• Title/Summary/Keyword: Deterioration factor

Search Result 397, Processing Time 0.029 seconds

Novel technique for preventing make up deterioration using performance materials

  • Miyazawa, Masakazu;Nishikata, Kazuhiro;Mohri, Kunihiko
    • Proceedings of the SCSK Conference
    • /
    • 2003.09b
    • /
    • pp.370-378
    • /
    • 2003
  • MFD (Make up Film Deterioration) is a gradual deterioration of applied make up and is a common problem experienced by most foundation users. Our investigation revealed that for 64% of all make up users MFD is their greatest consern is using foundations. Known that the primary cause of MFD is sebum secretion. We observed that the length of time prior to onset of MFD in people who produce high level of sebum varies significantly from person to person. This suggests that other factors besides quantity of sebum production can affect MFD. Control over this factor would, we believe, be key to developing longer-lasting makeups. We studied the relationship between MFD and skin surface conditions. Our study revealed that furrows on the skin surface affect MFD significantly. Sebum reaches the skin surface from sebaceous glands and flows along furrow on the skin. If there are many deep furrows, it takes longer for sebum to overflow. But if the furrows are few or shallow, sebum quickly overflows and spreads over the skin surface where it can degrade the make up film. Therefore even when the volume of sebum produced is the same, the rate of MFD will be different depending on the number and shape of the furrows. A longer-lasting foundation could be produced by matching personal skin condition, but this would be very difficult because individual variations in texture are very large. Therefore we approached the problem by attempting to impose sebum resistance in under make up and foundation. We have developed two new materials and make up products based on our theory. A new fluoroalkyl acrylate-methacrylates copolymer designed for incorporation in under make up is extremely sebum resistant and sweat proof. Another new acrylate polymer designed for inclusion in foundation absorbs sebum and changes to a solid. Usage tests confirm it is possible to reduce MFD by using under make up and foundation which incorporate our new materials to cover where skin furrows are few or shallow

  • PDF

Structural Performance Investigation for the Reinforced Concrete Frames Deteriorated by the Reinforcement Corrosion (철근부식에 의한 철근콘크리트골조의 구조성능분석)

  • Choi, Se-Woon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.5
    • /
    • pp.563-570
    • /
    • 2015
  • The existing research on the damage detection method for building structures has considered the damages from the excessive loadings such as the earthquake. However, the structural performance of building structures could be reduced due to the deterioration based on the chloride, carbonation during the long-term time. Thus, to effectively manage the healthiness of structures, the deterioration influences on the structures should be checked. In this study, the corrosion of rebars by the chloride is considered as the deterioration factor. To consider the structural performance reduction of the corroded rebars, the yield strength, cross-sectional area, rupture strain of rebars and the compressive strength of cover concrete based on the corrosion level are estimated. These properties of rebars and cover concrete are used for the procedure to evaluate the structural performance reduction of structural member level and the building level. The moment-curvature analysis is performed to evaluate the structural performance reduction of structural member level. Also, the eigenvalue analysis and the pushover analysis are performed to investigate the natural period and mode shape and the strength and deformation performance of buildings, respectively.

Variable Emission Factor Prediction Model for An Air Quality Assessment of Transportation Projects (교통사업의 대기질 평가를 위한 가변적 배출계수 예측모형)

  • Lee, Gyu-Jin;Choe, Gi-Ju;Yu, Jeong-Hun;O, Se-Chang
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.6
    • /
    • pp.117-128
    • /
    • 2011
  • In this study, a model is developed to predict emission factors, which aims to objectively evaluate the impact of transport projects on air quality. Two emission prediction models for the years of 2015 and 2030 are developed using the historical trends in vehicle aging and vehicle deterioration factors. The analysis results show that the emission factors under the operating speed of 30km/h for the year 2030 are 5~37% and 2~83% less than those used in the current studies for passenger cars and bus/trucks, respectively. The statistically validated experiment results demonstrate the applicability of the proposed model to evaluation of the impact of transport policies on air quality.

Sensitivity analysis of RPLS inventory model with price dependent demand linearly under order-size-dependent delay in payments in a two-stage supply chain (주문량에 따라 종속적으로 외상거래기간이 허용되는 상황 하에 선형수요함수를 고려한 RPLS 재고모형의 퇴화율에 따른 민감도분석)

  • Shinn, Seong-Whan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.577-582
    • /
    • 2022
  • Credit transactions are used as a means of price discrimination from competitors in order for suppliers to increase customer demand. In particular, in the case of a two-stage supply chain consisting of a supplier, a retailer, and a customer, the deferral of payment for goods allowed by the supplier is a means of reducing the inventory investment cost of the retailer. Retailers have the opportunity to discount the selling price while anticipating an increase in end-customer demand through the reduction of the inventory investment cost. In view of the fact that such trade credit is provided for the purpose of increasing demand as a means of discrimination from competitors, it may be more general that the credit transaction period is allowed flexibly according to the transaction volume. In particular, in the case of deteriorating products, the credit transaction period given according to the order volume is a factor that increases the order volume of the retailer, but product deterioration can be a limiting factor in the increase in the order volume. The deterioration rate actually plays an important role in determining the inventory policy of the retailer. Therefore, in this paper, the effect of such deterioration rate on the inventory policy of retailer is analyzed.

