DOI QR코드

DOI QR Code

Evaluation Standards to Diagnosis Cables in Urban Railway Vehicles

도시철도차량 전선의 열화진단 평가기준

  • 임재윤 (대덕대학 전기과) ;
  • 이종필 (충주대학교 전기공학과) ;
  • 이대종 (충주대학교 전기공학과) ;
  • 지평식 (충주대학교 전기공학과) ;
  • 강성화 (충청대학 소방안전과) ;
  • 김형철 (한국철도기술연구원 전철전력연구실)
  • Received : 2010.06.17
  • Accepted : 2010.08.14
  • Published : 2010.09.01

Abstract

Urban rail transit brings the benefits of various aspects of society. With the advent of fast and large trains, however, risk and scale of accidents have increased. Despite the fact that there is various safety features built into the modern metros, train faults happen from time to time. Especially, as urban railway vehicles in Korea have become deterioration rapidly, more advanced diagnosis methods are required to prevent various accidents. In this paper, we present diagnosis method for electrical wires to guarantee secure driving and authenticity more accurately in urban railway vehicles. Although there are kinds of conventional methods based on insulation resistance measurement and withstand test, it is extremely difficult to effectively diagnose obsolete equipments such as electrical wires and cables not new ones. This study is focused on development of diagnosis method and establishment of evaluation standard for electrical wires in urban railway vehicles.

Keywords

References

  1. 전기케이블의 전기적특성시험방법(KS C IEC 60885-1)
  2. 전기설비기술기준, 지식경제부 고시, 2010, 1. 8
  3. Hanmin Lee, Gildong Kim, Sechan Oh, Gilsoo Jang, Saehyuk Kwon, "Fault analysis of Korea AC electric railway system," Electrical Power Systems Research, vol. 76, pp. 317-326, March. 2006. https://doi.org/10.1016/j.epsr.2005.08.001
  4. XLPE전력케이블의 DC내전압 시험법에 의한 열화 판정법에 관한 연구, 서울산업대학교 전기공학과 석사학 위논문, 신명호, 2006.
  5. N. C. Wang, C. F. Chi, T. Y. Guo, "Leakage current test and study of room temperature vulcanizing coatings for outdoor high voltage porcelain insulators", Conf. Power System Technology, Perth, WA, Dec., 2000.
  6. D. G. Byun, H. T. Shin, W. J. Kim, J. Y. Shin, J. W. Hong, "Insulation deterioration diagnosis on ultra high voltage power cables," presented at the 7nd Int. Conf. Dielectric Materials, Nagoya, Japan, 2003.
  7. M. Kruger, R. Feurstein, A. Filz, "New very low frequency methods for testing extruded cables," presented at Conf. Electrical Insulation, Toronto, Canada, 1990.
  8. IEEE Power Engineering Society, "IEEE Std 400, IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems", IEEE, 2001.
  9. IEEE Power Engineering Society, "IEEE Std 400.1, IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5kV and Above with High Direct Current Voltage", IEEE, 2007.