• Title/Summary/Keyword: Detector

Search Result 6,190, Processing Time 0.03 seconds

Development of Scientific Payloads for Korea Sounding Rocket-III (3단형 과학로켓용 과학탑재체 개발)

  • Hwang, Seung Hyeon;Kim, Jun;Lee, Su Jin;Jeon, Yeong Du;Park, Jeong Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.80-88
    • /
    • 2003
  • This paper describes the development of an ozone detector and an electron probe as parts of scientific payloads for sounding rockets such as the KSR-III. Each detector consists of sensor parts and electronic parts. We successfully carried out the calibration tests with developed ozone detector and the space plasma simulation chamber tests with electron detector. These payloads could be onboard the KSR-III and with measured data, it is expected and temperature profile over the Korean Peninsular.

Implementation of Sound Source Location Detector (음원 위치 검출기의 구현)

  • 이종혁;김진천
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1017-1025
    • /
    • 2000
  • The human auditory system has been shown to posses remarkable abilities in the localization and tracking of sound sources. The localization is the result of processing two primary acoustics cues. These are the interaural time difference(ITD) cues and interaural intensity difference(IID) cues at the two ears. In this paper, we propose TEPILD(Time Energy Previous Integration Location Detector) model. TEPILD model is constructed with time function generator, energy function generator, previous location generator and azimuth detector. Time function generator is to process ITD and energy function generator is to process IID. Total average accuracy rate is 99.2%. These result are encouraging and show that proposed model can be applied to the sound source location detector.

  • PDF

Low Complexity Hybrid Interpolation Algorithm using Weighted Edge Detector (가중치 윤곽선 검출기를 이용한 저 복잡도 하이브리드 보간 알고리듬)

  • Kwon, Hyeok-Jin;Jeon, Gwang-Gil;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3C
    • /
    • pp.241-248
    • /
    • 2007
  • In predictive image coding, a LS (Least Squares)-based adaptive predictor is an efficient method to improve image edge predictions. This paper proposes a hybrid interpolation with weighted edge detector. A hybrid approach of switching between bilinear interpolation and EDI (Edge-Directed Interpolation) is proposed in order to reduce the overall computational complexity The objective and subjective quality is also similar to the bilinear interpolation and EDI. Experimental results demonstrate that this hybrid interpolation method that utilizes a weighted edge detector can achieve reduction in complexity with minimal degradation in the interpolation results.

A Speed-up Method of HOG Pedestrian Detector in Advanced SIMD Architecture (Advanced SIMD 아키텍처에서의 HOG 보행자 검출기 고속화 방법)

  • Kwon, Ki-Pyo;Lee, Jae-Heung
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.106-113
    • /
    • 2014
  • A pedestrian detector can be applied for various purposes such as monitoring or counting the number of people in some place, or detecting the people plunging in the driveway. There was a lot of related research. But, the detection speed is slow in embedded system because of the limited computing power. An algorithm for fast pedestrian detector using HOG in ARM SIMD architecture is presented in this paper. There is a way to quickly remove the background of image and to improve the detection speed using NEON parallel technique. When we tested with INRIA Person Dataset, the proposed pedestrian detector improves the speed by 3.01 times than previous one.

New mathematical approach to calculate the geometrical efficiency using different radioactive sources with gamma-ray cylindrical shape detectors

  • Thabet, Abouzeid A.;Hamzawy, A.;Badawi, Mohamed S.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1271-1276
    • /
    • 2020
  • The geometrical efficiency of a source-to-detector configuration is considered to be necessary in the calculation of the full energy peak efficiency, especially for NaI(Tl) and HPGe gamma-ray spectroscopy detectors. The geometrical efficiency depends on the solid angle subtended by the radioactive sources and the detector surfaces. The present work is basically concerned to establish a new mathematical approach for calculating the solid angle and geometrical efficiency, based on conversion of the geometrical solid angle of a non-axial radioactive point source with respect to a circular surface of the detector to a new equivalent geometry. The equivalent geometry consists of an axial radioactive point source with respect to an arbitrary elliptical surface that lies between the radioactive point source and the circular surface of the detector. This expression was extended to include coaxial radioactive circular disk source. The results were compared with a number of published data to explain how significant this work is in the efficiency calibration procedure for the γ-ray detection systems, especially in case of using isotropic radiating γ-ray sources in the form of point and disk shapes.

