• Title/Summary/Keyword: Deterioration Condition

Search Result 717, Processing Time 0.024 seconds

Secondary Mineral Formation and Concrete Deterioration Caused by Certain Environmental Conditions (특정환경조건하에서의 콘크리트 내 이차광물생성과 그에 수반된 성능저하현상)

  • 이효민;황진연;진치섭;이진성;전쌍순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.651-656
    • /
    • 2003
  • Durability of concrete is possibly related to externally-induced chemical attacks in addition to internally-induced deterioration. Externally-induced chemical attacks can be derived from various sources according to environmental conditions under which concrete structures are existing. The present study investigates the characteristic concrete deterioration and formation of secondary minerals by external chemical attacks under certain environmental condition. Petrographic microscope, SEM, EDAX, XRD analyses were conducted to identify secondary mineral formation and micro-structural analyses.

  • PDF

COBDA-An Expert System for Concrete Bridge Deterioration Assessment (COBDA-콘크리트 교량의 노후화를 평가하는 전문가 시스템)

  • ;Cabrera
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.532-539
    • /
    • 1996
  • Existing assessment methodologies present a considerable problem because of fuzzy situation of deterioration mechanism of concrete bridges; namely, qualitative, subjective or inconsistent. This paper discusses current assessment methods in aspect of uncertainty. The expert system, COBDA, is developed for consistent and fast assessment of deteriorantion of concrete bridges. Briefly introduced in this paper are the structure of expert system and several methodologies for decision making of deterioration situation and providing repair option. COBDA is configured by PROLOG for logic approach and expert system shell based on Bayesian subjective probability. The methodologies are illustrated and discussed by comparison of condition assessment results in a case study.

  • PDF

Estimation of Deterioration and Weighting Factors in Pipes of Water Supply Systems (상수관로의 노후도 영향인자 및 가중치 산정에 관한 연구)

  • Kim, Eung-Seok;Kim, Joong-Hoon;Lee, Hyun-Dong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.16 no.6
    • /
    • pp.686-699
    • /
    • 2002
  • The purpose of this study is to estimate deterioration factors and weighting factors in pipe network which each local self-governments takes rehabilitation and replacement work present time. Deterioration factors in pipe network are able to effected of specific province or location related with water supply. Most of water supply pipes are laid under the ground, it is hard to quantify deterioration degree of water system. Moreover, the timing and economic limitation and insufficient information on the spot survey gives a difficulty to look over how old water supply system is. Accordingly, this study collects and analyses five data as the laying environment, visual analysis, analysis of soil contents, analysis of pipe material, and questionary survey data in water pipe of A city. The deterioration factor estimates 14 factors with excavation and experimental analysis and 9 factors without excavation and experimental analysis. Also, the weighting factors are estimated by using the multiple linear regressions and the linear programming. The estimated deterioration factor and weighting results are compared the analysis result of visual, pipe material, and soil contents with the Probabilistic Neural Network Model. Consequently, the model results of estimated 9 factors in this study and 14 factors show the 1-2% difference. The result show that the proposed model could be used to decide the deterioration condition of pipe line with real excavation and experimental analysis.

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

Study on Performance and An Exhaust Emission by Bio-Diesel Deterioration and Engine Load Rate at Heavy-Duty Diesel Engine (대형디젤기관에서 바이오디젤 열화와 엔진부하에 따른 배출가스특성 및 성능에 관한 연구)

  • Park, Man-Jae;Kim, Mi-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.56-63
    • /
    • 2007
  • Modern diesel vehicle has to comply with the EURO IV, V regulation with low level of particulate matter and smoke emission Moreover, emission standards of each countries are becoming stringent in advanced countries such as USA and Europe. Because Bio-diesel is similar to diesel fuel, it is essential to judge the environmental and health effects deriving from the use of Bio-diesel in diesel engine. The deterioration characteristics of emission in accordance with aging vehicles must be regulated for Bio-diesel. Therefore, under 1200 driving hours, 220,000km driving distance condition and full load, the deterioration characteristics of emission were estimated. We could reduce sulfur contents of fuel, particulate matter and smoke emission by using Bio-diesel and conform the influence of engine performance, emission, and fuel consumption by Bio-diesel deterioration

On-Site Conservation of the Underwater Objects Excavated (해저 발굴유물의 현장 보존처리)

  • Moon, Whan-Suk;Kim, Byung-Keun;Yang, Soon-Seok
    • 보존과학연구
    • /
    • s.25
    • /
    • pp.133-150
    • /
    • 2004
  • Once the object has been excavated at underwater condition, it should be subjected to condition that may cause its deterioration. Therefore, it is important that the object immediately keeps stable environment. It means that the object was excavated at underwater and it exposed the deterioration condition, as soon as possible it was not dried on surface, especially metallic and organic material. Iron objects is particularly notorious for rapid disintegration that it kept wet or stored in a stable environment. Ceramics, glass and stone were handled carefully that it prevented physical damage by mishandling. Organic materials of wood, leather, rope, bone must not be allowed to dry out because the creaking, shrinking and warping are well known disintegration. Therefore objects is basis of keeping stable condition in on-site and then it will have to pass through a detailed conservation process in the laboratory.

