged between 18-30. Hand photographs were taken, and measurements were conducted using ImageJ software. Pearson correlation analysis was performed to determine the relationship between personal information and the parameters. The results of the measurements showed the average lengths of finger segments: thumb (49.5±5.5 mm), index finger (63.9±4.1 mm), middle finger (70.7±5.2 mm), ring finger (65.5±4.8 mm), and little finger (53.3±4.3 mm). Both females and males, the left index finger was measured longer than the right index finger. The right ring finger was found to be longer than the left in both sexes. Additionally, length differences between fingers in extended and maximally adducted positions were determined: thumb-index finger (56.1±6.2 mm), index-middle finger (10.7±4.1 mm), middle-ring finger (10.8±1.4 mm), and ring-little finger (25.6±2.7 mm). Other findings included the average radial natural angle (56.4°±10.5°), ulnar natural angle (23.4°±7.1°), radial deviation angle (65.2°±8.2°), ulnar deviation angle (51.2°±9.6°), and grasping/gripping angle (49.1°±5.8°). The average angles between fingers in maximum abduction positions were also measured: thumb-index finger (53.4°±6.5°), index-middle finger (17.2°±2.6°), middle-ring finger (14.3°±2.3°), and ring-little finger (32.1°±7.0°). The study examined the variability in the positioning of proximal interphalangeal joints during maximum metacarpophalangeal and proximal interphalangeal flexion, coinciding with maximum distal interphalangeal extension movements. The focal points of our observations were the asymmetrical and symmetrical arches formed by these joints. This study provides valuable hand parameters in young adults, which can be utilized in various applications such as prosthetic design, ergonomic product development, and hand-related research. The results highlight the significance of considering individual factors when assessing hand morphology and function.

Availability of Statistical Quality Control of Nuclear Medicine Blood Test Using Population Distribution (모집단 분포를 이용한 핵의학 혈액검사의 통계적 품질관리의 유용성)

  • Cheon, Jun Hong;Cho, Eun Bit;Yoo, Seon Hee;Kim, Nyeon Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2016
  • Purpose The importance of quality control by the error to a minimum, which for the purpose of enhancing the reliability of the examination is not be emphasized excess. Currently, most nuclear medicine laboratory are conducting the internal and external quality control, and they are applying the Levey-Jennings or Westgard Multi-Rules by using the commercialized quality control materials. The reliability of the nuclear medicine blood test which affects the diagnosis of patients and the treatment policy is being secured through this quality control activity. Therefore, researchers will evaluate the utility of the statistic quality control using the population distribution of the nuclear medicine blood test conducted targeting the checkup examinees by the additional technique of the reliability improvement. Materials and Methods A statistic analysis was performed about 12 items of the nuclear medicine blood test targeting 41,341 peoples who used the health screening and promotion center in Asan Medical Center from January, 2014 to December, 2014. The results of 12 items of the nuclear medicine blood test was divided into the monthly percentage of three groups: within reference values, over reference, and under reference to analyze the average value of the population distribution, standard deviation, and standard deviation index (SDI). Results The standard deviation of the population distribution mostly showed a result within ${\pm}2SD$ in all groups. However, When the standard deviation of the population distribution represented a result over ${\pm}2SD$, it was confirmed SDI was showing a result of SDI > -2 or SDI > 2. As a result of analyzing the population distribution of 12 items(AFP, CEA, CA19-9, CA125, PSA, TSH, FT4, Anti-Tg-Ab, Anti-TPO-Ab, Calcitonin, 25-OH-VitD3, Insulin) of the nuclear medicine blood part basic test, when SDI of the monthly percentage which deviated from the reference values was over ${\pm}2.0$, CA19-9 September was 2.2, Anti-Tg-Ab may was 2.2, Insulin January was 2.3, Insulin March was 2.4. It was confirmed these cases were attributed to the abnormality of the test reagent (maximum combination rate of isotope reagent declined) and the decline of the test response time. Conclusion The population distribution includes the entire attribute which becomes the study object. It is expected the statistic quality management using the population distribution which was conducted targeting the checkup examinees by dividing into three groups: within reference values, over reference, and under reference by means of this characteristics will be able to play a role of complementing the internal quality control program which is being carried out in the laboratory.

  • PDF

Approximate Analytical Expression of the Laser Wavelength Distribution Incurred by the Grating Period Fluctuation in QWS-DFB Lasers (QWS-DFB 레이저에서 회절격자 주기의 랜덤 변이에 따른 주모드 파장 분포의 해석적 근사식)

  • Ha, Seon-Yong;Kim, Sang-Bae;Na, Sang-Sin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.9
    • /
    • pp.616-623
    • /
    • 2001
  • Effects of the grating period fluctuation on the wavelength distribution have been studied by an effective index transfer matrix method in quarter wavelength shifted (QWS) DFB lasers. The wavelength distribution is expressed by a probability density that is an analytical function of the correlation coefficient and normalized standard deviation of the grating period fluctuation. The probability density function of wavelength distribution is shown to be nearly Gaussian, and its standard deviation increases with normalized standard deviation of the grating period fluctuation, and decreases with the negative correlation between adjacent half-periods.

  • PDF