• Title/Summary/Keyword: Deterioration evaluation

Search Result 742, Processing Time 0.028 seconds

Factor Analysis of Deterioration in Namhansanseong Yeojang (남한산성 여장 손상원인 분석)

  • Chung, Kwang-Yong;Lee, Sang-Ok;Yang, Hee-Jae
    • Journal of architectural history
    • /
    • v.25 no.1
    • /
    • pp.59-68
    • /
    • 2016
  • There are many reasons of damage in Namhansanseong Yeojang. Lots of damage types are observed in each Yeojang. There are many types of damage factors but major damage factor is breakage by freezing and thawing. So Conduct non-destructive evaluation about damage factors in Namhansanseong Yeojang to analysis weathering factors in Yeojang by measuring directional microclimate. The study will pave the way for conservation management in Namhansanseong by suggesting the conservation calendar about weather condition and damage factors.

Complex Environmental Degradation Resistance Performance Evaluation Method of Membrane Waterproofing Systems for Underground Concrete Structure Joint (지하 콘크리트 구조물 조인트에 대한 멤브레인 방수시스템의 복합 환경 대응 성능 평가 방법)

  • Oh, Kyu-Hwan;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.44-45
    • /
    • 2017
  • There are various national standards designed to test the physical properties of waterproofing materials for the respective countries based on each of their environmental parameters, variables and requirements. The problems of these standard systems can be outlined in the following: (1) there are too many test methods and criteria to satisfy in order assess one waterproofing membrane system, and (2) there is currently no known method to compile the separate testing results to provide a comprehensive report on waterproofing system durability. This paper outlines and compares the performance testing results of various types of asphalt waterproofing membrane systems and discusses the potentials of a complex environmental deterioration analysis method.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of Waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • Kang, Hyo-Jin;Kwon, Shi-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs, to improve durability of structure. This study separately examined physical and chemical specific of quality liguid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

An Experimental Approach for Characteristic Rattle Noise Considering the Deterioration Condition of Cockpit Module Materials in the Vehicle (자동차 칵핏 모듈용 시편 소재의 열화 조건을 고려한 이음(Rattle) 발생 특성에 관한 시험적 고찰)

  • Yang, Jeongmin;Yi, Chulhyun;Cho, Jinho;Lee, Wonku;Woo, Changsu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.796-799
    • /
    • 2014
  • It is treated more seriously than ever as the customer requirements are becoming a high-quality and diversification. Among the various elements to affect customer's evaluation of automobile quality, BSR(buzz, squeak, rattle noise) are considered to be a mostly contributing factor. Rattle Noises in cockpit modules are one of the major concerns mentioned above. Recently, measurements of the BSR noise between the parts that make up the products from the perspective that the structural causes. For structures that make up material has not been any consideration of the BSR noise characteristics. The aim of this study is to clarify the characteristics of noise occurrence in vehicle cockpit module that consist of plastic material after measuring noise by rattle special testing instrument.

  • PDF

A Study on a Performance evaluation for Quality Liguid Siliceous of waterproof agent (액상형 규산질계 침투성 방수재의 성능평가에 관한 연구)

  • 강효진;권시원;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.63-67
    • /
    • 2003
  • There are many factors that generate the early deterioration of the concrete structure. As the one of the representative factors, we can think an invasion of the water, air and so on. The water and air invade in inside void along the capillarity and they become the cause that the durability like corrosion of layer department due to freezing and thawing, inside steel frame corrosion, and so on blacks. Therefore with covering permeability covering waterproofing material of fluid condition in outer wall, intercepting the deterioration factor due to the infiltration of water from outside and for salt damage of concrete layer department, freezing damage and neutralization, it needs to improve durability of structure. This study separately examined physical and chemical specific of quality liquid siliceous of waterproofing material. Therefore as this applys the construction site, it improves the durability of concrete structure. Further this presents the application plan from the construction market against the new material.

  • PDF

Evaluation of Chloride Ion Binding Capacity of Hardened Portland Cement Paste Containing Hydrotalcite (경화된 하이드로탈사이트 혼입 포틀랜드 시멘트 페이스트의 염소이온 고정능력 평가)

  • Han, Jae-Do;Lee, Yun-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.27-28
    • /
    • 2018
  • Deterioration of reinforced concrete structures due to salt corrosion is a phenomenon that can be easily seen, and the main reason for deterioration is chloride ion. Therefore, researches are actively conducted to control chlorine ion penetration worldwide. The purpose of this study is to evaluate the chloride ion fixation capacity of Portland cement paste containing Hydrotalcite. For this purpose, cement paste containing 0%, 2.5%, and 5% of Hydrotalcite was sealed and cured for 28 days, and the cured cement paste was crushed. Chloride ion solution was prepared at a concentration of 0.5M using NaCl, and the powdered cement paste was reacted for a specific time in aqueous chloride ion solution. After the reaction, the concentration of the chloride ion aqueous solution was measured using a silver nitrate potentiometric titrator, and the reacted cement paste was analyzed using XRD and FT-IR.

