• Title/Summary/Keyword: Detector

Search Result 6,182, Processing Time 0.033 seconds

A 145 GHz Imaging Detector Based on 65-nm RFCMOS Technology (65-nm RFCMOS공정 기반 145 GHz 이미징 검출기)

  • Yoon, Daekeun;Kim, Namhyung;Kim, Dong-Hyun;Rieh, Jae-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1027-1033
    • /
    • 2013
  • In this work, a D-band imaging detector has been developed in a 65-nm CMOS technology for high frequency imaging application. The circuit was designed based on the resistive self-mixing of MOSFET devices. The fabricated detector exhibits a maximum responsivity of 400 V/W and minimum NEP of 100 $pW/Hz^{1/2}$ at 145 GHz. The chip size is $400{\mu}m{\times}450{\mu}m$ including the probing pads and a balun, while the core of the circuit occupies only $150{\mu}m{\times}100{\mu}m$.

A Time-Varying Modified MMSE Detector for Multirate CDMA Signals in Fast Rayleigh Fading Channels

  • Jeong, Kil-Soo;Yokoyama, Mitsuo;Uehara, Hideyuki
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.143-152
    • /
    • 2007
  • In this paper, we propose a time-varying modified minimum mean-squared error (MMSE) detector for the detection of higher data rate signals in a multirate asynchronous code-division multiple-access (CDMA) system which is signaled in a fast Rayleigh fading channel. The interference viewed by a higher data rate symbol will be periodic due to the presence of a lower data rate symbol which spans multiple higher data rate symbols. The detection is carried out on the basis of a modified MMSE criterion which incorporates differential detection and the ratio of channel coefficients in two consecutive observation intervals inherently compensating the fast variation of the channel due to fading. The numerical results obtained by the MMSE detector with time-varying detection show around 3 dB (M=2) and 6 dB (M=4) performance improvement at a BER of $10^{-3}$ in the AWGN channel, while introducing more computational complexity than the MMSE detector without time-varying detection. At a higher $E_b/N_0$, the proposed scheme can achieve a BER of approximately $10^{-3}$ in the presence of fast channel variation which is an improvement over other schemes.

  • PDF

Robust End Point Detection for Robot Speech Recognition Using Double Talk Detection (음성인식 로봇을 위한 동시통화검출 기반의 강인한 음성 끝점 검출)

  • Moon, Sung-Kyu;Park, Jin-Soo;Ko, Han-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.161-169
    • /
    • 2012
  • This paper presents a robust speech end-point detector using double talk detection in echoic conditioned speech recognition robot. The proposed method consists of combining conventional end-point detector result and double talk detector result. We have tested the proposed method in isolated word recognition system under echoic conditioned environment. As a result, the proposed algorithm shows superior performance of 30 % to the available techniques in the points of speech recognition rates.

The dark-current and X -ray sensitivity measurement of hybrid digital X-ray detector having dielectric layer structure (a-Se 기반의 혼합형 X-선 검출기에서 유전층의 누설전류 저감효과)

  • Seok, Dae-Woo;Park, Ji-Koon;Joh, Jin-Wook;Lee, Dong-Gil;Moon, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.31-34
    • /
    • 2002
  • In this paper, the electric properties of amophous selenium multilayer samples has been investigated. In order to develop the hybrid flat-panel digital· X-ray image detector, we measured and analyzed their performance parameters such as the X -ray sensitivity and dark-current for a amophous selenium multilayers X-ray detector with a phosphor layer, The hybrid digital X-ray image detector can be constructed by integrating a phosphor layer (or a scintillative layer) that convert X-ray to a light on a-Se photoconduction mulilayers that convert a light to electrical signal. As results, the dielectric materials such as parylene between the phosphor layer and the top electrode may reduce the dark-current of the samples. Amorphous selenium multilayers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the hybrid X-ray detector.

