• 제목/요약/키워드: Detection loss

검색결과 932건 처리시간 0.027초

Vibration and impedance monitoring for prestress-loss prediction in PSC girder bridges

  • Kim, Jeong-Tae;Park, Jae-Hyung;Hong, Dong-Soo;Cho, Hyun-Man;Na, Won-Bae;Yi, Jin-Hak
    • Smart Structures and Systems
    • /
    • 제5권1호
    • /
    • pp.81-94
    • /
    • 2009
  • A vibration-impedance-based monitoring method is proposed to predict the loss of prestress forces in prestressed concrete (PSC) girder bridges. Firstly, a global damage alarming algorithm using the change in frequency responses is formulated to detect the occurrence of damage in PSC girders. Secondly, a local damage detection algorithm using the change in electro-mechanical impedance features is selected to identify the prestress-loss in tendon and anchoring members. Thirdly, a prestress-loss prediction algorithm using the change in natural frequencies is selected to estimate the extent of prestress-loss in PSC girders. Finally, the feasibility of the proposed method is experimentally evaluated on a scaled PSC girder model for which acceleration responses and electro-mechanical impedances were measured for several damage scenarios of prestress-loss.

트랜스포머 기반 판별 특징 학습 비전을 통한 얼굴 조작 감지 (Facial Manipulation Detection with Transformer-based Discriminative Features Learning Vision)

  • ;김민수;최필주;이석환;;권기룡
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.540-542
    • /
    • 2023
  • Due to the serious issues posed by facial manipulation technologies, many researchers are becoming increasingly interested in the identification of face forgeries. The majority of existing face forgery detection methods leverage powerful data adaptation ability of neural network to derive distinguishing traits. These deep learning-based detection methods frequently treat the detection of fake faces as a binary classification problem and employ softmax loss to track CNN network training. However, acquired traits observed by softmax loss are insufficient for discriminating. To get over these limitations, in this study, we introduce a novel discriminative feature learning based on Vision Transformer architecture. Additionally, a separation-center loss is created to simply compress intra-class variation of original faces while enhancing inter-class differences in the embedding space.

Evaluation of nuclear material accountability by the probability of detection for loss of Pu (LOPu) scenarios in pyroprocessing

  • Woo, Seung Min;Chirayath, Sunil S.
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.198-206
    • /
    • 2019
  • A new methodology to analyze the nuclear material accountability for pyroprocessing system is developed. The $Pu-to-^{244}Cm$ ratio quantification is one of the methods for Pu accountancy in pyroprocessing. However, an uncertainty in the $Pu-to-^{244}Cm$ ratio due to the non-uniform composition in used fuel assemblies can affect the accountancy of Pu. A random variable, LOPu, is developed to analyze the probability of detection for Pu diversion of hypothetical scenarios at a pyroprocessing facility considering the uncertainty in $Pu-to-^{244}Cm$ ratio estimation. The analysis is carried out by the hypothesis testing and the event tree method. The probability of detection for diversion of 8 kg Pu is found to be less than 95% if a large size granule consisting of small size particles gets sampled for measurements. To increase the probability of detection more than 95%, first, a new Material Balance Area (MBA) structure consisting of more number of Key Measurement Points (KMPs) is designed. This multiple KMP-measurement for the MBA shows the probability of detection for 8 kg Pu diversion is greater than 96%. Increasing the granule sample number from one to ten also shows the probability of detection is greater than 95% in the most ranges for granule and powder sizes.

Arc Detection System using a Spectrometer for Status Monitoring of a Rigid Catenary

  • Jung, No-Geon;Kim, Jae-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2419-2425
    • /
    • 2017
  • In this paper, a system for the precise detection of arcs is proposed for a rigid catenary using a spectrometer. For this purpose, a miniature rigid catenary contact-loss simulator was used. Experiments were performed by varying the amplitude of the excitation frequency with which a real arc can occur using a simulator in the range of 5 to 15 mm. The range of the radiated wavelength of the copper, which is a material in the rigid catenary, and the irradiance were measured using a spectrometer according to the generated contact loss. In addition, the amount was monitored over time and its characteristics were analyzed. The voltage and current of the load were analyzed when the arc occurred due to contact loss. The analytical results will be applied to detect rigid catenary arcs and used as a monitoring system for real vehicles developed in the future. This will prevent abrasion and disconnection in rigid catenary systems.

PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage

  • Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • 제22권1호
    • /
    • pp.57-70
    • /
    • 2018
  • For the long-term structural health monitoring of civil structures, the effect of ambient temperature variation has been regarded as one of the critical issues. In this study, a principal component analysis (PCA)-based algorithm is proposed to filter out temperature effects on electromechanical impedance (EMI) monitoring of prestressed tendon anchorages. Firstly, the EMI monitoring via a piezoelectric interface device is described for prestress-loss detection in the tendon anchorage system. Secondly, the PCA-based temperature filtering algorithm tailored to the EMI monitoring of the prestressed tendon anchorage is outlined. The proposed algorithm utilizes the damage-sensitive features obtained from sub-ranges of the EMI data to establish the PCA-based filter model. Finally, the feasibility of the PCA-based algorithm is experimentally evaluated by distinguishing temperature changes from prestress-loss events in a prestressed concrete girder. The accuracy of the prestress-loss detection results is discussed with respect to the EMI features before and after the temperature filtering.

청력손실과 보청기 조절 오류의 발견 지연 1례 보고 (A Case Report of Delayed Identification of Hearing Loss and Hearing Aid Fitting Failure)

  • 허승덕
    • 재활복지공학회논문지
    • /
    • 제11권3호
    • /
    • pp.215-221
    • /
    • 2017
  • 청각학적 재활은 청력손실 배경 정보 획득, 청각학적 평가, 보청기 전기음향특성 분석, 음향 이득 결정만으로도 충분히 만족스러운 서비스를 제공할 수 있다. 그러나 청력은 나빠질 수 있고, 보청기는 출력음압이 낮아지거나 고장이 발생할 수도 있다. 따라서 청력손실의 조기 발견과 정기적인 추적 관찰은 매우 중요하다. 이 연구는 정상적인 추적에도 불구하고 보청기 조절 실수가 확인된 증례를 통해 효과적인 청각언어재활 방향을 고민하는데 목적이 있다.

The Study of CFAR(Constant False Alarm Rate) process for a helicopter mounted millimeter wave radar system

  • Kim In Kyu;Moon Sang Man;Kim Hyoun Kyoung;Lee Sang Jong;Kim Tae Sik;Lee Hae Chang
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.890-895
    • /
    • 2004
  • This paper describes constant alarm rates process of millimeter wave radar that exits on non-stationary target detection schemes in the ground clutter conditions. The comparison of various CFAR processes such as CA(Cell-Average)-CFAR, GO(Greatest Of)/SO(Smallest Of)-CFAR and OS(Order Statistics)-CFAR performance are applied. Using matlab software, we show the performance and loss between detection probability and signal to noise ratio. When rang bins increase, this results show the OS-CFAR process performance is better than any others and satisfies the optimal detection probability without loss of detection in the homogeneous clutter.

  • PDF

Quasi-Distributed Water Detection Sensor Based On a V-Grooved Single-Mode Optical Fiber Covered with Water-Soluble Index-Matched Medium

  • Kim, Dae Hyun;Kim, Kwang Taek
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.1-5
    • /
    • 2015
  • The V-grooved single-mode fiber in which a surface part of the core was removed was investigated as a quasi-distributed water detection sensor. In the normal state, the V-grooved region is filled and covered with a specific RI (Refractive Index)-matched medium, and the sensor experiences minimal optical loss. As water invades the V-grooved region, the material is dissolved and removed, and a considerable optical loss occurs owing to the large RI difference between the fiber core and water. The experimental results showed the feasibility of the device as a sensor element of the quasi-distributed water detection sensor system based on general optical time domain reflectometry (OTDR).

Islanding Detection for Distributed Generation

  • Ding, X.;Crossley, P.A.;Morrow, D.J.
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.19-28
    • /
    • 2007
  • The paper discussed various techniques for islanding detection and described in detail the working principles of ROCOF and vector shift relays. A simulator was used to investigate why the stability of both types of relays maybe affected by network and load switching, short-circuit faults and in the case of a ROCOF relay the loss of bulk generation or the tripping of a transmission feeder. Finally, to enhance the reliability of Loss of Mains protection, a new islanding detection technique based on a GPS synchronized phasor measurement system was proposed.

온실가스 기기분석의 정도관리를 위한 고려사항 연구 - CH4과 CO2를 중심으로 - (Some Insights into the Basic QA/QC for the Greenhouse Gas Analysis: Methane and Carbon Dioxide)

  • 정재학;임호수;김기현;배위섭;전의찬
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.712-718
    • /
    • 2006
  • In order to investigate the analytical uncertainties associated with sampling and analysis of major greenhouse gaseous pollutants(carbon dioxide and methane), we attempted to quantify their adsorptive loss due to the contact with the container wall(such as Tedlar bag and vial). Using the GC/FID method, some basic experimental parameters(such as reproducibility and method detection limit) have been evaluated as part of the essential QA/QC The reproducibilities of carbon dioxide and methane were estimated as 2.02 and 0.2%, respectively. In addition, method detection limits were measured as 0.61 and 0.06 ng, respectively. A test of sample loss rate has also been made for Tedlar bag and vial by assessing the absolute amount of sample loss on the wall. By transferring the samples contained in Tedlar bag to various sizes of Tedlar bags, we measured differences in the absolute loss quantity due to such transfer. In addition, we also examined such loss mechanism as a function of elapsed time and light penetration rate for vial. As results, carbon dioxide and methane have shown about 2% of sample loss due to such contact. It is also noticed that the amount of loss with vial surface is lower than that of Tedlar bag. Therefore, field collection of greenhouse gases using various container types should be made more cautiously to minimize the possibility of sample loss and bias related to such loss.