• Title/Summary/Keyword: Detector

Search Result 6,190, Processing Time 0.03 seconds

An Improvement on the Self Diagnostic Characteristics of the Triple Quard Channel Infrared Flame Detector (삼파장 4채널 적외선식 불꽃감지기의 자가진단 성능 개선)

  • Song, Hyun Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.49-54
    • /
    • 2016
  • There is needed the quard channel triple wave lengths pyroelectric infrared flame detector to recognize the unique characteristics of fire sources in various type. This system detects the triple wave lengths of infrared flame emitting maximum radient energy and scattering frequency of flame. The quard channel infrared flame detector detects the duplicate wave lengths of maximum radient energy to enhance the accuracy of detecting fire. Especially this paper focuss on development of the self diagnosis function system including contamination, temperature and input voltage. Therefore, the prevention and early suppression of fire is available.

Development of Individual Trespassing Detector for Building (개체 독립형 건축물 침입감지기 개발)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.400-403
    • /
    • 2008
  • In this work, an individual trespassing detector using a PIR sensor to detect infrared rays only between the range of $9.4{\sim}10.4{\mu}m$ radiated from the body is proposed. This detector using FIR sensor detects not insect or object but human body, It doesn't restrict the inhabitant's behavior because the filter of pm sensor is designed to have face angle and the detector only detects the window area. The existing wide angle filter, RIR sensor, detects $30^{\circ}$ angle while the face angle filter sensor on this paper detects $11^{\circ}$ angle with 3cm of face angle filter from 2m of detecting distance. In case of interruption of electric power, 250mAh of lithium-ion battery has worked for 10 hours consuming 22mA in normal state. Meanwhile, in case of interruption of electric power, 250mAh of battery has worked for 4 hours consuming 60mA in trespassing detecting state. Projector, receptor, controller and alarm are put on one PCB in order to make it convenient to install without any special installation skill.

The n-p-n-p layer stacked color detector for CMOS image sensor (CMOS 이미지 센서용 n-p-n-p 적층형 색 검출기)

  • Song, Young-Sun;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.72-73
    • /
    • 2005
  • In this paper, the simulation of the n-p-n-p layer stacked color detector is presented. A color detector based on vertically integrated structures of silicon can overcome color moire or color aliasing effect. The color detector is designed to separate the fundamental chromatic components at each junction and exhibits maxima of the spectral sensitivity at red, green, and blue region, respectively. From this result, it is observed that the spectral response can be controlled by the doping concentration and structure of the devices.

  • PDF

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

Detector Foil Self-Shielding Correction Factors

  • Kwon, Oh-Sun;Kim, Bong-Ghi;Suk, Ho-Chun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.197-201
    • /
    • 1996
  • In the detail reaction-rate measurements in a critical assembly using the foil activation method, the measured activations of detector foils have inevitably errors caused by detector foil self-shielding effect. If neutron flux could be approximated to Westcott flux: i.e. well thermalized Maxwellian distribution, these activations of detector foil could be corrected to represent the unperturbated flux at any detected position in the cell with using Westcott option and reaction-rate option of the lattice code, WIMS-AECL. These calculated detector material self-shielding correction factors of the tested fuel, CANFLEX provided much information about neutron spectrum of test lattice cell as well as the correction factors themselves. The results could be verified by another lattice calculations.

  • PDF

Performance Analysis of Detector in Automobile Pulse Radar with Considering Interference (차량용 펄스 레이더에서 간섭영향에 대한 검출기의 성능 분석)

  • Lee, Jonghun;Ko, Seokjun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2019
  • In this paper, we consider interferences from other automobile pulse radars using same frequency spectrum. In order to eliminate the interference, we propose the PN code modulation method. This method uses the cross-correlation between PN codes with different seed. The ROC performance is used for comparing the proposed detector to conventional method. And the proposed detector can decide the present or absent of targets and measure the range of the targets by using memory buffer of range gate. Especially, we use false alarm probability for all range gates. That is the false alarm if in any one range gate the false alarm occurs. From the simulation result, we can see that the proposed detector with using PN code is not influenced by interferences.

Advanced Energy Detector with Correlated Multiple Antennas

  • Kim, Sungtae;Lim, Sungmook
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.12
    • /
    • pp.4600-4616
    • /
    • 2021
  • In cognitive radio networks where unlicensed secondary users opportunistically access to licensed spectrum unused by licensed primary users, spectrum sensing is one of the key issues in order to effectively use the frequency resource. For enhancing the sensing performance in energy detection-based spectrum sensing, spatial diversity based on multiple antennas is utilized. However, the sensing performance can be degraded when antennas are spatially correlated, resulting in inducing the harmful interference to primary users. To overcome this problem, in this paper, an advanced energy detector is proposed. In the proposed sensing method, a weight matrix based on the eigenvalues of the spatial channels without any prior information on the primary signals is defined and utilized. In numerical simulations, it is shown that the proposed detector outperforms the conventional detector with regard to false-alarm and detection probabilities when antenna are spatially correlated.

Implementation of a Real-time SIFT Pitch Detector (실시간 SIFT 기본주파수 검출기의 구현)

  • Lee, Jong Seok;Lee, Sang Uk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.1
    • /
    • pp.101-113
    • /
    • 1986
  • In this paper, a real-time pitch detector LPC vocoder as implemented on a high speed digital signal processor, NEC 7720, is described. The pitch detector was based mainly on the SIFT algorithm. The SIFT pitch detector consists primarily of a digital low pass filter, inverse filter, computation of autocorrelation, a peak picker, interpolation, V/UV defcision and a final pitch smoother. In our approach, modification, mainly on the V/UV decision and a final pitch smoother, was made to estimate more accurate pitches. An 16-bit fixed-point aithmatic was employed for all necessary computation and the simulated results were compared with the eye detected pitches obtained from real speech data. The pitch detector occupies 98.8% of the instruction ROM, 37% of the data ROM, and 94% of internal RAM and takes 15.2ms to estimate a pitch when an analysis frame is consisted of 128 sampled speech data. It is observed that the tested results were well agreed with the computer simulation results.

  • PDF

Research of Efficiency for Gas Electron Multiplier Detector to Monitor Low Energy Gamma-Ray and Beta-Ray (낮은 에너지 감마선과 베타선 모니터링을 위한 Gas Electron Multiplier 검출기의 효율성에 대한 연구)

  • Lee, Soonhyouk;Jung, Jae Hoon;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.95-99
    • /
    • 2014
  • Radiation monitoring is one of the most important process in all places where radioactive material is used including hospital. In this preliminary study, we made GAS electron multiplier (GEM) detector and acquired relative efficiencies in order to see if GEM detector can be useful in radiation monitoring system. The relative efficiency was acquired by using the ratio of GEM detector efficiency to CdTe detector efficiency. The relative efficiency of 72% and 4% was acquired for beta-ray and gamma-ray respectively.

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF