• Title/Summary/Keyword: Detection limits

Search Result 940, Processing Time 0.034 seconds

Development of HPLC Method for Quality Assessment of Marker Components in Atractylodis Rhizoma Alba (백출(Atractylodis Rhizoma Alba)의 품질평가를 위한 지표성분 분석법 평가)

  • Lee, Jae-Woong;Kim, Joon-Hee;Kang, Byoung-Man;Ahn, Byung-Kwan
    • Korean Journal of Plant Resources
    • /
    • v.34 no.1
    • /
    • pp.52-58
    • /
    • 2021
  • Homogenization of quality was important in order to use herbal medicines as pharmaceuticals. To solve this problem, it was important to establish quality standards. Atractylodis Rhizoma Alba has no quantitative method in the Korean Pharmacopoeia. Thus, we have researched to improve the quality evaluation method of Atractylodis Rhizoma Alba with an HPLC. Atractylenolide III and atracylodin were selected as potential marker compounds. This analytical procedure was subject to validation. According to validation guideline of South Korea's Ministry of Food and Drugs Safety, the specificity, linearity, precision, range, quantitative limits, detection limits and accuracy were measured. Because the specificity, linearity, precision, range, quantitative limits, detection limits and accuracy meet criteria of the guideline, the analytic method was validated. With this analysis, Atractylodis Rhizoma Alba and Atractylodis Rhizoma analyzed. As a result, both atractylenolide III and atracylodin appear to be suitable standard compounds. it confirmed that tractylodes Rhizome, similar to Atractylodes Rhizome Alba, could be distinguished.

A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants (석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구)

  • Eun-Seung Lee;Yun-Keun Lee;Dong-Il Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

Monitoring for β-agonist residues in raw meat in Seoul (식육에서 베타아고니스트계 약물 잔류 연구)

  • Choi, Yoon-Hwa;Kim, Mi-Ran;Kim, Young-Seob;Lee, Ju-Hyeong
    • Korean Journal of Veterinary Service
    • /
    • v.40 no.1
    • /
    • pp.79-82
    • /
    • 2017
  • We investigated the residues of ${\beta}-agonist$ (zilpaterol, ractopamine and clenbuterol) using LC-MS/MS in raw meat in Seoul. The recoveries ranged between 76.7~89.9% in beef respectively. The limits of detection were $0.01{\sim}0.09{\mu}g/kg$ and the limits of quantification were $0.03{\sim}0.28{\mu}g/kg$ respectively. Residues of ${\beta}-agonist$ drugs which exceeded maximum residue limits (MRL) were not exceed in any of the 267 samples.

Analysis of Performance employing Chromatic Dispersion in Millimeter-wave Links (밀리미터파 대역 링크에서 색 분산에 의한 성능 분석)

  • 김정태
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.309-312
    • /
    • 2000
  • In this paper, The Influence of chromatic fiber dispersion on the transmission distance of MMW(millimeter-wave) link is analyzed and discussed. It is shown that dispersion significantly limits the transmission distance in intensity modulated direct detection and heterodyne links operating in the above 20㎓ frequency region by inducing a carrier to noise penalty on the transmitted signal. We analyze and discuss the influence of dispersion induced CNR(Carrier to Noise Ratio) penalty for direct detection and heterodyne method from simulation.

  • PDF

Development of a Multiplex Reverse Transcription-Polymerase Chain Reaction Assay for the Simultaneous Detection of Three Viruses in Leguminous Plants

  • Park, Chung Youl;Min, Hyun-Geun;Lee, Hong-Kyu;Maharjan, Rameswor;Yoon, Youngnam;Lee, Su-Heon
    • Research in Plant Disease
    • /
    • v.24 no.4
    • /
    • pp.348-352
    • /
    • 2018
  • A multiplex reverse transcription-polymerase chain reaction (mRT-PCR) assay was developed for the detection of Clover yellow vein virus (ClYVV), Peanut mottle virus (PeMoV), and Tomato spotted wilt virus (TSWV), which were recently reported to infect soybean and azuki bean in Korea. Species-specific primer sets were designed for the detection of each virus, and their specificity and sensitivity were tested using mixed primer sets. From among the designed primer sets, two combinations were selected and further evaluated to estimate the detection limits of uniplex, duplex, and multiplex RT-PCR. The multiplex RT-PCR assay could be a useful tool for the field survey of plant viruses and the rapid detection of ClYVV, PeMoV, and TSWV in leguminous plants.