  • PDF

Condition Evaluation of Concrete Bridge Decks using CPR (레이더를 이용한 콘크리트 교량의 바닥판 상태평가)

  • Suh, Jin-Won;Rhee, Ji-Young;Lee, Il-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the Ground Penetrating Radar(GPR) was tested to evaluate the condition of concrete decks. Test results obtained by CPR were compared with values measured from drilled cores and damage mapping by the visual survey. It is shown that GPR can provide highly accurate measurements of layer properties of concrete decks and can map areas of deterioration in bridge decks by dielectric constants. The deck condition can be grouped into categories of "good" or "distressed". The ground penetrating radar data shows promise for producing rapid and accurate condition assessment for bridge decks. And these data can be used to evaluate highway bridge condition and make cost-effective bridge deck rehabilitation by accurately estimating the quantity of deteriorated concrete.

  • PDF

Harmonic evaluation of 100 kHz ultrasonic pulse transmitted through concrete exposed to high temperature (고온에 노출된 콘크리트를 투과한 100kHz 초음파의 고조파 평가)

  • Hwang, Eui-Chul;Park, Ki-Hong;Pyeon, Su-Jeong;Eu, Ha-Min;Nam, Jeong-Soo;Kim, Guy-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.183-184
    • /
    • 2022
  • In this study, harmonics of 100 kHz ultrasonic pulse transmitted through concrete exposed to high temperature were evaluated. Concrete exposed to high temperatures deteriorates its mechanical properties. In ultrasonic pulse, the fundamental wave was attenuated by the deterioration of the concrete. In addition, it was possible to confirm the occurrence of harmonics. It is thought that the fundamental and harmonics of ultrasonic pulse greatly affected by the internal structure of concrete.

  • PDF

Evaluation of Performance and Reliability of a White Organic Light-Emitting Diode(WOLED) Using an Accelerated Life Test(ALT) (가속수명시험(ALT)을 이용한 WOLED의 성능 및 신뢰성 평가)

  • Moon, Jin-Chel;Park, Hyung-Ki;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.13-19
    • /
    • 2012
  • The purpose of this study is to extract the major factors related to the deterioration mechanism of white organic light-emitting diodes(WOLED) by performing accelerated testing of temperature, voltage, time, etc., and to develop an accelerated life test(ALT) model. The measurement results of the brightness of the WOLED exhibited that their average brightness tended to increase as the operating voltage increased and that the half-life period of the brightness appeared after approximately 400 hours when the operating voltage was 20V and the ambient temperature was $85^{\circ}C$. It could be seen that although the WOLED showed comparatively the same brightness when the initial acceleration began after the operating voltage was applied to it, its brightness changed excessively after the WOLED's thermal storage had been made. In addition, it was observed that the half-life period was reduced as the ambient temperature and applied voltage increased. The strength of the WOLED which had been maintained in the range of visible light at the maximum load was reduced by the deterioration of the organic light emitting material due to the influence of the operating voltage and temperature, and the reduction of emitted light was small at low voltage and temperature. It could be seen that the failure of the WOLED during the ALT was caused by wear due to load accumulation over time, and that Weibull distribution was appropriate for the life distribution and acceleration was established between test conditions. From the WOLED analysis, it is thought that factors influencing the brightness deterioration are voltage, temperature, etc., and that comprehensive analysis considering discharge control, dielectric tangent margin, etc., would further increase the reliability.

An Investigation on the Quality of High-Strength Shotcrete and the Long Term Durability using Combined Deterioration Test (고강도 숏크리트의 품질평가와 복합열화시험을 통한 장기내구성 검토)

  • Ma, Sang-Joon;Kim, Dong-Min;Choi, Jae-Seok;Ahn, Kyung-Chul;Kim, Sun-Myung;Ko, Jin-Kon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.906-915
    • /
    • 2006
  • In this study, Field test was performed using high-quality additions and accelerators to obtain the improvement of the strength on domestic shotcrete and quality test based on EFNARC was performed. In addition, Deterioration test that combined the Freezing-thawing and Carbonation was also performed in order to investigate a long-term durability of high-strength shotcrete. As a result of field test, a promotion ratio of early strength is $90\sim97%$ in case of using alkali-free accelerators. And a compressive strength of shotcrete using Micro-silica fume was $45.2\sim55.8MPa$ and the flexible strength was $5.01\sim6.66MPa$, so a promotion ratio of strength was $37\sim79%$, $17\sim61%$ respectively. It was showed that increment effect of strength by the Micro-silica fume replacement of $7.5\sim10%$ for cement mass was remarkable. It was also realized that application of Micro-silica fume to shotcrete reduced deterioration and improved a long-term durability of shotcrete.

  • PDF