• Title/Summary/Keyword: Deterioration Characteristics

Search Result 979, Processing Time 0.032 seconds

Properties of the SHOT PATCH Mortar a Wet System for Small Bore Tunnels (소구경 터널에 사용되는 SHOT PATCH용 모르타르의 특성)

  • 정민철;전용희;정종익;박길수
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.6
    • /
    • pp.121-128
    • /
    • 1999
  • The SHO PATCH System Mortar is a mortar shotcreting system which uses fairly small machine and equipment, and is applied for shotcrete tunnel linings, in particular for small bore tunnels of aqueducts by the TBM(Tunnel Boring Machine) method, and for reparing tunnels suffering from spring water and deterioration. This study shows the characteristics of the new mortar shotcreting system, the SHOT PATCh System Mortar, which exhibits excellent shotcrete performance.

Deterioration of Concrete Columns under Sea-Water and Strengthening Analysis (해수중 콘크리트 기둥의 열화 및 보강성능해석)

  • 김규엽;송하원;변근주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1169-1174
    • /
    • 2001
  • In this study, the behavior of deteriorated concrete columns under sea-water before and after strengthening with glass fiber composite and the change of behavior by the deterioration of strengthening material are analyzed. In the analysis, the characteristics of concrete deteriorated in sea-water, preloading effect, and corrosion of steel are considered. The result of analysis is verified by the comparison with the experimental data. Using constitutive equations of the concrete and corroded steel, load-moment interaction curves of both deteriorated and strengthened concrete column are derived.

  • PDF

A Study on Deterioration in Polymer Insulating Material at Cryogenic Temperature (극저온중의 고분자 절연재료의 열화연구)

  • 김현희;김영석;김상현;최효상;조광욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.311-315
    • /
    • 1996
  • This Paper is to discribe the ac treeing deterioration in Polyethylenetherphthalate (PET) at various temperature. The AC tree was investigated at 77K using L$N_2$. The experimental results show that V-t characteristics was an inverse proportion to temperature. The progress of tree initiation and growth were also to temperature.

  • PDF

Bond Strength Characteristics of Bonded Concrete Overlay (접착식 콘크리트 덧씌우기의 부착강도 특성 분석)

  • Park, Jong Won;Kim, Young Kyu;Lee, Seung Woo;Han, Seung Hwan
    • International Journal of Highway Engineering
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2013
  • PURPOSES : Bonded concrete overlay is a favorable maintenance method since the material properties are similar to existing concrete pavements. In addition, bonded concrete overlay has advantage of structural performance since the overlay layer and the existing pavement perform as a monolithic layer. It is important to have suitable bond strength criteria to secure the performance of bonded concrete overlay. This study aimed to investigate the factors influencing bond strength characteristics between existing concrete pavement and overlay material. METHODS: Bond strength between overlay and existing pavement are measured and analyzed for various conditions such as the type of overlay materials, compressive and flexure strength of overlay and existing pavement, and deterioration status of existing pavement. RESULTS: The strength of overlay material does not significantly influence the bond strength. The overlay of ultra-rapid hardening cement generally gives low bond strength. However, ultra rapid hardening polymer modified concrete gives robust bond strength. The deterioration of existing concrete significantly decrease the bond strength. CONCLUSIONS: Bond strength of bonded concrete overlay highly depends on condition of existing concrete pavement rather than overlay material.

The Stability of Heat Deterioration of Pressure Sensitive Tapes for Repairing Documents(I) (Physiochemical Characteristics of Imported or Manufactured Tapes Repairing Documents) (종이 기록물 보수용 안전 테이프의 열화 안정성 연구(I) (수입 및 국내 시제품 물리 화학적 특성 비교))

  • Shin, Joung-Soon;Yoo, Sun-Kyun;Kang, Young-Reet
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.2
    • /
    • pp.1-11
    • /
    • 2010
  • The physicochemical characteristics, adhesion power, and conservation of imported tapes repairing documents that consisted of adhesive, carrier, and masking were investigated. Materials related to pressure sensitive adhesive produced in domestic companies were examined also. And then, the performance evaluation of prototype manufactured in our laboratory was undertaken. Both the pressure sensitive tapes were compared. The polyacrylate of adhesive agents such as polyacrylate, starch, Glue, and PVA of imported tapes was best. The adhesion strength, power, reversibility, and stability (deterioration) of imported tapes were analyzed. By comparing results of imported tapes, two adhesive agents were selected finally. The carriers of imported tapes are made of one of papers, cotton sheets, and felts. Major carrier material was a paper. The jutes, conifers, and hardwoods were main ingredient of papers. The durability of Hangi($18{\pm}2g/m^2$) was one and half times superior to imported one.

Seismic Fragility Analysis of Reinforced Concrete Shear Walls Considering Material Deterioration (재료의 열화를 고려한 철근콘크리트 전단벽의 지진 취약도 분석)

  • Myung Kue, Lee;Jang Ho, Park
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.6
    • /
    • pp.81-88
    • /
    • 2022
  • It is necessary to better understand the effect of age-related degradation on the performance of reinforced concrete shear walls in nuclear power plants in order to ensure their structural safety in the event of earthquakes. Therefore, this paper studies seismic fragility of the typical shear wall in nuclear power plants under earthquake excitation Reinforced concrete shear wall is composed of wall, horizontal and vertical flanges. Due to characteristics of its geometry, it is difficult to predict the ultimate behavior of shear wall under earthquake excitation. In this study, for more realistic numerical simulation, the Latin Hyper-Cube (LHC) simulation technique was used to generate uncertain variables for the material properties of concrete shear walls. The effects of crack, characteristics of inelastic behavior of concrete, and loss of cross section were considered in the nonlinear finite element analysis. The effects of aging-related deterioration were investigated on the performance of reinforced concrete shear walls through analysis of undegraded concrete shear walls and degraded concrete shear walls. The resulting seismic fragility curves present the change of performance of concrete shear wall due to age-related degradation.

