• Title/Summary/Keyword: Detector tube

Search Result 214, Processing Time 0.025 seconds

Urinary Trans, Trans-Muconic Acid is Not a Reliable Biomarker for Low-level Environmental and Occupational Benzene Exposures

  • Jalai, Amir;Ramezani, Zahra;Ebrahim, Karim
    • Safety and Health at Work
    • /
    • v.8 no.2
    • /
    • pp.220-225
    • /
    • 2017
  • Background: Benzene is a known occupational and environmental pollutant. Its urinary metabolite trans, trans-muconic acid (tt-MA) has been introduced by some environmental and occupational health regulatory associations as a biological index for the assessment of benzene exposure; however, recently, doubts have been raised about the specificity of tt-MA for low-level benzene exposures. In the present study, we investigated the association between urinary levels of tt-MA and inhalational exposure to benzene in different exposure groups. Methods: Benzene exposure was assessed by personal air sampling. Collected benzene on charcoal tube was extracted by carbon disulfide and determined by a gas chromatograph (gas chromatography with a flame ionization detector). Urinary tt-MA was extracted by a strong anion-exchange column and determined with high-performance liquid chromatography-UV. Results: Urinary levels of tt-MA in intensive benzene exposure groups (chemical workers and police officers) were significantly higher than other groups (urban and rural residents), but its levels in the last two groups with significant different exposure levels (mean = 0.081 ppm and 0.019 ppm, respectively) showed no significant difference (mean = $388{\mu}g/g$ creatinine and $282{\mu}g/g$, respectively; p < 0.05). Before work shift, urine samples of workers and police officers showed a high amount of tt-MA and its levels in rural residents' samples were not zero. Conclusion: Our results suggest that tt-MA may not be a reliable biomarker for monitoring low-level (below 0.5 ppm) benzene exposures.

인공 항문계를 이용한 대두박 isoflavones의 생체 이용성 평가

  • 김경진;지규만
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2000.11a
    • /
    • pp.91-93
    • /
    • 2000
  • Soybean meal(SMB) has not only been an important source of protein, but also a major source of isolfavones(IF) for poultry diet. Since the IF is one of effective phytoestrogens, evaluation of bioavailability of the phytochemicals for poultry and development of an animal model for assessment of the availability should be essential for its practical application. Present study was to develop bird model for assessing their bioavailability. No reports for such measurments with poultry could have every been found. Eight, 6-wk-old, layer-type, male birds were divided into two groups of four birds; normal (N) and colostomized(COL). Each bird was tube-fed a SMB sample at a level of 1% body weight. Samples from blood, urine and feces(COL birds) or urine+feces (N) were collected at 0, 2, 8, 15, 24 and 48 hours after the feeding. Plasma and urine samples were treated with -glucuronidase and fecal samples with 4N HCl for measurement of genistein(GE) and daidzein (DA) with HPLC set with an electrochemical detector. Maximum peaks of plasma IF appeared at 2 h after the meal for both birds groups. However the IF peak for N group was GE, while that for COL group was DA. Plasma DA levels for COL birds were always higher than those of GE, which was in opposite trend for N birds. This trend observed in the N birds is in accordance with those reported in rats fed SBM. In conclusion the results seem to suggest that colostomy as an attempt to separate urine from feces in birds affected the IF metabolism in the intestine and may not be a proper bird model to measure the IF bioavailability.

  • PDF

Development of Biologically Active Compounds from Edible Plant Sources-XI -Analysis of Phytol Content in Several Varieties of Lactuca sativa L. by gas chromatography- (식용식물자원으로부터 활성물질의 탐색-XI -GC를 이용한 상추(Lactuca sativa L.)의 품종별 Phytol 함량 분석-)

  • Song, Myoung-Chong;Lee, Jin-Hee;Bang, Myun-Ho;Kim, Ji-Young;Chung, Dae-Kyun;Pai, Tong-Kun;Kim, In-Ho;Baek, Nam-In
    • Applied Biological Chemistry
    • /
    • v.47 no.4
    • /
    • pp.426-429
    • /
    • 2004
  • An easy, sensitive and rapid method for the analysis of phytol, a strong ACAT (Acyl-CoA: Cholesterol Acyltransferase) inhibitory diterpenoid, was established. The pre-treatment of sample for GC analysis of phytol includes aq. MeOH extraction, partition of the extracts between EtOAc and water, and filtration of organic phase through Supelclean LC-Si SPE tube. The GC analysis of phytol for a variety of Lactuca sativa was carried out on DB-5 capillary column with flame ionization detector (FID). The consistency in phytol contents according to each variety was not shown. Especially, Jeoktoma, as RS-2 type, showed the highest phytol content.

Distribution of the Scatter Ray on Chest X-ray Examinations (흉부 X선 촬영 시 산란선 분포 연구)

  • Cho, Pyong-Kon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.7
    • /
    • pp.255-260
    • /
    • 2012
  • This study aims to examine the generation of scatter rays by dividing it into the presence of the subject at the chest X-ray examination, the X-ray tube and detector in the X-ray room, the front of the patient window, the outside of the entrance door of the patient waiting room, opening of the entrance door, the outside of the radiological technologist's entrance door, and the opening of the radiological technologist's entrance door, etc. When there is a subject, as the subject is thicker, more scatter rays occur at each of the spots for measurement. And when the entrance door is closed at the measurement, fewer scatter rays are generated.

Application of portable digital radiography for dental investigations of ancient Egyptian mummies during archaeological excavations: Evaluation and discussion of the advantages and limitations of different approaches and projections

  • Seiler, Roger;Eppenberger, Patrick;Ruhli, Frank
    • Imaging Science in Dentistry
    • /
    • v.48 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: In the age of X-ray computed tomography (CT) and digital volume tomography (DVT), with their outstanding post-processing capabilities, indications for planar radiography for the study of the dentition of ancient Egyptian mummies may easily be overlooked. In this article, the advantages and limitations of different approaches and projections are discussed for planar oral and maxillofacial radiography using portable digital X-ray equipment during archaeological excavations. Furthermore, recommendations are provided regarding projections and sample positioning in this context. Materials and Methods: A total of 55 specimens, including 19 skeletonized mandibles, 14 skeletonized skulls, 18 separate mummified heads, and 4 partially preserved mummies were imaged using portable digital X-ray equipment in the course of archaeological excavations led by the University of Basel in the Valley of the Kings between 2009 and 2012. Images were evaluated by 2 authors with regard to the visibility of diagnostically relevant dental structures using a 4-point grading system(Likert scale). Results: Overall, the visibility of diagnostically relevant dental structures was rated highest by both authors on X-ray images acquired using a dental detector. The tube-shift technique in the lateral projections of mandibular dentition achieved the second-best rating, and lateral projections achieved the third-best rating. Conclusion: Conventional planar digital X-ray imaging, due to its ubiquity, remains an excellent method-and often the only practicable one-for examining the skulls and teeth of ancient Egyptian mummies under field conditions. Radiographic images of excellent diagnostic quality can be obtained, if an appropriate methodology regarding the selected projections and sample placement is followed.

Developement of Radiation Measuring System using Wireless Communication (무선통신을 이용한 방사선측정 시스템 개발)

  • Lee, Bong-Jae;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.85-95
    • /
    • 1995
  • Radiation measuring system using wireless communication method with single channel has been diveloped and tested. In this system, radiation signals from GM tube are transformed into digital pulses in pulse processing circuit and modulated in FSK (frequency shift keying) circuit for digital communication and then wirelessly transmitted to a receiving unit. The digital pulses received are then demodulated in FSK circuit and converted into radiation dose/dose rate in the data acquisition unit to display on the screen of a personal computer. The performance of this system was evaluated by using both a pulse generator and a standard radiation source(Cs-137). In both cases, digital pulses with 5V were observed in pulse processing circuit without distortion of their shape through wireless communication system. The experimental results of radiation measurement by this system after several test-irradiation of GM detector to a standard radiation source(Cs-137), showed good agreement with irradiation dose rate within 10% difference, and proved that this system could be effectively utillized as radiation measuring instrument. It is expected that this wireless radiation measuring system developed for the first time in Korea, can be used as a radiation monitor as well as a personal dosimeter if we can further improve this system to adopt wireless multichannel communication system.

  • PDF

Development of a Coded-aperture Gamma Camera for Monitoring of Radioactive Materials (방사성 물질 감시를 위한 부호화 구경 감마카메라 개발)

  • Cho, Gye-Seong;Shin, Hyung-Joo;Chi, Yong-Ki;Yoon, Jeong-Hyoun
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.257-261
    • /
    • 2004
  • A coded-aperture gamma camera was developed to increase the sensitivity of a pin hole camera made with a pixellated CsI(Tl) scintillator and a position-sensitive photomultiplier tube. The modified round-hole uniformly redundant array of pixel size $13{\times}11$ was chosen as a coded mask considering the detector spatial resolution. The performance of the coded-aperture camera was compared with the pin hole camera using various forms of Tc-99m source to see the improvement of signal-to-noise ratio or the improvement of the sensitivity. The image quality is much improved despite of a slight degradation of the spatial resolution. Though the camera and the test were made for low energy case, but the concept of the coded-aperture gamma camera could be effectively used for the radioactive environmental monitoring and other applications.

