• 제목/요약/키워드: Detector

검색결과 6,182건 처리시간 0.035초

A New Formula to Predict the Exact Detection Probability of a Generalized Order Statistics CFAR Detector for a Correlated Rayleigh Target

  • Kim, Chang-Joo
    • ETRI Journal
    • /
    • 제16권2호
    • /
    • pp.15-25
    • /
    • 1994
  • In this paper we present a new formula which can predict the exact detection probability of a generalized order statistics (GOS) constant false alarm rate (DFAR) detector for a partially correlated Rayleigh target model (0 < $ \rho$< 1) in a closed form, where $\rho$ is the correlation coefficient between returned pulses. By simply substituting a set of specific coefficient into the derived formula, one can obtain the detection probability of any kind of CFAR detector. Detectors may include the order statistics CFAR detector, the censored mean level detector, and the trimmed mean CFAR detector, but are not necessarily restricted to them. The numerical result for the first order Markov correlation model as applied to some of the detectors shows that as $\rho$ increases from zero to one, higher signal-to-noise ratio is required to achieve the same detection probability.

  • PDF

열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발 (Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System)

  • 김민성;윤석호;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

신호 의존성 잡음에서 확률 신호 검파를 위한 비모수 방법 : 두 표본을 쓰는 경우 (A Nonparametric Method for Random Signal Detection in Signal-Dependent Noise : Two-Sample Case)

  • 김창배;송익호;배진수
    • 한국통신학회논문지
    • /
    • 제28권4C호
    • /
    • pp.374-378
    • /
    • 2003
  • 이 논문에서는 신호의존성 잡음과 가산성 잡음이 함께 있을 때 확률 신호를 찾아내는 두 표본을 쓰는 국소 최적 순위 검파기의 점근 성능을 다룬다. 비모수 검파기인 국소 최적 순위 검파기는 국소 최적 검파기와 비교하여 볼 때, 시간상으로 상관이 있는 확률 신호에 대해서 거의 같은 점근 성능을 가진다. 두 표본을 쓰는 국소 최적 순위 검파기는 한 표본을 쓰는 국소 최적 순위 검파기와 같게 수행한다는 점은 주목할 만하다.

An Optical Cavity Design for an Infrared Gas Detector Using an Off-axis Parabolic Mirror

  • Jeong, You-Jin;Kang, Dong-Hwa;Seo, Jae-Yeong;Jo, Ye-Ji;Seo, Jin-Hee;Choi, Hwan-Young;Jung, Mee-Suk
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.374-381
    • /
    • 2019
  • This study examined a method for designing the optical cavity of a non-dispersive infrared gas detector. The infrared gas detector requires an optical cavity design to lengthen the ray path. However, the optical cavity with multiple reflecting surfaces has off-axis aberration due to the characteristics of the reflecting optical system. The rays were parallelized by using the off-axis parabolic mirror to easily increase the ray path and eliminate off-axis aberration so that the rays are admitted to the effective area of the infrared detector uniformly. A prototype of an infrared gas detector was produced with the designed optical cavity to confirm the performance.

Growth and characterization of detector-grade CdMnTeSe

  • J. Byun ;J. Seo;J. Seo ;B. Park
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4215-4219
    • /
    • 2022
  • The Cd0.95Mn0.05Te0.98Se0.02 (CMTS) ingot was grown by the vertical Bridgman technique at low pressure. All wafers showed high resistivity, which suggests potential as a room-temperature semiconductor detector. The resistivity of the CMTS planar detector was 1.47 × 1010 Ω·cm and mobility lifetime product of electrons was 1.29 × 10-3 cm2/V. The spectroscopic property with Am-241 and Co-57 was evaluated. The energy resolution about 59.5 keV gamma-ray of Am-241 was 11% and the photo-peak of 122 keV gamma-ray from Co-57 was clearly distinguished. The result shows the first detector-grade CMTS in the world and proves CMTS's potential as a radiation detector operating at room temperature.

비정질 셀레늄 기반 디지털 방사선 검출기의 성능 평가 (Performance Evaluation of a Selenium(a-Se) Based Prototype Digital Radiation Detector)

  • 박지군;강상식;조성호;신정욱;김소영;손대응;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.300-305
    • /
    • 2007
  • In this study, we have studied the fabrication and the performance evaluation of digital radiation detector of the based on selenium (a-Se) prototype which is widely researched about recently. The detector was fabricated using amorphous selenium in the specification of active area size $7{\times}8.5"$, pixel pitch $139{\mu}m$, and 12 bit ADC. In order for the performance evaluation of the fabricated detector, we used radiation quality RQA 5 that is suggested by the International Electrotechnical Commission (IEC), and evaluated modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). Concerning MTF measurement, we used slit camera (Nuclear Associates, Model : 07-624-2222), and evaluated in the slit method. Also so as to compare the performance evaluation on the detector fabricated in this study, we used Hologic Direct-Ray (DR-1000) and GE Revolution XQ/I system, and evaluated and compared in the same method MTF, NPS, and DQE which are image quality factors. And as a result, the MTF of each detector In Nyquist frequency were evaluated to be 58% (at 3.5 lp/mm) in the case of DR-1000 and 65% (at 2.5 lp/mm) in the case of XQ/I, and that for the detector fabricated in this study was evaluated to be 36% (at 3.51 lp/mm). Also in the case of DQE(0), the detector fabricated in this study, DR-1000 of Hologic company, and XQ/I system of GE company respectively were evaluated as 36%, 32%, and 50%.

