• 제목/요약/키워드: Detector materials

검색결과 503건 처리시간 0.024초

3C-SiC 마이크로 히터의 제작과 그 특성 (Fabrication of 3C-SiC micro heaters and its characteristics)

  • 정귀상;정재민
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.311-315
    • /
    • 2009
  • This paper describes the characteristics of a poly 3C-SiC micro heater which was fabricated on AlN(0.1 $\mu$m)/3C-SiC(1.0 $\mu$m) suspended membranes by surface micro-machining technology. The 3C-SiC and AlN thin films which have wide energy band gap and very low lattice mismatch were used sensors for high temperature and voltage environments. The 3C-SiC thin film was used as micro heaters and temperature sensor materials simultaneously. The implemented 3CSiC RTD(resistance of temperature detector) and the power consumption of micro heaters were measured and calculated. The TCR(thermal coefficient of the resistance) of 3C-SiC RTD is about -5200 ppm/$^{\circ}C$ within a temperature range from 25 $^{\circ}C$ to 50 $^{\circ}C$ and -1040 ppm/$^{\circ}C$ at 500 $^{\circ}C$. The micro heater generates the heat about 500 $^{\circ}C$ at 10.3 mW. Moreover, durability of 3C-SiC micro heaters in high voltages is better than Pt micro heaters. A thermal distribution measured and simulated by IR thermovision and COMSOL is uniform on the membrane surface.

식용란의 플루오로퀴놀론계 합성항균제의 잔류에 관한 조사 (Surveys on the residual level of fluoroquinolones in eggs)

  • 고바라다;박성도;장미선;나호명;김용환
    • 한국동물위생학회지
    • /
    • 제28권3호
    • /
    • pp.235-243
    • /
    • 2005
  • This surveies were carried out to investigate the residual levels of fluoroquinolones in chicken and quail eggs by bioassay and HPLC method. The eggs of 240 samples collected from market and farm in Gwangju Metropolitan city were examined from May to December in 2003. Residual antibiotic materials were detected from 47 samples of the 240 eggs by bioassay. Of the 240 eggs assayed, ciprofloxacin, danofloxacin, norfloxacin, ofloxacin, orbifloxacin and perfloxacin were not detected but enrofloxacin was detected from 5 samples in 228 chicken eggs and 1 sample in 12 quail eggs using HPLC with fluorescence detector by multi-residue method. 2 sample eggs in 6 sample which were detected by HPLC were not positive with bioassay. The average residual concentration of enrofloxacin was 0.494 mg/kg in 6 positive samples. The highest residual concentration of enrofloxacin was 1.83mg/kg.

국내 시판 중인 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 탈착 및 저장성 평가 연구 (Research on desorption and stability of benzene, toluene, acetone and n-hexane of activated carbon acquired from domestic market)

  • 이나루;이광용
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.353-358
    • /
    • 2014
  • Purpose: This study was conducted to evaluate desorption efficiency and storage stability on activated carbon acquired form domestic market. Materials: Mixture of acetone, benzene, normal hexane and toluene was injected on four types of charcoal 100 mg. After overnight, charcoal was desorbed by carbon disulfide $1m{\ell}$ and analyzed by gas chromatography with flame ionization detector. Results: Desorption efficiency of benzene, normal hexane and toluene in charcoal tubes were 95% ~ 105%. But desorption efficiency of acetone in charcoal tubes was below 75% and different from types of charcoal. The more injected amount of acetone on charcoal showed higher desorption efficiency. Acetone injected on charcoal tubes migrated from front section into back section after 10 days storage at room temperature. Conclusions: Desorption efficiency and storage stability of activated carbon acquired from domestic market was good for benzene, normal hexane and toluene. The activated carbon acquired from domestic market has ability to be used as sampling media.