Long-Term Preservation Measures of Paper Records of Special Preserving Organization (특수 보존 기관의 종이 기록물 장기 보존 대책)

  • Shin, Jong-Soon;Lee, Jae-Soo
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2012
  • This study is Long term preservation measures which is closely related to preserving paper records, record condition evaluation, preservation measure and is conducted as follows. As for Means to Evaluate the Deterioration and Damaged Conditions of Records, research and analysis has been made on the contamination and deterioration examples such as damage, dry, stapler, metal, contamination, acidification which are the characteristics of paper record damage types. The of Paper record is one of the key procedures to evaluate the record material and its physi-chemical status in many criteria and to suggest the best preservation method. Between 1970 and 2000, the main record materials was fine paper and OMR paper along with partly newspaper and coarse paper, whereas the main recording material was ball point pen. Overall damage and deterioration status is, for record materials between 1940 and 1960, high deterioration was found and in urgent need for preservation measure and more damages are caused by tapes, staplers and metals. As for records after 1970, there is light deterioration but needs preservation process. There are approximately 3 million records produces before 2000, and assuming that there are 30 pages per record and that 30% has been damaged or deteriorated, 27 million pages are subject to preservation process. Among damaged or deteriorated records, there are large number of records impossible to go through deacidification process so manual preservation and restoration process is necessary as well. Securing manpower having preservation and restoration skills as well as preservation equipment(deacidification process, preservation and restoration) is in urgent need.

Assessment of the Deterioration of Large-Diameter Pipe Networks (I) : Development of an Assessment Model (대구경 관로의 노후도 평가 연구(I) : 평가모형 개발)

  • Kim, Eung-Seok;Lee, Seung-Hyun;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.482-487
    • /
    • 2014
  • The purpose of this study (I) is to provide a new methodology for evaluating deterioration of buried pipe networks for the large-diameter old pipe improvement project currently performed by K-water. To develop a new assessment model for large-diameter pipe deterioration, this study has investigated the three representative methods for the pipe deterioration assessment such as evaluation methods 1995 and 2002, and the state evaluation method through literature reviews. The ten assessment factors were selected by considering large-diameter pipe characteristics as well as common factors with high priority in the three methods. Also, the weighting of the factors was estimated by a regression equation from experiments and analysis on domestic large-diameter pipelines and expert survey data. It is expected that the new assessment model developed by analysing the existing three models is more reliable to assess the deterioration of large-diameter pipe networks.

Electrical/Mechanical Diagnosis of Local Deterioration in 600V Shielded Twist Pair Cable in a Nuclear Power Plant (원전용 600V 차폐 꼬임쌍선 케이블의 국부열화에 대한 전기적/기계적 진단)

  • Park, Myeongkoo;Kim, Kwangho;Lim, Chanwoo;Kim, TaeYoon;Kim, Hyunsu;Chai, Jangbom;Kim, Byungsung;Nah, Wansoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.203-210
    • /
    • 2017
  • In this paper, we propose a electrical/mechanical method to effectively diagnose the local deterioration of a 10m long power shielded twist pair cable defined by the American Wire Gauge (AWG) 14 specification using electrical/mechanical methods. The rapid deterioration of the cable proceeded by using the heating furnace, which is based on the Arrhenius equations proceeds from 0 to 35 years with the deteriorated equivalent model. In this paper, we introduce a method to diagnose the characteristics of locally deteriorated cable by using $S_{21}$ phase and frequency change rate measured by vector network analyzer which is the electrical diagnostic method. The measured $S_{21}$ phase and rate of change of frequency show a constant correlation with the number of years of locally deteriorated cable, thus it can be useful for diagnosing deteriorated cables. The change of modulus due to deterioration was measured by a modulus measuring device, which is defined by the ratio of deformation from the force externally applied to the cable, and the rate of modulus change also shows a constant correlation with the number of years of locally deteriorated cable. Finally, By combining the advantages of electrical/mechanical diagnostic methods, we can efficiently diagnose the local deterioration in the power shielded cable.

Experimental Study on Deterioration Characteristics under Combined Exposure Conditions of Chlorides and Sulfates (염화물 및 황산염 복합환경 하에서의 열화특성에 관한 실험적 연구)

  • 오병환;인광진;강의영;김지상;서정문
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.771-776
    • /
    • 2001
  • Test results on the deterioration process of concrete under single and combined attacks of chloride penetration have been obtained. After test period of 52 weeks, it is found that the internally penetrated chloride ion contents are less in the single attacks of chloride than the combined attacks of chloride and sulfate. Both the diffusion coefficients and surface chloride concentration derived form the chloride profiles showed a time dependence. Also the performance of fly ash-blended cements was observed to be better than plain cements in retarding chloride attack. However it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF