• 제목/요약/키워드: Deterioration factors

검색결과 650건 처리시간 0.032초

상수관로의 노후도 영향인자 및 가중치 산정에 관한 연구 (Estimation of Deterioration and Weighting Factors in Pipes of Water Supply Systems)

  • 김응석;김중훈;이현동
    • 상하수도학회지
    • /
    • 제16권6호
    • /
    • pp.686-699
    • /
    • 2002
  • The purpose of this study is to estimate deterioration factors and weighting factors in pipe network which each local self-governments takes rehabilitation and replacement work present time. Deterioration factors in pipe network are able to effected of specific province or location related with water supply. Most of water supply pipes are laid under the ground, it is hard to quantify deterioration degree of water system. Moreover, the timing and economic limitation and insufficient information on the spot survey gives a difficulty to look over how old water supply system is. Accordingly, this study collects and analyses five data as the laying environment, visual analysis, analysis of soil contents, analysis of pipe material, and questionary survey data in water pipe of A city. The deterioration factor estimates 14 factors with excavation and experimental analysis and 9 factors without excavation and experimental analysis. Also, the weighting factors are estimated by using the multiple linear regressions and the linear programming. The estimated deterioration factor and weighting results are compared the analysis result of visual, pipe material, and soil contents with the Probabilistic Neural Network Model. Consequently, the model results of estimated 9 factors in this study and 14 factors show the 1-2% difference. The result show that the proposed model could be used to decide the deterioration condition of pipe line with real excavation and experimental analysis.

계층적분석과정을 이용한 상수관로의 노후도 평가를 위한 항목별 가중치 산정 (Estimation of Deterioration Assessment for Weighting Factors in Pipes of Water Supply Systems Using Analytic Hierarchy Process)

  • 김응석
    • 한국방재학회 논문집
    • /
    • 제8권5호
    • /
    • pp.15-21
    • /
    • 2008
  • 본 연구의 목적은 현재 지방자치단체에서 수행하는 상수관로 개량 및 교체 사업시 상수관로의 노후도 평가를 위한 항목별 가중치를 산정하는 것이다. 상수도시스템에 상수관로의 노후도 항목은 지역 및 위치, 토지이용 등의 특성에 영향을 받을 수 있다. 본 연구에서는 국내외 자료를 바탕으로 국내 실정에 맞는 노후도 항목 16개를 선정하였다. 또한, 노후도 항목별 세분화된 가중치 산정을 위해 실무업체를 선정하여 해당 전문가들을 대상으로 노후도 항목별 중요도에 대한 설문을 실시하였다. 설문 조사 방법으로는 델피법을 이용하여 이 결과를 바탕으로 계층적분석과정(AHP)을 적용하여 노후항목별 가중치를 산정하였다. 분석결과 국내 실무에 적합한 16개 결함항목별 점수배점표를 작성하여 명확한 판단기준을 마련하였으며 관거 개량사업에 있어서 복잡한 의사결정 문제들에 대한 활용 가능성을 제시하였다.

철근콘크리트 구조물의 열화 진단시스템 개발 - 열화요인 진단을 중심으로 - (Development of Deterioration Diagnosis System for the R/C Structures - Mainly on Cause of Deterioration -)

  • 이장화;박홍석;유영찬;김도겸;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.243-248
    • /
    • 1994
  • The purpose of this study is to develop Deterioration Diagnosis System for the Reinforced Concrete Structure which can be used preliminary in determining the factors causing deterioration by simple inspection and mapping of the indicators of deterioration. Total 29 items compromising material, structural and constructional factors causing deterioration were considered in this system. Also the indicators of deterioration were subdivided into 54 items such as concrete crack pattern and steel corrosion etc. Each indicator of deterioration was quantatified by allocating and giving grade to each item which has extra weight according to its conscquence. Satisfactory results were obtatined by applying this Diagnosis system to the indicators of deterioration in ref. [3]. Further research was required on the indicators of deterioration in construction site to enhance the field applicability of this system.

  • PDF

Clarification the Current Situation of Deterioration and Its Causes of Modernization Heritage Built with Bricks in Japan: A Case Study of Long-Term Monitoring Investigation at Sarushima Battery, Yokosuka, Japan

  • Fukami, Risako;Matsui, Toshiya;Kawamoto, Mayumi
    • 보존과학회지
    • /
    • 제38권4호
    • /
    • pp.265-276
    • /
    • 2022
  • A long-term monitoring investigation at Sarushima Battery (Kanagawa, Japan), which is one of the modernization heritages was conducted from 2017.06 to 2020.12. The investigation of the temperature and relative humidity (RH), measurement of the amount of brick decay, and X-ray diffraction analysis of the brick decay was conducted to understand in detail the environment in which the historical brick structure, the state of deterioration, identify the factors of deterioration. Furthermore, it was discussed whether the suitability of these investigation methods for assessing the status, identifying the level of deterioration and the factors that led to deterioration at the historical brick heritages. It was found that the brick deterioration at the site progressed especially in two periods: in April, and from June to August. These periods coincided with the period when the RH inside the structure decreased, and the Toyo-gumi bricks were in the process of absorbing moisture. Several different types of salts were detected in brick decay, especially thenardite, which is considered highly hazardous and destructive during periods when the amount of brick decay increased. Therefore, the RH in the structure and the salts present in the bricks were identified as one of the factors in the deterioration of the bricks at the site. The methods used in this study are appropriate as the initial survey methods for investigating the current conditions and identifying the causes of deterioration because it is possible to understand the environment within the modernization heritages, grasp the details of deterioration progression, and identify the characteristics of deterioration progression and its factors through long-term investigation using the simple methods.