Elemental analysis by neutron induced nuclear reaction - Nuclear track method for the analysis of fissile materials

  • Ha, Yeong-Keong;Pyo, Hyung Yeol;Park, Yong Joon;Jee, Kwang Yong;Kim, Won Ho
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.263-270
    • /
    • 2005
  • 핵분열트랙은 우라늄, 플루토늄, 토륨 등의 방사성핵종 분석이나, 리튬이나 붕소와 같이 열중성자와 핵반응을 하는 원소분석에 매우 유용하다. 이 방법은 대기 중의 방사성핵종 분석을 통해 핵무기 실험을 검출한다거나, 우주공간의 중이온에 대한 선량측정이나 운석의 우주선 조사과정 추정, 원자력분야의 핵분열률 측정, 암석의 연대 및 역사를 파악하거나, tracer로 사용하는 등 여러 분야에 적용 가능하다. 현재 원자력연구소에서는 알파트랙기입법을 이용한 미량의 보론 분석이나, 핵분열트랙을 이용한 우라늄 등의 핵물질을 포함한 입자분석에 적용하고 있다. 본 총설에서는 트랙형성의 이론적 배경, 에칭된 트랙을 얻는 실제 과정 및 앞으로의 전망 등에 대해 살펴보았다.

파노라마방사선사진과 다면상재구성 CT상의 치조골 높이 계측에 대한 비교 연구 (Comparative study on alveolar bone height of pantomography and multi planar reformatted computed tomography)

  • 지정현;이상래;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권3호
    • /
    • pp.159-164
    • /
    • 2004
  • Purpose: To compare alveolar bony height of pantomograph with bony height of thin slice, multiplanar reformatted (MPR) Computed Tomograph. Materials and Methods : Panoramic radiograms of 12 young adult patients had been taken by one radologic technitian and the measurements were corrected by magnification ratio (1.20). The slice thickness of Multi-detector Computed Tomography (CT) was at least 1mm for the accuracy. The raw CT datas were imported into the V-works 4.0 (CyberMed Corp., Seoul, Korea) and transformed to MPR images. Pantomographic measurements of alveolar bone were compared to CT values by average mean bony height measurements for the accuracy. Inter-, and Intra-observer variability was evaluated. Results : There was no significant differences between height measurement of pantomography and that of CT (P>0.05). There were no significant differences in either inter-or intra-observer measurements (P>0.05). Conclusion : Pantomography showed relatively high accuracy and precision in measuring alveolar bony height.

  • PDF

컨베이어벨트의 비접촉식 스틸코드파선 검사장치 개발 (Development of Non-contact Detector for Broken Cords of Steel-Cord Conveyor Belt)

  • 유재상;손봉호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2535-2537
    • /
    • 2000
  • In order to detect and monitor the broken cords of steel-cord belt from being damaged by impact of large lump of materials and the corrosion of steel cord, we developed a non-contact magnetic coil detection system. This measures the deterioration of reinforcing cables in steel cord conveyor belt which transport the ores in raw material plant. In this research, magnetic coil sensor of broken-cord detection system has exciting part and sensing part. The broken-cord detection system is operated by supplying a transmitter coil with electric power to generate magnetic field, and then the change of induced voltage is detected in each receiver coils due to resultant magnetic flux effected by the broken steel cords at the inside of the conveyor belt. By the informations such as the position and size of the broken steel cords obtained by SCBMS(Steel Cord Belt Monitoring System), it is expected that not only the span of belt life will be lengthened, but also this system can enable operators to plan scheduled maintenance and prevent the enlargement of damaged parts in steel cord belt at an early stage

  • PDF

전력설비의 열화 진단을 위한 연면방전 모델에서의 코로나 방전 특성 분석 (The Analysis of Corona Discharge of Surface Flashover Model for Aging Diagnosis of Power Facility)

  • 방만식;최재형;김우진;김영석;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.314-318
    • /
    • 2011
  • Recently, ultrasound, infrared detector, V-I characteristic, gas analysis, UV (ultra-violet rays) camera etc. is used as inspections and diagnoses of the safety of power equipment. Especially, UV camera have attracted a great deal of interest from the view point of easy judgement. UV camera is used corona discharge. One of the most important and difficult problems to be solved filer design, materials and corona discharge. This paper is studied on the temperature characteristics, UV generation and shape analysis and corona pulse count according to the electrode distance and applied voltage. Also, Corona discharge characteristics in air are analyzed using prototype UV camera of Korea. UV generation due to surface discharge of AC is higher than that of DC.

위상고정 Loop를 사용한 안정 징파발진기 (Microwave Oscillator Stabilized by Phase-locked Loop)

  • 나정웅;김종진
    • 대한전자공학회논문지
    • /
    • 제12권3호
    • /
    • pp.20-25
    • /
    • 1975
  • 추상고정 loop (PLL)를 사용하여 안정화시킨 징파 발진기를 개발하였다. 체내제작이라는 관점에서 특수 기봉가공을 한 특수자재 cavity를 사용한 자파수 안정화보다 PLL방법을 채택하였다. 입력 주파수가 다른 두 신호과 위상을 직접 비교할 수 있는 위상검파기로서 sampler와 저주파 filter를 사용할 수 있음을 보였으며, 이 목적에 맞는 약 4 GHz 대까지 sample 할 수 있는 sampler를 개발하였다. 2.16 GHz 대에서 출력이 120mW 이상인 징파발진기를 VCO로 사용하고, 110MHz대에서 발진하는 수품판 발진기를 기준발진기로서 사용한 PLL system으로 약 10-6 정도의 주파수 안정도를 얻을 수 있었다. 발진기 system의 capturing range는 search oscillator를 사용함으로써 lock-in-range인 10MHz대를 얻을 수 있었다.

  • PDF

중성자 비적 검출기 CR-39의 에너지 및 입사각 응답특성 (Energy and Angular Response of CR-39 Neutron Track Detector)

  • Kim, Jang-Lyul;Ha, Chung-Woo;Yoon, Yea-Chang;W.G. Cross;A. Arneja
    • Nuclear Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.71-79
    • /
    • 1988
  • 중성자 에너지의 함수로써 여러 연구기관들에 의하여 발표된 CR-39검출기의 효율측정은 서로 많은 차이가 있음을 보여주고 있다. 이러한 차이는 부식조건, 방사체의 물질과 두께, 각 회사 제품에 따른 CR-39의 감도 그리고 계수하는 부식직경의 크기 등에 기인된다. 본 논문에서는 계산결과와 함께 에너지 및 각에 따른 분포에 대한 효과들을 검토하였다. 몇가지 에너지에 대해서만 수행된 중성자 입사각에 따른 반응변화의 계산 및 실험결과는 에너지 반응의 결과보다 더욱 일치하는 것을 알 수 있었다. 계산결과에 따르면 입사각에 대한 반응은 약 0.3 MeV 이하를 제외하고는 중성자 에너지에 다라 심하게 변하지 않는다는 것을 보여준다.

  • PDF

다결정 3C-SiC 멤브레인 위에 균일한 온도분포를 갖는 마이크로 히터의 제작과 그 특성 (Fabrication of micro heaters with uniform-temperature area on poly 3C-SiC membrane and its characteristics)

  • 정귀상;정재민
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.349-352
    • /
    • 2009
  • This paper describes the fabrication and characteristics of micro heaters built on AlN($0.1{\mu}m$)/3C-SiC($1{\mu}m$) suspended membranes by surface micromachining technology. In this work, 3C-SiC and AlN films are used for high temperature environments. Pt thin film was used as micro heaters and temperature sensor materials. The resistance of temperature sensor and the power consumption of micro heaters were measured and calculated. The heater is designed for operating temperature up to about $800^{\circ}C$ and can be operated at about $500^{\circ}C$ with a power of 312 mW. The thermal coefficient of the resistance(TCR) of fabricated Pt resistance of temperature detector(RTD)'s is 3174.64 ppm/$^{\circ}C$. A thermal distribution measured by IR thermovision is uniform on the membrane surface.