  • PDF

Estimation of Insulation Diagnosis and Dielectric Strength in 6.6 kV Motor Stator Windings (6.6 kV 전동기 고정자 권선의 절연진단과 절연내력 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.6
    • /
    • pp.780-785
    • /
    • 2014
  • To assess the deterioration condition of stator insulation, diagnostic and AC dielectric strength tests were performed on five high voltage (HV) motors (2,000 HP, 6.6 kV) for boiler feed-water pump (BFP). Two HV motors for BFP were installed per unit. Following the long term rewinding program, the diagnostic test was performed on five 6.6 kV motors during the planning maintenance period. After completing diagnostic test, AC dielectric strength test was done on the stator windings of HV motors. The AC dielectric strength test was conducted at 15 kV for one minute. Dielectric strength test and diagnostics test results confirmed that the stator insulation was judged to be in serviceable condition in the five 6.6 kV motors.

A study on the Analysis of Insulation Aging for Generator stator windings (수력발전기 고정자권선의 절연열화 분석)

  • Byun, D.G.;Oh, B.K.;Kang, D.S.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2072-2074
    • /
    • 2005
  • This test was performed to assess the insulation condition of the stator winding of 3.45kV hydro generator in insulation deterioration condition which was due to long service period(30years) since installed We extracted 12 stator wingdings from the hydro generator core, cut the stator windings into three parts(Middle winding part, slot winding part, end wingding part), and evaluated the insulation condition to know the deterioration condition of each parts. This insulation diagnostic tests include AC current, dissipation factor, and partial discharg test.

  • PDF

Analysis of Test Results for Small Dipstick-Gage-Type Engine-Oil-Deterioration-Detection Sensor (딥스틱게이지형 소형 엔진오일열화감지센서의 시험결과 분석)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.156-167
    • /
    • 2014
  • This paper presents the test results of small dipstick-gage-type engine-oil-deterioration-detection sensor. The measured sensor signal characteristics for the capacitance and temperature are analyzed. The engine oil deterioration condition correlates with the electrical property of the dielectric constant that comprised with physical properties such as TAN (Total Acid Number), TBN (Total Base Number) and viscosity. Several problems encontered during the test of the sensor system are improved. The results of vehicle tests show that the capacitance signal is stable after the engine stops. Therefore, the sensor should start measuring the parameters for monitoring the engine oil condition after the engine stops. The engine is considered to be in a stopped state if the difference between the maximum and minimum values of the oil capacitance measured every 1 min is below 0.02 pF. The key test results in this paper will help in the development of an engine oil change warning algorithm.

Influence of Cultivation Condition and Harvest Time on the Storage Stability of Fresh Ginseng Individually Packaged in a Soft Film (재배조건 및 채굴시기가 연포장재 필름으로 개별포장한 수삼의 저장성에 미치는 영향)

  • 손현주;김은희;성현순
    • Journal of Ginseng Research
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2001
  • The influence of cultivation condition and harvest time on the storage stability of the fresh ginseng (50g) individually packaged in a soft film bag (ONY/LDPE/L-LDPE; 200$\times$300 mm, 90㎛) was investigated. When the fresh ginsengs were divided into four groups of direct-planted ginseng on the paddy soil(PD), transplanted ginseng on the upland(UT) and each group was stored at 25$\^{C}$ for 40 days, the quality deterioration rate was the highest in PD group while PT, UD and UT groups exhibited similar quality patterns from each other. When each group was stored at 10$\^{C}$, the quality deterioration rate was also the highest in PD group and the other three groups exhibited similar quality patterns from each other till 90 days passed after storage. However, the quality deterioration rate of UT group was 54% which was higher than UD group or PT group 180 days after storage. When the fresh ginseng harvested between September of 1997 and October of 1998 was individually packaged with the soft film and stored at 25$\^{C}$ for 12 days, the quality deterioration rate was the lowest in the group harvested in October while relatively high in the groups harvested between July and September.

  • PDF