Analytical Characteristics of GC/MS and HPLC according to the Concentration Distribution of PAHs (PAHs 농도 분포에 따른 GC/MS와 HPLC의 분석특성에 관한 연구)

  • Hong, Jwa-Ryung;Choi, Kwang-Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.312-321
    • /
    • 2015
  • Objectives: The purpose of this study was to determine the best method to analyze PAHs at extremely low concentrations. To this end, 16 PAHswere analyzed simultaneously by GC/MS, HPLC/FLD and HPLC/UVD, and the analytical characteristics of HPLC and GC/MS were compared. Methods: This study was conducted by GC/MS and HPLC/FLD/UVD, and evaluated linearity, precision and detection limit. Standard solutions were prepared for 21 samples in the range of $0.00001{\sim}1.0{\mu}g/mL$ and the samples were divided into four groups. All samples were made in three sets and analysis was replicated seven times. Results: Sixteen PAHs could be simultaneously separated by HPLC and GC/MS, and the adequate equipment was HPLC/FLD. The retention times by HPLC were shorter than GC/MS, and HPLC had better separation for most PAHs than GC/MS. The peaks of naphthalene and naphthalene-D8 partially overlapped for GC/MS. HPLC/FLD had a 20-2000 times lower limit of detection than GC/MS and UVD. However FLD was not adequate for analyzing acenaphthylene because it has too low a fluorescence quantum yield to be detected. The precision of HPLC/FLD/UVD and GC/MS showed less than 20% at $0.001{\mu}g/mL$ PAHs and when the concentration was higher, the coefficient of variation was decreased. HPLC/FLD was better for the overall detection of limits. Conclusions: The results indicate that the HPLC/FLD method has good linear range, precision and a detection of limits from $0.00001{\sim}0.0001{\mu}g/mL$ for all 16 PAHs. This study contributes to providing useful data for analysis technology and can be applied to occupational exposure measurement for PAHs in workplaces.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Monitoring of Carbamate Pesticide Residues in Agricultural Products Supplied for the Army (군납 농산물 중 카바메이트계 농약의 모니터링)

  • Park, Jong-Ko;Na, Jk-Ju
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.4
    • /
    • pp.266-271
    • /
    • 2006
  • This study was monitored for 14 pesticide residues in agricultural products for the army, such as fruit vegetables(pepper, cucumber, pumpkin, melon and water melon), leafy vegetables(Korean cabbage, spinach, lettuce, crown daisy, cabbage, green onion), mushrooms(agaric, p'yogo), and bean sprouts produced in Kyunggi-do and Inchon-City. From January to December 2005, ten carbamate pesticides in 356 samples were analyzed by HPLC. One kind of pesticide was detected in 8 samples of detection rate (2.53%), and two pesticides were in one sample of detection rate(0.27%). Aldicarb, bendiocarb, fenobucarb, methiocarb, isoprocarb, and propoxur were not found in all samples. Detection rates of pesticides were 0.84% for methomyl, 0.56% for carbofuran, 0.56% for ethiofencarb, and 0.28% for carbayl. Dectection ranges of pesticides were from 0.01 to 2.9 mg/kg for ethiofencarb, from 0.1 to 0.23 mg/kg for methomyl, from 0.20 to 0.24 mg/kg for carbofuran, and 0.01 mg/kg for carbaryl, respectively. Consequently, detection levels of all pesticides in samples were less than the maximum residue limits(MRLs) in Korea representing that all agricultural products for the army were safe.

Radiation Detection System for Prevention of Illicit Trafficking of Nuclear and Radioactive Materials

  • Kwak, Sung-Woo;Chang, Sung-Soon;Yoo, Ho-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.4
    • /
    • pp.167-171
    • /
    • 2010
  • Fixed radiation portal monitors (RPMs) deployed at border, seaport, airport and key traffic checkpoints have played an important role in preventing the illicit trafficking and transport of nuclear and radioactive materials. However, the RPM is usually large and heavy and can't easily be moved to different locations. These reasons motivate us to develop a mobile radiation detection system. The objective of this paper is to report our experience on developing the mobile radiation detection system for search and detection of nuclear and radioactive materials during road transport. Field tests to characterize the developed detection system were performed at various speeds and distances between the radioactive isotope (RI) transporting car and the measurement car. Results of measurements and detection limits of our system are described in this paper. The mobile radiation detection system developed should contribute to defending public's health and safety and the environment against nuclear and radiological terrorism by detecting nuclear or radioactive material hidden illegally in a vehicle.