• 제목/요약/키워드: Detector

검색결과 6,218건 처리시간 0.032초

낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구 (Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray)

  • 이순혁;정재훈;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.95-99
    • /
    • 2014
  • 병원을 포함해서서 방사선 물질을 사용하는 모든 사업장에서 방사선 물질의 모니터링은 방사선 안전에 가장 중요한 요소의 하나이다. 본 연구는 방사선 모니터링 시스템에 있어서 GEM 검출기의 활용 가능성을 알아보기 위한 선행 연구로서, GEM 검출기를 제작하고 CdTe 검출기와의 상대적 효율을 구한 결과, 베타와 감마선에 대한 평균 상대 효율이 각각 72%와 4%로서 매우 우수한 성능을 나타냄을 보였다.

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • 대한화장품학회지
    • /
    • 제23권3호
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF

직접검출방식(直接檢出方式)에 의한 X선영상(X線影像)의 재구성(再構成)에 관(關)한 연구(硏究) (A K-Ray Image Reconstruction by the Direct Detection Method)

  • 강희두
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권1호
    • /
    • pp.61-72
    • /
    • 1991
  • In this paper, the rotating plate method extracting signal and reconstructing original image was proposed. The rotating methode has cell detector array each of which has used in the medical diagnosis X-ray photography. The major problem using the simple horizontal moving or non-moving methode is the size and number of detector cells which have the considerable affection on the sharpness and resolution of the reconstructed image. Secondary, the estimated pixel values of non-detected real points which are placed between detector cells will be the distorted pixels in the reconstructed image. Therefore, the proposed rotating plate method has the exact distribution on the uncertain pixels which were reconstructed by conventional methods to solve there problems. And then, the image using the rotated plate's cell out put signal was reconstructed on the computer simulation. The method will rotated the detector array plate to solve the reconstruction from the detector size and number of conventional methods. The result of simulation has estimated the original pixel position and 81 pixel/mm resolution which the reconsiderlation of the detector's moving orientation, the proposed method has 25 pixel/mm resolution. These results have been represented by 3-D computer graphics.

  • PDF

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

RF Power Detector for Location Sensing

  • Kim, Myung-Sik;Kubo, Takashi;Chong, Nak-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1771-1774
    • /
    • 2005
  • Recently, RFID has become popular in the field of remote sensing applications. Location awareness is one of the most important keys to deploying RFID for advanced object tracking. Generally, multiple reference RF stations or additional sensors are used for the location sensing with RFID, but, particularly in indoor environments, spatial layout and cost problems limit the applicability of those approaches. In this paper, we propose a novel method for location sensing with active RFID systems not requiring the need for reference stations or additional sensors. The system triangulates the position of RF signal source using the signal pattern of the loop antenna connected to the power detector. The power detector consists of a signal strength detector and a signal analysis unit. The signal analysis unit indicates the signal strength and serial number using the signal from the strength detector, and provides the direction of the signal to the application target. We designed three different signal analysis units depending on the threshold type. The developed system can sense the direction to the transponder located over 10 m away within the maximum error of $5^{\circ}$. It falls within a reasonable range in our normal office environment.

  • PDF

Optimization of airborne alpha beta detection system modeling using MCNP simulation

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.841-845
    • /
    • 2020
  • An airborne alpha beta detection system using passivated implanted planar silicon (PIPS) detector was modeled with the MCNP6 code and its resolution and detection efficiency were analyzed. Simulation of the resolution performed using the Gaussian energy broadening (GEB) function showed that the full width at half maximum (FWHM) of 35.214 keV for alpha particles was within 34-38 KeV, which is the FWHM range of the actual detector, and the FWHM of 15.1 keV for beta particles was constructed with a similar model to 17 keV, which is the FWHM range of an actual detector. In addition, the detection efficiency and the resolution were simulated according to the distance between the detector and the air filter. When the distance was decreased to 0.2 cm from 0.8 cm, the efficiency of the alpha and beta particles detection decreased from 5.33% to 4.89% and from 5.64% to 4.27%, respectively, and the FWHM of the alpha and beta particles improved from 40.9 KeV to 29.84 keV and 25.76 keV-13.27 keV, respectively.

