• 제목/요약/키워드: Deterioration Diagnosis

검색결과 345건 처리시간 0.034초

전기설비사고예방을 위한 온라인진단기술 개발의 경제성 분석 (A Study on Economic Analysis of Development of On-line Diagnosis Technique for Preventing Electrical Accidents)

  • 김한상;김광호
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.313-318
    • /
    • 2014
  • In the last couple of decades industrialization and technological development has not only increase in the scale of electrical facilities and it has become more and more complicated and diversified. Furthermore, fires in the electrical transformers, like those that have knocked out power in the country in the past years, are likely to become more common as utility systems begin to show their age. The importance of preventing electrical accidents can never be overemphasized and for this reason, supply of on-line diagnosis system combining information and communication technology(ICT) for the customer's electrical facilities has been increasing recently. The major advantage of on-line diagnosis system is that the device's potential problems could be detected early before a serious deterioration or breakdown occurs. In this paper, We estimated the benefit from the investment in the right of present value of sales, success rate of commercialization regarding R&D investment for development and commercialization of on-line diagnosis technology targeting customer electrical facilities. As a result, the net value added of 29.7 billion won and the increased profit by roughly 7.52 precent are expected.

도시철도차량 전선의 열화진단 평가기준 (Evaluation Standards to Diagnosis Cables in Urban Railway Vehicles)

  • 임재윤;이종필;이대종;지평식;강성화;김형철
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.268-274
    • /
    • 2010
  • Urban rail transit brings the benefits of various aspects of society. With the advent of fast and large trains, however, risk and scale of accidents have increased. Despite the fact that there is various safety features built into the modern metros, train faults happen from time to time. Especially, as urban railway vehicles in Korea have become deterioration rapidly, more advanced diagnosis methods are required to prevent various accidents. In this paper, we present diagnosis method for electrical wires to guarantee secure driving and authenticity more accurately in urban railway vehicles. Although there are kinds of conventional methods based on insulation resistance measurement and withstand test, it is extremely difficult to effectively diagnose obsolete equipments such as electrical wires and cables not new ones. This study is focused on development of diagnosis method and establishment of evaluation standard for electrical wires in urban railway vehicles.

3상 170 kV 가스절연개폐장치(GIS)의 사고 원인 분석 및 예방 대책 (Analysis of the Causes of Accidents Related to 3 Phase 170 kV Gas Insulated Switchgears(GIS) and Preventive Measures)

  • 최충석
    • 한국안전학회지
    • /
    • 제26권4호
    • /
    • pp.41-46
    • /
    • 2011
  • The purpose of this paper is to analyze the causes of accidents related to the 3 phase 170 kV gas insulated switchgear of a power system collected from accident sites to secure data for the prevention of similar accidents and provide important points of view regarding diagnosis for the prevention of accidents involving gas insulated switchgears. The analysis results of the causes of accidents involving gas insulated switchgears showed deformation of the manipulation lever installed at the S-phase, disconnection of the insulation rod connection, melting of the upper conductor, a damaged tulip, damage to the lower spacer and the spacer at the breaker, etc. It is believed from this result that the potential for accidents has expanded due to accumulated energy as a result of repeated deterioration. The carbonization depth of a GIS was formed near the screw (T2, T3) used to secure the lower pole of the S-phase tulip. It is not known what has caused the screws to be extruded and melted. However, it is thought that an unbalanced electromagnetic force, micro-discharge, surface discharge, etc., have occurred at that point. In addition, even though 16 years have passed since its installation, there was no installation defect, act of arson, accidental fire, etc. General periodical inspection and diagnosis failed to find the factors causing the accidents. As a system contained in a closed metal container, it has a high risk factor. Therefore, it is necessary to design, install and operate a GIS in accordance with the standard operational procedure (SOP). In addition, it is necessary to apply conversion technology for periodical SF6 gas analysis and precision safety diagnosis. It is expected that tracking and managing these changes in characteristics by recording the results on the history card will provide a significant accident prevention effect.

가공 배전선로 진단시스템 프로그램 개발 (Development of overhead distribution line diagnosis system program)

  • 정동현;이덕진
    • 스마트미디어저널
    • /
    • 제12권5호
    • /
    • pp.81-87
    • /
    • 2023
  • 전력계통에서 안정적인 전력공급을 하는 고압 가공 배전선로의 사고 발생으로 생활의 불편과 더불어 기업의 생산 차질을 초래하게 된다. 22.9[kV] 고압 가공 배전선은 평소 비, 눈, 바람 등에 의한 피해나 감전방지 등의 신뢰성 및 안정성의 향상을 목적으로 하고 있다. 이에 가공 배전선로의 부식으로 인한 전선의 도전율을 저하시키거나 인장강도가 저하되어 단선 사고를 미연에 방지하기 위하여 평소에 점검과 보수를 통하여 미래의 예기치 못한 사고를 미리 방지하여야 한다. 배전선로의 부식으로 인한 열화진단을 하기 위하여 전선에 진단시스템(계측기)를 설치하여 전선의 상태를 모니터링한다. 측정된 데이터를 ZigBee 무선통신으로 지상의 관리자가 받아 진단시스템 프로그램을 통하여 진단시스템의 제어와 측정된 데이터 및 촬영된 사진을 통하여 가공 배전선로의 상태를 파악하여 육안 검사 방법과 더불어 전선의 수명을 예측하는 프로그램을 개발하였다.

무선 데이터 통신을 이용한 주상 및 지상 변압기 진단 장치 개발 (Development of Diagnosis Device for Pole and Pad Transformer using Wireless Data Communication)

  • 윤용한;민경래;최도혁;김재철
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.85-92
    • /
    • 2000
  • 본 논문에서는 간이 열화 측정 탑촉자를 갖고 무선 데이터 통신의 이용으로 배전용 변압키(주양/지상)을 감사 진단할 수 있는 장치를 개발하였다. 개발한 장치는 크게 건이 열화 측정 탐촉자, 유위 측청 정치, 열화 측정 장치 및 송.수신부(무선 자료 수집 정치, 원격 제여 장치)로 구성되어 았다. 제안한 장치의 효용성 빛 적용성을 검증 하기 위해서 기존의 정밀급 계측 장치와의 비교.분석 실험을 수행하였으며, 그 상관 관계를 검토한 결과, 상대적인 선형 관계가 있음을 확인하였다. 띠라서 본 논문에서 제안한 감시 및 진단 장치를 주상/지상 변압기에 설치하면 간편하면서도 경제적으로 수많은 배전용 변압기의 신뢰성 있는 감시 진단이 가능하리라 기대된다.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

프랙탈 특성과 음향방출 계측법을 이용한 LDPE 시료에서의 트리잉 파괴진단에 관한 연구 (A Study On the Diagnosis Breakdown Using Fractal Characteristics and the Method of Acoustic Emission in Low Density Polyethylene)

  • 윤헌주;박재준;신승중;최재관;김성홍;김재환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1758-1760
    • /
    • 1997
  • Automatic detection system to detect acoustic emission pulse and fractal dimension were developed, to observe tree deterioration phenomena in LDPE. The purpose of our work are to use acoustic emission system and fractal dimension and to investigate the treeing phenomena in polymeric insulation under applied AC voltage 11[kV] with an artificial needle-shaped void(1.5[mm]) using the above system. We analyzed and phase angle-acoustic emission pulse amplitude-deterioration time ($\Phi$-AEA-t) pattern and phase angle-acoustic emission pulse number-deterioration time($\Phi$-AEN-t) pattern using statistical operators such as skewness, fractal dimension. In this paper show that the correlation of $\Phi$-AEA-t, $\Phi$-AEN-t, fractal dimension using regression analysis by the method of least squares can be used to predict the breakdown just before the breakdown occurs.

  • PDF

고압회전기 절연열화진단의 현장적용기술연구 (A Study on Site Application Techniques for Insulation Reliability of Rotating Machine)

  • 김길용;조경해;김택수;한상욱;이현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.286-291
    • /
    • 1991
  • Most of the failures of rotating machine are stator coil insulation failures. The insulation diagnostic testing for high voltage motors and generators are only megger test and P. I Test which is applied DC voltage until now. But it was impossible to judge insulation deterioration status of high voltage rotating machinery by above testing. In other words, even though the megger measurement values are fairly high, they used to be failed from time to time. Therefore in order to excute reliable and detailed diagnosis of insulation deterioration for rotating machinery, the tangent delta test, the alternating current test and the partial discharge test shall be applied to the insulation diagnostic testing on site.

  • PDF

인공적 침상보이드의 갭길이 변화에 따른 음향방출 특성 (Characteristics of acoustic emission according to variation gap length on artificial needle shape void)

  • 박재준;김상남
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권4호
    • /
    • pp.495-503
    • /
    • 1995
  • As lengthen gap leng of artificial needle shape void 0.24.rarw.1.5[mm]), the amplitude of AE(Acoustic Emission) pulses was enlarged and number of pulses be generated was few. The longer gap length of void, the shorter breakdown time. As a result of this, I found that existen of void in insulation mate was fatal deterioration of insulation. According to phase angle of applied voltage, time being void was scattered largely in region of phase angle of pulses of origination in phase angle of applied voltage. The result will be used to analysis of void diagnosis.

  • PDF

유입 변압기 진단을 위한 유중 열화 측정 센서의 개발 (Development of Deterioration Detecting Sensor in Oil for Diagnosis of Oil-Filled Transformers)

  • 민경래;윤용한;김영춘;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.128-130
    • /
    • 2000
  • This paper develops the deterioration detecting sensor in oil to monitor and diagnose oil-filled transformer more effectively. The on-line inspection of the oil-filled transformers used the temperature, the changes of the capacitance, the $tan{\delta}$ in oil. This sensor was designed based on the concentric cylindrical type so that it could be placed inside of the oil-filled transformer. And comparing to the existing system, it was proven to be appropriate. Establishment of the proposed sensor helps to build the confidence in monitoring of the oil-filled transformers.

  • PDF