• 제목/요약/키워드: Deterioration Characteristics

검색결과 980건 처리시간 0.035초

자갈도상의 노후화에 따른 궤도구조의 동적거동에 관한 연구 (A study on the Dynamic Behaviors of Track due to Deterioration characteristics of Ballast)

  • 박용걸;최정열;강덕만
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.591-596
    • /
    • 2005
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several shcolars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

자갈도상의 노후화에 따른 궤도구조의 동적거동에 관한 연구(II) (A study on the Dynamic Behaviors of Track due to Deterioration characteristics of Ballast(II))

  • 서수은;박용걸;최정열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.854-859
    • /
    • 2005
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several shcolars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

현장측정을 통한 자갈도상궤도의 동적 거동 분석 (A Study on the Dynamic Behaviors of Ballast Track using Field Test)

  • 박용걸;최정열
    • 한국철도학회논문집
    • /
    • 제9권4호
    • /
    • pp.401-411
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

현장측정을 통한 자갈도상 궤도의 동적 거동 분석 (A Study on the Dynamic Behaviors of Ballast Track using Field Test)

  • 최정열;박균서;류중열;박정근;류경식;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.494-507
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

  • PDF

접지시스템에 사용되는 접속요소의 열화특성 분석 (Analysis of Deterioration Characteristics for Connection Factor used in Grounding System)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.9-13
    • /
    • 2015
  • This paper describes the analysis of deterioration characteristics for connection factor used in grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

고층고밀 아파트단지의 노후특성 평가 연구 - 1기 신도시 중 분당신도시의 아파트단지를 대상으로 - (Deterioration Characteristics through Evaluating the Level of Deterioration of High-rise and High-density Apartments)

  • 조성희;이태경;오덕성
    • 한국주거학회논문집
    • /
    • 제20권6호
    • /
    • pp.89-99
    • /
    • 2009
  • The purpose of this research is to determine the deterioration characteristics of high-rise and high-density apartment complexes in 1st period new towns in order to regenerate apartments as sustainable residential environments in Korea. For this purpose, the level of deterioration was evaluated by using 'evaluating indicators of the level of deterioration of high-rise and high-density apartments'. The deterioration characteristics were determined inclusively and concretely based on evaluation results. In addition, the deterioration level according to residents' awareness of the deterioration of their apartment was evaluated. This study was conducted by methods of field data collection, staff interview, field measurement, and resident survey according to the measurement of the evaluating indicators. And the re-organized questionnaire based on the evaluating indicators was utilized for a survey of resident's awareness. The results are as follows: In the physical dimensions of apartments, the deterioration characteristics included deteriorated equipment and a decline in structural performance due to the aging of the apartment, a shortage of parking spaces, and the low flexibility of the bearing wall structure, etc. In terms of the social dimensions, the apartments showed an increase in the number of elderly households, a shortage of community facilities, and a lack of the opportunity for community participation etc. In terms of the economic dimensions, the apartments showed limitations in maintenance & repair and a lack of environmentally friendly features.

SN으로 개질된 에폭시 수지 계의 흡습열화 특성 (Humidity Absorbing Deterioration Characteristics of Modified Epoxy Resin System with SN)

  • 조영신;심미자;박수길;김상욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 1996
  • Effects of humidity absorbing deterioration on AC dielectric breakdown characteristics of modified epoxy resin system with SN(succinonitrile) were investigated. As the forced humidity absorbing deterioration proceeded under high temperature and humidify, glass transition temperature increased. The dielectric breakdown strength increased and then decreased at deterioration cycles higher than 2. Not only, the increment of thermal stability but also, the physical detects such as Internal cracks and voids occurred during the humidity absorbing deterioration cycle were the main causes of the change in dielectric properties.

  • PDF

접지시스템의 접속방식에 따른 접속요소의 열화특성 분석 (Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System)

  • 길형준;김향곤;김동욱;김동우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

AC PDP 보호막 MgO의 단시간 열화시험방법에 관한 연구 (A Study on the Short-Term Deterioration Test Method of MgO in AC PDP)

  • 김윤기;허정은;김영기;이호준;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권12호
    • /
    • pp.578-583
    • /
    • 2002
  • For ac PDP, the lifetime should be guaranted over, 30000 hours. The lifetime is correlated with the deterioration characteristics for the weakest element in ac PDP. However, the short-term deterioration test method of the at PDP has not well developed. In this paper, a short term deterioration test method of a given element in the ac PDP is proposed. By this method, MgO deterioration characteristics are investigated. The deterioration rate is decreased with MgO thickness but it was almost saturated over 5000$\AA$.

뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성과 피뢰기 열화진단 전문가 시스템 (Electrical Characteristics of ZnO Blocks by a Lightning Impulse Current and the Expert System to Diagnose Arrester Deterioration)

  • 길경석;한주섭;송재용;김명진;김정배;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.152-157
    • /
    • 2002
  • This paper describes an effect of a single- and a quadruple-lightning impulse currents on electrical characteristics of ZnO blocks, and an expert system to diagnose arrestor deterioration. To deduce the parameters needed for diagnosing arrester deterioration, an accelerate deterioration teat is carried out. In the experiment, leakage current components are measured. Also, wave height distribution of the leakage current according to the progress of arrester deterioration is analyzed. From the experimental results, the wave height distribution of the leakage current showed conspicuous difference even in an immaterial leakage current increase. Therefore, the use of wave height distribution of the leakage current in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only a leakage currant value. Finally, the expert system based on the experimental results is developed and the system can diagnose arrestor deterioration by measuring the leakage current and its wade height distribution.