그림자에 강건한 색상 기반 내잡음성 코너 검출자 (Hue-based Noise-tolerant Corner Detector Robust to Shadows)

  • 박기현;박은진;최흥문
    • 대한전자공학회논문지SP
    • /
    • 제41권6호
    • /
    • pp.239-245
    • /
    • 2004
  • 본 논문에서는 그림자가 존재하는 환경 하에서도 실제 코너만을 정확하게 추출할 수 있는 색상 기반 내잡음성 코너 검출자를 제안하였다. 먼저 그림자 경계에서 명도의 변화는 크지만 색상의 변화는 크지 않으므로 각 화소에 대한 HSI 색 공간에서 색상 가중 조합 벡터 기울기를 코너 검출자에 반영함으로써 그림자의 영향을 제거하고, 선택된 에지 화소 쌍의 색 변화 방향이 서로 반대 극성일 때는 코너 기여 가중치를 상쇄시킴으로써 불규칙 잡음에도 강건하게 코너를 검출하도록 하였다. 실험을 통하여 제안한 코너 검출자가 그림자 및 불규칙 잡음에도 강건하게 실제 코너만을 효과적으로 검출함을 확인하였다.

비냉각 열상시스템에서의 적외선 검출기의 열전소자(TEC) 부재에 대한 효율적인 제어기법 (Novel control scheme for the absence of the thermoelectric(TEC) of infrared detector in an Uncooled thermal system)

  • 김용진;서재길;김영길
    • 한국정보통신학회논문지
    • /
    • 제16권10호
    • /
    • pp.2335-2340
    • /
    • 2012
  • 비냉각 방식의 검출기는 검출기 내부에 냉각기 기능을 하는 열전소자(TEC : Thermal Electric Cooler)를 탑재하여 냉각기의 기능을 대신하고 있다. 이 열전소자의 기능은 검출기의 기준온도를 제어하여 온도변화에 따른 영상화질의 저하를 방지하는 역할을 수행한다. 최근에는 이 열전소자를 삭제하여 크기, 가격을 줄일 수 있는 노력이 많이 연구되고 있다. 본 논문에서는 비냉각 형태의 적외선 검출기는 내부에 열전소자가 없는 검출기를 보다 효과적으로 제어하여 영상의 화질저하를 최소화 하면서 크기를 최소화 하고 가격경쟁력을 높일 수 있는 효율적인 제어기법에 대해 실제 챔버를 활용한 시험결과를 제시하고자 한다.

약의존성 잡음에서 두 표본을 쓰는 국소 최적 확률 신호 검파기의 검정 통계량 (The Test Statistic of the Two Sample Locally Optimum Rank Detector for Random Signals in Weakly Dependent Noise Models)

  • 배진수
    • 한국통신학회논문지
    • /
    • 제35권8C호
    • /
    • pp.709-712
    • /
    • 2010
  • 이 논문에서는 시간상 확률 상관이 0이 아닌 약의존성 잡음 모형에서 두 표본을 쓰는 국소 최적 순위 검파기의 검정 통계량를 얻었다. 기준 관측과 보통 관측으로 이루어진 두 표본 관측 모형에서 약의존성 잡음 환경에 알맞은 국소 최적 순위 검파기의 검정 통계량을 네이먼 피어슨 정리로부터 유도하였다. 두 표본을 쓰는 국소 최적 순위 검파기는 한 표본을 쓰는 국소 최적 순위 검파기와 같은 점근 성능을 가지며 부호 통계량을 다룰 필요가 없어 얼개가 비교적 간단하다.

DS-CDMA 시스템을 위한 혼합 LMSF 블라인드 다중 사용자 검출 (Mixed LMSF Blind Multiuser Detector for DS-CDMA Systems)

  • 박성욱;박종욱
    • 전자공학회논문지 IE
    • /
    • 제43권2호
    • /
    • pp.75-79
    • /
    • 2006
  • 블라인드 기법은 훈련열 없이 검출하고자 하는 사용자의 최소한의 정보만을 가지고 정보 검출이 가능한 방법이다. 본 논문에서는 직접 대역 확산 코드 분할 다중 접속 시스템에서 다중사용자 간섭을 제거하기 위해서, 혼합된 비용함수를 사용하는 블라인드 다중사용자 검출기를 제안하였다. 제안된 블라인드 다중사용자 검출기의 비용함수는 LMS와 LMF를 혼합한 형태로 이루어져있으며, 제안된 다중사용자 검출기의 성능을 평가하기 위해서 가우시안 채널 하에서 BER을 비교 하였다. 모의실험 결과, 사용자가 20 명 존재하는 경우, 제안된 블라인드 검출기가 블라인드 MOE 다중사용자 검출기에 비해 약 3dB정도 더 나은 성능을 지님을 확인 할 수 있었다.