Studies on the Simultaneous Determination of VNA and TSNA by GC - TEA (Gas chromatography-Thermal Energy Analyzer에 의한 휘발성 니트로소아민과 담배 특유의 니트로소아민들의 동시 분석연구)

  • Rhee, Mun-Su;Ji, Sang-Woon;Park, Yang-Su
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 1993
  • This is to investigate the methodology for the simultaneous determination of Wk, mk and TSNA using gas chromatography(GC) in combination with chemiluminescence detector, thermal energy analyzer(TEA) . The simultaneous analysis has been estimated by evaluating tobacco. The TEA was linked to GC equipped with non -polar SPB -5 fused silica capillary column which was introduced into the ceramic pyrolysis tube by the point of 16cm from the end of TEA. Quantification was carried out by internal standardization with WDPA after calibration of retention times and response factors with authentic nitrosoamines. It was demonstrated that WDPA was most preferable as internal standard for the simultaneous analysis. The recoveries of the internal standard were in the range of 83∼96% . Nitrosoamines in this method were detected with determination limit of 0.1ng and was made by a straight line in calibration curve by TEA response. The suitability of nitrosoamines extraction in tobacco leaf was investigated. It was most suitable to extract nitrosoamines from tobacco leaves with 0.01 M NaOH within a period of 8 hours. Thimerosal as an antibacterial agent was added to NaOH solution to prevent artifactual formation. The fractionation and the purification of nitrosoamines form alkaline extracts were conveniently performed using Extrelut multilayer column and dichloromethane. Reproducible and reliable results were obtained for the determination of nitrosamines in a relatively short time compared to previous known method. TSNA contents in burley were about 4 times higher as those in the fluecured tobacco.

  • PDF

The development of tube voltage meter using the semiconductor (반도체소자를 이용한 관전압계의 개발)

  • Seon, Jong-Ryul;Shin, Dae-Chul
    • Journal of radiological science and technology
    • /
    • v.25 no.2
    • /
    • pp.71-75
    • /
    • 2002
  • According to this study, we can make the radiation check meter which have not supply because of high cost and import barrier and lengthen its life by means of repairing of radiation bomb and equipment. We can make better medical service. In my study, I used the photodiod, photoelectron, among semiconductor detectors which have a excellent detect capacity and are low cost and small size. I set up this equipment in June 1, 2002, used 640 mA remote operative fluorography equipment, which make the grade as capacity test. I used the standard measuring instrument which took proofs from a agency, now it was using in measuring agency. The comparative measuring instrument used in same condition. I took the standard which was gauged with a connecting measuring instrument. Using a existing unconnected measuring instrument, I compared the accuracy with new unconnected one. As a result, three score are within the standard. For the detailed analysis, I took the average of percentage average error. So standard instrument was -0.02, comparable was -0.22, and new one was -0.17. New one took a closer measured value with standard than comparable one. In more study, I think to take more accurate value. I expect that my study will be a base of measuring instrument, with low cost, supply of this instrument increase, I expect to decrease radiation bomb and maintain, repair and manager better.

  • PDF

Components of phytoncide from a pine forest in the southern temperate zone

  • Lee, Jeong Do;Park, Choong Hee;Joung, Da Wou;Koo, Seung Mo;Park, Bum Jin
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • This study was conducted to examine the components of phytoncide from a pine forest in the southern temperate zone. Recent studies have found that a large amount of phytoncide is released not only from cypress trees but also from pine trees. Because the amount released is the highest during summer, we selected a warm climate region in the southern temperate zone and measured the concentration in the month of August. To capture the phytoncide from the forest atmosphere, we used the adsorption tube method with a mini pump and successfully gathered 9 L of forest air at a flow rate of 150 mL/min. We performed duplicate sampling from two different tubes installed at the same location and derived the mean value. A gas chromatography/mass spectrometer detector with thermal desorption spectroscopy was utilized to perform quantitative and qualitative analyses of the captured material. The results showed that the average phytoncide particle of the pine forest in the southern temperate zone contained a number of components as follows in descending order: ${\alpha}$-Pinene (39%, $0.28ng/m^3$), followed by ${\beta}$-Pinene (16%, $0.11ng/m^3$), D-Limonene (8%, $0.06ng/m^3$), camphor (6%, $0.04ng/m^3$), camphene (6%, $0.04ng/m^3$), and p-Cymene (5%, $0.04ng/m^3$). There were also 13 additional phytoncide components in trace amounts. The results of this study are expected to provide a useful dataset for building a "Healing-forest".