A Development of Soundness Evaluation Index for Poor Appearance Distribution Concrete Poles (외관불량 배전용 콘크리트전주 건전도 평가지표 개발)

  • Wong, Yoon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.35-44
    • /
    • 2014
  • This study was to secure the safety of poor appearance distribution concrete poles effectively and to reduce the replacement costs of them by developing a soundness evaluation index. The researcher of this study investigated poor appearance types of concrete pole, collected 53 of test samples, and tested pole strength. As a result of strength test, only 17 percent of poor appearance concrete poles were below 2.0 of safety factor spec. As results of multiple regression analysis, it is verified that surface air void, horizontal crack, net-shaped crack, elapsed year, vertical crack, and deterioration in concrete compressive strength have statistically negative effects on safety factor of concrete poles in a significant level. The researcher set up a soundness evaluation index by using multiple regression equation, and suggested that poor appearance concrete poles should be replaced or reinforced only in case of soundness evaluation score of 150 or above.

Air-void Analysis of Deteriorated Jointed Concrete Pavement Using Concrete Core Specimen (코어 시편을 이용한 열화된 줄눈콘크리트 포장의 공극구조 분석)

  • Choi, Pan-Gil;Jeong, Beom-Seok;Yun, Kyong-Ku;Kwan, Soo-Ahn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.253-254
    • /
    • 2009
  • This study was conducted to estimate deterioration reason of jointed concrete pavement. Image analysis tests were performed according to ASTM C 457 using concrete core specimens. Durability factors were estimated according to spacing factor, which is related with air content and air-void information. Test results show that spacing factors of most specimens were estimated above 250$\mu$m so that investigated concrete pavement has the problem of freeze and thawing resistance.

  • PDF

Evaluation of Impact Factor on Ballast Track in Subway using Field Test (지하철 자갈도상 케도의 충격계수 평가)

  • Kang, Kee-Dong;Park, Yong-Gul;Choi, Jung-Youl
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.6 s.37
    • /
    • pp.784-791
    • /
    • 2006
  • This paper presents the test results to evaluate the healthiness of the ballast in subway. The test includes the dynamic load test in servicing Line the screen classification test of aggregates and the wear test. From the results, the aspect and the property of the ballast are evaluated. The dynamic load tests explain the relationship between the deterioration of the ballast and the fluctuation of loads. The assessment of impact factor based on the field test results in a good property of test blocks is proposed.

Evaluation of Impact Factor on Ballast Track in Subway using Field Test (지하철 자갈도상 궤도의 충격계수 평가)

  • Park, Kyun-Seo;Son, Chol-Su;Yun, Jong-Kyeong;Choi, Jung-Youl;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.484-493
    • /
    • 2006
  • This paper is presented the test results to evaluate the healthiness of the ballast in subway. The test includes the dynamic load test in servicing Line the screen classification test of aggregates and the wear test. From the results, the aspect and the property of the ballast are evaluated. The dynamic load tests the relationship between the deterioration of the ballast and the fluctuation of loads. The assesexplain sment of impact factor based on the field test results in a good property of test blocks is proposed.

  • PDF

An Improved Method for the Evaluation of Load Carrying Capacity of Existing Bridges (교량 구조물의 개선된 내하력 평가기법)

  • Oh, Byung-Whan;Kim, Ki-Su;Shin, Ho-Song;Lee, Woong-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.53-64
    • /
    • 1997
  • Recently, safety evaluation of structures has received great concern in this country. One major problem in safety evaluation is that the results are often quite different depending upon evaluation authority. This is mainly due to arbitrary selection of various modification factors when employing allowable stress method for safety evaluation, The purpose of the present study is, therefore, to establish a rational method to determine the modification factors, especially the stress modification factor and the deterioration modification factor based on visual examination. It is thought that the proposed method yields a rational and consistent result for safety evaluation and may efficiently be used for realistic evaluation of load capacity of bridge structures.

  • PDF

The Long-term Operating Evaluation of the Grid Connected Photovoltaic System (태양광발전시스템의 장기운전에 의한 성능특성 분석)

  • Kim, Eui-Hwan;Kang, Seng-Won;Kim, Jae-Eon
    • New & Renewable Energy
    • /
    • v.7 no.2
    • /
    • pp.28-35
    • /
    • 2011
  • Recently, photovoltaic systems have been devolved into much larger systems up to MW-scale. Photovoltaic industry participants give their focus on power generation capability of photovoltaic modules because their benefits can be decided from the amount of generation. The information on long-term performance change of photovoltaic modules helps to estimate the amount of power generation and evaluate the economic cost-benefits. Long-term performance of a PV system has been analyzed with operation data for 12 years from 1999 to 2010. In the first year, the amount of yearly power generation was 57.7 MWh with 13.2% capacity factor. In 2007, the amount of yearly generation was 44.3 MWh with 10.14% capacity factor, and in 2010, the amount was decreased down to 38.1 MWh with 8.7% capacity factor. The result means that long-term capacity factor has been 4.5% decreased for 12 years and that the amount of generation has been decreased 34.0% for 12 years which is 2.8 % per year. The latter capacity factor has been decreased faster than 0.20%, the average rate for 10 years. The performance decrease of the PV system is meant to be accelerated. The decrease of performance and utilization is due to aged deterioration of photovoltaic modules and lowering conversion efficiency of PCS.