  • PDF

Efficient LDPC-Based, Threaded Layered Space-Time-Frequency System with Iterative Receiver

  • Hu, Junfeng;Zhang, Hailin;Yang, Yuan
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.807-817
    • /
    • 2008
  • We present a low-density parity-check (LDPC)-based, threaded layered space-time-frequency system with emphasis on the iterative receiver design. First, the unbiased minimum mean-squared-error iterative-tree-search (U-MMSE-ITS) detector, which is known to be one of the most efficient multi-input multi-output (MIMO) detectors available, is improved by augmentation of the partial-length paths and by the addition of one-bit complement sequences. Compared with the U-MMSE-ITS detector, the improved detector provides better detection performance with lower complexity. Furthermore, the improved detector is robust to arbitrary MIMO channels and to any antenna configurations. Second, based on the structure of the iterative receiver, we present a low-complexity belief-propagation (BP) decoding algorithm for LDPC-codes. This BP decoder not only has low computing complexity but also converges very fast (5 iterations is sufficient). With the efficient receiver employing the improved detector and the low-complexity BP decoder, the proposed system is a promising solution to high-data-rate transmission over selective-fading channels.

  • PDF

A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography (전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구)

  • Im Y.B.;Moon H.M.;Joe H.T.;Paek Y.J.;Lee C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1741-1744
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

  • PDF

In-line Smart Oil Sensor for Machine Condition Monitoring (기계 상태진단을 위한 인-라인형 오일 모니터링 스마트 센서)

  • Kong, H.;Ossia, C.V.;Han, H.G.;Markova, L.
    • Tribology and Lubricants
    • /
    • v.24 no.3
    • /
    • pp.111-121
    • /
    • 2008
  • An integrated in-line oil monitoring detector assigned for continuous in situ monitoring multiple parameters of oil performance for predicting economically optimal oil change intervals and equipment condition control is presented in this study. The detector estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical intensity of oil in three optical wavebands ("Red", "Green" and "Blue") and water content is evaluated as Relative Saturation of oil by water. The detector is able to monitor oils with low light absorption (hydraulic, transformer, turbine, compressor and etc. oils) as well as oils with rather high light absorption in visible waveband (diesel and etc. oils). In a case study that the detector is applied to a diesel engine oil, it is found that the detector provides good results on oil chemical degradation as well as soot concentration.

A Mutual Exclusion Algorithm in Asynchronous Distributed System with Failure Detectors (비동기적 분산시스템에서 고장 추적 장치를 이용한 상호배제 알고리즘 설계)

  • Park, Sung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2457-2464
    • /
    • 2013
  • In this paper, we design and analyze a mutual exclusion algorithm, based on the Token and Failure detector, in asynchronous distributed systems. A Failure Detector is an independent module that detects and reports crashes of other processes. There are some of advantages in rewriting the Token-based ME algorithm using a Failure Detector. We show that the Token-based ME algorithm, when using Failure Detector, is more effectively implemented than the classic Token-based ME algorithm for synchronous distributed systems.

An Exponential Smoothing Adaptive Failure Detector in the Dual Model of Heartbeat and Interaction

  • Yang, Zhiyong;Li, Chunlin;Liu, Yanpei;Liu, Yunchang;Xu, Lijun
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • In this paper, we propose a new implementation of a failure detector. The implementation uses a dual model of heartbeat and interaction. First, the heartbeat model is adopted to shorten the detection time, if the detection process does not receive the heartbeat message in the expected time. The interaction model is then used to check the process further. The expected time is calculated using the exponential smoothing method. Exponential smoothing can be used to estimate the next arrival time not only in the random data, but also in the data of linear trends. It is proven that the new detector in the paper can eventually be a perfect detector.

Development of a Bipolar Pulse Conductometric Detector for Environmental Monitoring and Electrochemical Experiments (환경수질오염 검증과 전기화학실험을 위한 양극펄스형 전기전도성검출기의 개발)

  • Kim, Haidong;Kim, Sun Tae;Kim, Taek-Jae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.79-82
    • /
    • 1992
  • A bipolar pulse conductometric detector has been developed for continuous on-line monitroring of the flowing sample streams. The conductometric detector was fast and easy to use due to the free of interferences by serial or parallel capacitances. The performance of the bipolar pulse conductometric detector was tested using dummy cells with $10^1{\sim}10^8$ ohm resistance range and found a linear response with a 0.01% relative standard deviation. The possible applications of the bipolar pulse conductometric detector was discussed.

  • PDF