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권3호
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

컨볼루셔널 신경망과 케스케이드 안면 특징점 검출기를 이용한 얼굴의 특징점 분류 (Facial Point Classifier using Convolution Neural Network and Cascade Facial Point Detector)

  • 유제훈;고광은;심귀보
    • 제어로봇시스템학회논문지
    • /
    • 제22권3호
    • /
    • pp.241-246
    • /
    • 2016
  • Nowadays many people have an interest in facial expression and the behavior of people. These are human-robot interaction (HRI) researchers utilize digital image processing, pattern recognition and machine learning for their studies. Facial feature point detector algorithms are very important for face recognition, gaze tracking, expression, and emotion recognition. In this paper, a cascade facial feature point detector is used for finding facial feature points such as the eyes, nose and mouth. However, the detector has difficulty extracting the feature points from several images, because images have different conditions such as size, color, brightness, etc. Therefore, in this paper, we propose an algorithm using a modified cascade facial feature point detector using a convolutional neural network. The structure of the convolution neural network is based on LeNet-5 of Yann LeCun. For input data of the convolutional neural network, outputs from a cascade facial feature point detector that have color and gray images were used. The images were resized to $32{\times}32$. In addition, the gray images were made into the YUV format. The gray and color images are the basis for the convolution neural network. Then, we classified about 1,200 testing images that show subjects. This research found that the proposed method is more accurate than a cascade facial feature point detector, because the algorithm provides modified results from the cascade facial feature point detector.

인간의 면역체계 시스템을 적용한 침입 탐지자 생성 모델 (A Model of Applied to Immune System in Intrusion Detector)

  • 신미예;최신형;이상호
    • 중소기업융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.1-6
    • /
    • 2012
  • 본 논문에서는 침입탐지 방법 중 오용탐지모델에서 오용탐지율을 향상시키기 위하여 인간의 면역 시스템을 적용한 탐지자 생성 모델을 제안 한다. DARPA에서 제공된 sendmail 데이터에 대하여 10CV 방법을 이용하였다. 정상적인 시스템 호출을 비정상적인 시스템 호출로 판단하거나 비정상 시스템 호출을 정상적인 시스템 호출로 판단하는 오용 탐지율을 실험하고 분석하였다. 실험에서 임의의 비정상적인 시스템 호출만으로 생성된 탐지자와 임시 탐지자 중에서 정상적인 시스템 호출을 '비정상'이라고 판단하거나 비정상적인 시스템 호출을 '정상'이라고 판단하는 임시 탐지자를 제거한 탐지자를 생성하여 실험하였다. 실험에서 임의의 비정상 시스템 호출만을 탐지자로 선택한 오용탐지율보다 면역 시스템을 적용한 탐지자의 오용 탐지율이 0.3% 향상되었다.

  • PDF

Radar Detector의 국부 발진단에 적용 가늘한 X, K, Ka 대역 L 모양의 소형 Shorted Pin Patch (Compact L Shape Shorted Pin Patch for Local Oscillator Port of X-, K-, Ka-Band Radar Detector)

  • 고승태;김한용;이현택;박재규;이정해
    • 한국전자파학회논문지
    • /
    • 제18권8호
    • /
    • pp.854-861
    • /
    • 2007
  • 본 논문에서는 radar detector에 사용 가능한 국부 발진단용 소형화된 L 모양 shorted pin patch를 제안하였다. Shorted pin patch는 일반적인 구형 patch가 가지는 open-open 공진 형태가 아닌 short-open 공진 형태를 가지고 작동한다. L모양의 shorted pin 배열은 기본 모드(X-band), $2^{nd}\;and\;3^{rd}$ 모드에서 ${\lambda}/4$$3{\lambda}/4$의 공진 구조를 가지게 되어 일반적인 구정 patch보다 소형화가 가능하다 최적화된 L 모양 소정 shorted pin patch는 국부 발진단의 발진 주파수 대역(X, K and Ka band)에서 공진이 일어나 향상된 반사 손실을 가지게 되고, 이에 따라 기존 대비 향상된 radar detector의 감도는 얻을 수 있을 것으로 예상된다.