학교시설물의 노후화 현상 및 지진.화재.풍수해의 피해에 대한 사례 조사연구 (A investigation study on the site analysis damaged by disaster and deterioration reason of school facilities)

  • 윤유혁;신이철;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.21-26
    • /
    • 2008
  • We investigate the various factors such as earthquake, fire, flood and deterioration factors such as carbonation, salt attack, freezing thawing, alkali-aggregate reaction effects on the school facilities. As the consequence of this study we can see that there are very relative relation between deterioration factors and disaster factors. It is the aim of this study to investigate the site analysis damaged by disaster and deterioration factors of school facilities.

  • PDF

극저온 하에서의 일정 온도유지가 콘크리트의 열화에 미치는 영향 (The Influence of Storage at Very Low Temperatures on the Deterioration of Concrete)

  • 한상묵;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.667-672
    • /
    • 2002
  • Concrete cooled to very low temperature cyclically is deteriorated by ice formation in micro-pores. Although the factors to the deterioration are various, storage at very low temperature is mentioned as one of the factors. In practice, storage of cryogenic structure is kept at very low temperatures, and as such, it is important to take into consideration the influence of storage at such low temperature on the deterioration of concrete. Thus, in this study, the influence of storage on the deterioration of concrete at minimum temperatures taking into consideration the different W/C and air content.

  • PDF

철근콘크리트조 아파트구조물의 노후도 실태조사에 의한 노후화 요인 분석.평가에 관한 연구 (A Study on the Analysis and Evaluation of Deterioration Factors for the Structure of Reinforced Concrete Apartment According to Actual Condition Survey)

  • 강석표;김규용;권영진;정성철;이덕찬;송병창;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.391-396
    • /
    • 1998
  • The concrete structures are hardly ever built under ideal conditions. So many defects may occur for a various reasons such as unsuitable and defective materials, construction methods, poor workmanship, particular structural form and prevailing weather conditions. Some structural form can greatly increase the risk of occurrence of defects. Therefore we investigated the actual condition of the deterioration factors for reinforced concrete apartment, which was composed of 85 apartments with various building ages in different regions with five evaluation the deterioration factors of apartment building to establish the overall evaluation system of deterioration degree for reinforced concrete apartment in Korea.

  • PDF

적외선 탐사기를 이용한 외벽열화 진단시스템의 평가기법 향상에 관한 연구 (A Study on the Improvement of Evaluation Method of Diagnosis-System for Exterior-Wall Deterioration by Infrared Thermography)

  • 김무한;권영진;강석표
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권2호
    • /
    • pp.185-190
    • /
    • 1999
  • It is difficult to estimate for deterioration of exterior wall by infrared thermography, because of amount of infrared-ray radiation effected by environmental factors such as temperature properties of materials, the outside air and the amount of solar radiation. Therefore we measured the distribution of temperature by times in the same reinforced-concrete structure in order to reduce problems, occasioned by environmental factors, then we analyzed physical influence factors of the infrared thermography. It is the aim of this study to suggest basic data with regard to method of estimation-system for deterioration of exterior wall in reinforced-concrete structures.

  • PDF

농수로 구조물의 내구성 저하 요인 (Deterioration Factors of Agricultural Hydraulic Structures)

  • 조성현;김진만;김기동;고만기;김종옥
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.647-650
    • /
    • 1999
  • Deterioration of agricultural hydraulic structures(AHS), which are under harsh environmental conditions, is more sever than other ordinary structures. To investigate the deterioration factors of AHS, various physical and chemical analyses are performed. The porosity of AHS increases more rapidly than ordinary structures because they are subject to frequent water permeation and water-soluble materials are easily emitted to surface area. Thus, AHS are tend to be damaged by freezing and thawing more easily due to the increase of water containment inside concrete.

  • PDF

Evaluation of Maintenance Coating Materials for Steel Bridges

  • Lee, Chan-Young;Cheong, Haimoon;Kim, Ok-Sun
    • Corrosion Science and Technology
    • /
    • 제4권5호
    • /
    • pp.207-210
    • /
    • 2005
  • Coating performance of various coating systems including chlorinated rubber and epoxy/urethane used most for steel structures of highway in Korea, was evaluated by exposing test specimen to complex deterioration factors such as ultraviolet ray, moisture, freeze-thaw cycle and salt. Deteriorated specimens were evaluated by chalking and rust grades according to ASTM, and measurement of color differences and adhesion. In overall coating performances such as corrosion resistance, photochemical stability, and adhesion, ceramic/ urethane, moisture-curable urethane/ urethane, etc. were superior. As for other coating materials tested in this study, superior materials against certain deterioration factors may be inferior against other factors. Accordingly, in order to select suitable maintenance coating materials for the use, it is thought that investigation of suitability through experiment should precede selection of materials, especially for unusual coatings or paints.