Wireless Communication using Millimeter-Wave Envelope Detector (밀리미터파 포락선 검파기를 이용한 무선통신)

  • Lee, Won-Hui;Jang, Sung-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.6
    • /
    • pp.79-82
    • /
    • 2017
  • In this paper, we proposed the wireless communication system using millimeter-wave envelope detector. The sub-harmonic mixer based on schottky barrier diode was used in the transmitter. The receiver was used millimeter-wave envelope detector. The transmitter was composed of schottky diode sub-harmonic mixer, frequency tripler, and horn antenna. The receiver was composed of horn antenna, millimeter-wave envelope detector, low pass filter, base band amplifier, and limiting amplifier. At 1.485 Gbps and 300 GHz, the eye-diagram showed a very good performance as measured by the error free. Communication distance is reduced compared to the heterodyne receiver, but compact and lightweight is possible.

X-ray Sensitivity of Hybrid-type Sensor based on CaWO4-Selenium for Digital X-ray Imager

  • Park, Ji-Koon;Park, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Kim, Jae-Hyung;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.4
    • /
    • pp.133-137
    • /
    • 2004
  • The development of digital x-ray detector has been extensively progressed for the application of various medical modalities. In this study, we introduce a new hybrid-type x-ray detector to improve problems of a conventional direct or indirect digital x-ray image technology, which composed of multi-layer structure using a CaWO$_4$ phosphor and amorphous selenium (a-Se) photoconductor. The leakage current of our detector was found to be ∼180 pA/cm$^2$ at 10 V/m, which was significantly reduced than that of a single a-Se detector. The x-ray sensitivity was measured as the value of 4230 pC/cm$^2$/mR at 10 V/m. We found that the parylene thin film between a CaWO$_4$ phosphor and an a-Se layer acts as an insulator to prevent charge injection from indium thin oxide (ITO) electrode into an a-Se layer under applied bias.

Signal to Noise Improvement in Optical Wireless Interconnection Using A Differential Detector (차동검출기를 이용한 무선광연결에서 신호대잡음비의 개선)

  • 이성호;강희창
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.54-62
    • /
    • 1999
  • In this paper, we investigated the signal-to-noise ratio improvement in a differential detector, which is a function of the optical noise coupling ratio and the differential gain ratio. A differential detector consists of two photodiodes and a differential amplifier. The differential detector reduced the noise component and improved the signal-to-noise ratio by about 20 dB when the differential gain ratio equals to the optical noise coupling ratio. The differential detector is very effective in removing the environmental optical noise or interference from an adjacent optical channel. This method is also effective when the noise wavelength is similar to the signal.

  • PDF

A Study on the Detecting Method for Underground Pipes Using Magnetic Field (자기장을 이용한 매설배관의 위치탐지에 관한 연구)

  • Bae, Bong-Kook;Yang, Yean-Soon;Song, Chun-Ho;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.32-37
    • /
    • 2001
  • As increasing underground facilities, more effective management is needed nowadays. It is important to get an accurate information of underground facilities to manage that, so some methods of detecting location - electromagnetic induction method, ground penetration radar method, sonic method - are used to obtain the information of underground facilities. In this study, a magnetic method to detect underground facilities was developed. In the magnetic method, underground facilities are detected by a detector and the magnetic marker which is a permanent magnet and used to marking the location by attaching underground facilities. A proper characteristic of the magnetic marker was optimized by maxwell 20 magnetic field analysis tool, a test field was constructed with the magnetic marker, PVC pipe, and steel pipe under ground 1.5m, and the detector was made by modifying a common ferromagnetic detector. Magnetic strengths of the magnetic marker were measured by the detector at each location in the test field, and analyzed by magnetic field analysis tool in the same condition. In the result, the underground pipes were detectable within the deviation ${\pm}20cm$ at PVC pipe and ${\pm}10cm$ at steel pipe respectively. The steel pipe was more detectable by ferromagnetism. The developed magnetic method can be applied to maintain and manage underground facilities.

  • PDF

A Study on the Detecting Underground Pipes Using Magnetic Mathod (자기장을 이용한 매설배관의 위치탐지에 관한 연구)

  • 석창성;배봉국;김정표
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.9
    • /
    • pp.63-69
    • /
    • 2003
  • As increasing underground facilities, more effective management is needed nowadays. It is important to get an accurate information of underground facilities to manage that, so some methods of detecting location - electromagnetic induction method, ground penetration radar method, sound wave method - are used to obtain the information of underground facilities. In this study, a magnetic method to detect underground facilities was developed. In the magnetic method, underground facilities are detected by a detector and the magnetic marker which is a permanent magnet and used to marking the location by attaching underground facilities. A test field was constructed for experiment with the magnetic marker, PVC pipe, and steel pipe under ground 1.5m, and a ferromagnetic detector was used for measurement. Magnetic strengths of the magnetic marker were measured by the detector at each location in the test field, and analyzed by magnetic field analysis tool in the same condition. In the result, the underground pipes of 1.5m below were detectable within the deviation $\pm$0.2m. When For applying this method, it should be considered that ferromagnetic materials around the detector could affect a measured value.